Does Use of a Powered Ankle-foot Prosthesis Restore Whole-body Angular Momentum During Walking at Different Speeds?

被引:34
|
作者
D'Andrea, Susan [1 ]
Wilhelm, Natalie [1 ]
Silverman, Anne K. [2 ]
Grabowski, Alena M. [3 ,4 ]
机构
[1] Providence VA Med Ctr, Dept Vet Affairs, Providence, RI USA
[2] Colorado Sch Mines, Golden, CO 80401 USA
[3] Univ Colorado, Boulder, CO 80309 USA
[4] Eastern Colorado Healthcare Syst, Dept Vet Affairs, Denver, CO USA
关键词
GAIT;
D O I
10.1007/s11999-014-3647-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Whole-body angular momentum (H) influences fall risk, is tightly regulated during walking, and is primarily controlled by muscle force generation. People with transtibial amputations using passive-elastic prostheses typically have greater H compared with nonamputees. (1) Do people with unilateral transtibial amputations using passive-elastic prostheses have greater sagittal and frontal plane H ranges of motion during walking compared with nonamputees and compared with using powered prostheses? (2) Does use of powered ankle-foot prostheses result in equivalent H ranges in all planes of motion compared with nonamputees during walking as a result of normative prosthetic ankle power generation? Eight patients with a unilateral transtibial amputation and eight nonamputees walked 0.75, 1.00, 1.25, 1.50, and 1.75 m/s while we measured kinematics and ground reaction forces. We calculated H for participants using their passive-elastic prosthesis and a powered ankle-foot prosthesis and for nonamputees at each speed. Patients using passive-elastic prostheses had 32% to 59% greater sagittal H ranges during the affected leg stance phase compared with nonamputees at 1.00 to 1.75 m/s (p < 0.05). Patients using passive-elastic prostheses had 5% and 9% greater sagittal H ranges compared with using powered prostheses at 1.25 and 1.50 m/s, respectively (p < 0.05). Participants using passive-elastic prostheses had 29% and 17% greater frontal H ranges at 0.75 and 1.50 m/s, respectively, compared with nonamputees (p < 0.05). Surprisingly, patients using powered prostheses had 26% to 50% greater sagittal H ranges during the affected leg stance phase compared with nonamputees at 1.00 to 1.75 m/s (p < 0.05). Patients using powered prostheses also had 26% greater frontal H range compared with nonamputees at 0.75 m/s (p < 0.05). People with a transtibial amputation may more effectively regulate H at two specific walking speeds when using powered compared with passive-elastic prostheses. Our results support the hypothesis that an ankle-foot prosthesis capable of providing net positive work during the stance phase of walking reduces sagittal plane H; future studies are needed to validate our biomechanical findings with larger numbers of patients and should determine whether powered prostheses can decrease the risk of falls in patients with a transtibial amputation.
引用
收藏
页码:3044 / 3054
页数:11
相关论文
共 50 条
  • [41] The influence of the use of ankle-foot orthoses on thorax, spine, and pelvis kinematics during walking in children with cerebral palsy
    Swinnen, Eva
    Baeyens, Jean-Pierre
    Van Mulders, Benjamin
    Verspecht, Julian
    Degelaen, Marc
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2018, 42 (02) : 208 - 213
  • [42] Segmental contribution to whole-body angular momentum during stepping in healthy young and old adults
    Begue, Jeremie
    Peyrot, Nicolas
    Lesport, Angelique
    Turpin, Nicolas A.
    Watier, Bruno
    Dalleau, Georges
    Caderby, Teddy
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [43] Whole-body angular momentum during stair ascent and descent in individuals with and without knee osteoarthritis
    Chan, Daisy O. M.
    Arachchige, Ransi S. S. Subasinghe
    Wang, Sizhong
    Chan, Peter P. K.
    Cheung, Roy T. H.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [44] Segmental contribution to whole-body angular momentum during stepping in healthy young and old adults
    Jérémie Begue
    Nicolas Peyrot
    Angélique Lesport
    Nicolas A. Turpin
    Bruno Watier
    Georges Dalleau
    Teddy Caderby
    Scientific Reports, 11
  • [45] Recovering whole-body angular momentum and margin of stability after treadmill-induced perturbations during sloped walking in healthy young adults
    Shokouhi, Shabnam
    Sritharan, Prasanna
    Lee, Peter Vee-Sin
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [46] Recovering whole-body angular momentum and margin of stability after treadmill-induced perturbations during sloped walking in healthy young adults
    Shabnam Shokouhi
    Prasanna Sritharan
    Peter Vee-Sin Lee
    Scientific Reports, 14
  • [47] Human Gait During Level Walking With an occupational Whole-Body Powered Exoskeleton: Not Yet a Walk in the Park
    Kim, Sunwook
    Srinivasan, Divya
    Nussbaum, Maury A.
    Leonessa, Alexander
    IEEE ACCESS, 2021, 9 : 47901 - 47911
  • [48] Transtibial prosthetic alignment has small effects on whole-body angular momentum during functional tasks
    Nolasco, Luis A.
    Silverman, Anne K.
    Gates, Deanna H.
    JOURNAL OF BIOMECHANICS, 2023, 149
  • [49] Once-per-step control of ankle-foot prosthesis push-off work reduces effort associated with balance during walking
    Kim, Myunghee
    Collins, Steven H.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2015, 12
  • [50] Once-per-step control of ankle-foot prosthesis push-off work reduces effort associated with balance during walking
    Myunghee Kim
    Steven H Collins
    Journal of NeuroEngineering and Rehabilitation, 12