Does Use of a Powered Ankle-foot Prosthesis Restore Whole-body Angular Momentum During Walking at Different Speeds?

被引:34
|
作者
D'Andrea, Susan [1 ]
Wilhelm, Natalie [1 ]
Silverman, Anne K. [2 ]
Grabowski, Alena M. [3 ,4 ]
机构
[1] Providence VA Med Ctr, Dept Vet Affairs, Providence, RI USA
[2] Colorado Sch Mines, Golden, CO 80401 USA
[3] Univ Colorado, Boulder, CO 80309 USA
[4] Eastern Colorado Healthcare Syst, Dept Vet Affairs, Denver, CO USA
关键词
GAIT;
D O I
10.1007/s11999-014-3647-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Whole-body angular momentum (H) influences fall risk, is tightly regulated during walking, and is primarily controlled by muscle force generation. People with transtibial amputations using passive-elastic prostheses typically have greater H compared with nonamputees. (1) Do people with unilateral transtibial amputations using passive-elastic prostheses have greater sagittal and frontal plane H ranges of motion during walking compared with nonamputees and compared with using powered prostheses? (2) Does use of powered ankle-foot prostheses result in equivalent H ranges in all planes of motion compared with nonamputees during walking as a result of normative prosthetic ankle power generation? Eight patients with a unilateral transtibial amputation and eight nonamputees walked 0.75, 1.00, 1.25, 1.50, and 1.75 m/s while we measured kinematics and ground reaction forces. We calculated H for participants using their passive-elastic prosthesis and a powered ankle-foot prosthesis and for nonamputees at each speed. Patients using passive-elastic prostheses had 32% to 59% greater sagittal H ranges during the affected leg stance phase compared with nonamputees at 1.00 to 1.75 m/s (p < 0.05). Patients using passive-elastic prostheses had 5% and 9% greater sagittal H ranges compared with using powered prostheses at 1.25 and 1.50 m/s, respectively (p < 0.05). Participants using passive-elastic prostheses had 29% and 17% greater frontal H ranges at 0.75 and 1.50 m/s, respectively, compared with nonamputees (p < 0.05). Surprisingly, patients using powered prostheses had 26% to 50% greater sagittal H ranges during the affected leg stance phase compared with nonamputees at 1.00 to 1.75 m/s (p < 0.05). Patients using powered prostheses also had 26% greater frontal H range compared with nonamputees at 0.75 m/s (p < 0.05). People with a transtibial amputation may more effectively regulate H at two specific walking speeds when using powered compared with passive-elastic prostheses. Our results support the hypothesis that an ankle-foot prosthesis capable of providing net positive work during the stance phase of walking reduces sagittal plane H; future studies are needed to validate our biomechanical findings with larger numbers of patients and should determine whether powered prostheses can decrease the risk of falls in patients with a transtibial amputation.
引用
收藏
页码:3044 / 3054
页数:11
相关论文
共 50 条
  • [21] Analysis of the Ankle Moment-Angle Curve in Different Gait Speeds and Phases for Designing Ankle-Foot Prosthesis
    Safaa'eepour, Z.
    Esteki, A.
    Ghomsheh, Tabataba'ei F.
    Mousavi, M., I
    ARCHIVES OF REHABILITATION, 2014, 14 (04): : 90 - 98
  • [22] Effect of perturbation timing on recovering whole-body angular momentum during very slow walking
    van Mierlo, M.
    Abma, M.
    Vlutters, M.
    van Asseldonk, E. H. F.
    van der Kooij, H.
    HUMAN MOVEMENT SCIENCE, 2023, 91
  • [23] A Powered Ankle-Foot Prosthesis with a Neuromuscular Based Control Algorithm can Successfully Mimic Human Walking.
    Hessel, A. L.
    Tahir, U.
    Petak, J. L.
    Lemoyne, R. C.
    Tester, J.
    Nishikawa, K. C.
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2015, 55 : E274 - E274
  • [24] Use of a powered ankle-foot prosthesis reduces the metabolic cost of uphill walking and improves leg work symmetry in people with transtibial amputations
    Montgomery, Jana R.
    Grabowski, Alena M.
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2018, 15 (145)
  • [25] Whole-body angular momentum during stair ascent and descent
    Silverman, Anne K.
    Neptune, Richard R.
    Sinitski, Emily H.
    Wilken, Jason M.
    GAIT & POSTURE, 2014, 39 (04) : 1109 - 1114
  • [26] Differences in whole-body angular momentum between below-knee amputees and non-amputees across walking speeds
    Silverman, A. K.
    Neptune, R. R.
    JOURNAL OF BIOMECHANICS, 2011, 44 (03) : 379 - 385
  • [27] VARIATION OF WHOLE-BODY ANGULAR AND LINEAR MOMENTUM DURING HUMAN LOCOMOTION
    Jackson, Jennifer N.
    Hass, Chris J.
    De Witt, John K.
    Walter, Jonathan P.
    Fregly, Benjamin J.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 447 - 448
  • [28] Foot/ankle roll-over characteristics for different joint alignments of the ankle-foot orthosis (AFO) during level walking
    Choi, Hueseok
    Kim, Youngho
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 872 - +
  • [29] Effect of increasing speed on whole-body angular momentum during stepping in the elderly
    Begue, Jeremie
    Peyrot, Nicolas
    Dalleau, Georges
    Caderby, Teddy
    JOURNAL OF BIOMECHANICS, 2021, 122
  • [30] Whole-body and segment angular momentum during 90-degree turns
    Nolasco, Luis A.
    Silverman, Anne K.
    Gates, Deanna H.
    GAIT & POSTURE, 2019, 70 : 12 - 19