Overestimation of carotid artery stenosis with magnetic resonance angiography compared with digital subtraction angiography

被引:51
|
作者
Nederkoorn, PJ
Elgersma, OEH
Mali, WPTM
Eikelboom, BC
Kappelle, LJ
van der Graaf, Y
机构
[1] Univ Utrecht, Med Ctr, Julius Ctr Patient Oriented Res, NL-3508 GA Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[3] Univ Utrecht, Med Ctr, Dept Vasc Surg, NL-3508 GA Utrecht, Netherlands
[4] Univ Utrecht, Med Ctr, Dept Neurol, NL-3508 GA Utrecht, Netherlands
关键词
D O I
10.1067/mva.2002.127529
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background and purpose: Three-dimensional time-of-flight (3D TOF) magnetic resonance angiography (MRA) is generally considered to overestimate the degree of stenosis in the internal carotid artery (ICA) in comparison with the reference standard intraarterial digital subtraction angiography (DSA). We evaluated whether the degree of stenosis was more accurately assessed with 3D TOF MRA if corresponding projections on MRA and DSA were compared instead of comparison of maximal stenosis at MRA with maximal stenosis at DSA. Methods: From February 1997 to December 1999, we included 186 symptomatic and 17 asymptomatic consecutive patients suspected of having carotid artery stenosis on the basis of clinical presentation and screening with duplex ultrasound scan examination. All patients subsequently underwent DSA and MRA imaging. From each ICA, 12 maximum intensity projections with 3D TOF MRA and two or three projections with DSA were obtained. First, we compared the maximal stenosis at MRA with the maximal stenosis at DSA. Subsequently, we used the stenosis at MRA measured on the projection corresponding with the DSA projection that showed the maximal stenosis. For both strategies, the mean differences in stenosis and sensitivity and specificity for assessment of severe stenosis (70% to 99%) were calculated and compared. Results. The MRA and DSA images of 354 ICAs could be compared. The sensitivity and specificity of MRA with the projection that showed the maximal stenosis were 92.6% (95% CI, 85.3% to 97.0%) and 82.7% (95% CI, 78.1% to 87.3%), respectively. The sensitivity and specificity with the MRA projection, corresponding with the DSA projection showing the maximal stenosis, were 88.3% (95% CI, 81.8% to 94.8%) and 89.6% (95% CI, 85.9% to 93.3%), respectively. The mean difference between maximal stenosis at MRA and DSA was 7.5% (95% CI, 5.2% to 9.9%). The mean difference between stenosis at MRA and DSA in corresponding projections was 0.4% (95% CI, -2.0% to 2.7%). Conclusion: If corresponding MRA and intraarterial DSA projections are compared, 3D TOF MRA does not overestimate carotid stenosis.
引用
收藏
页码:806 / 813
页数:8
相关论文
共 50 条
  • [41] Vertebral Artery Ostial Stenosis: Prevalence by Digital Subtraction Angiography, MR Angiography, and CT Angiography
    Dundamadappa, Sathish Kumar
    Cauley, Keith
    JOURNAL OF NEUROIMAGING, 2013, 23 (03) : 360 - 367
  • [42] Likelihood ratios in the diagnosis of renal artery stenosis by magnetic resonance angiography compared with renal angiography
    Attallah, N
    Yee, J
    Gutierrez, A
    Musial, J
    Parasuraman, R
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (12) : 987 - 992
  • [43] Accuracy of CT Angiography, MR Angiography, and Digital Subtraction Angiography in Grading of Carotid Artery Stenosis: In Comparison with Actual Measurements in an In Vitro Model
    Smith, Jason C.
    Watkins, Gregory E.
    Smith, Douglas C.
    Palmer, Eric W.
    Abou-Zamzam, Ahmed M.
    Zhang, Wayne W.
    JOURNAL OF VASCULAR SURGERY, 2011, 53 : 52S - 53S
  • [44] DIAGNOSTIC OF RENOVASCULAR HYPERTENSION DIGITAL SUBTRACTION ANGIOGRAPHY OR MAGNETIC RESONANCE ANGIOGRAPHY?
    Svejda, P.
    Soucek, M.
    JOURNAL OF HYPERTENSION, 2009, 27 : S419 - S420
  • [45] Image Quality and Stenosis Assessment of Non-Contrast-Enhanced 3-T Magnetic Resonance Angiography in Patients with Peripheral Artery Disease Compared with Contrast-Enhanced Magnetic Resonance Angiography and Digital Subtraction Angiography
    Liu, Jiayi
    Zhang, Nan
    Fang, Zhaoyang
    Luo, Nan
    Zhao, Yike
    Bi, Xiaoming
    An, Jing
    Chen, Zhong
    Liu, Dongting
    Wen, Zhaoying
    Fan, Zhanming
    Li, Debiao
    PLOS ONE, 2016, 11 (11):
  • [46] Grading of carotid artery stenosis using high resolution dynamic magnetic resonance angiography in comparison to intraarterial digital subtraction angiography. Are stenoses over 70% reliably detectable?
    Aschenbach, R
    Eger, C
    Basche, S
    Vogl, TJ
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (03): : 357 - 362
  • [47] MAGNETIC-RESONANCE ANGIOGRAPHY OF EXTRACRANIAL CAROTID AND VERTEBRAL ARTERIES, INCLUDING THEIR ORIGINS - COMPARISON WITH DIGITAL SUBTRACTION ANGIOGRAPHY
    FURUYA, Y
    ISODA, H
    HASEGAWA, S
    TAKAHASHI, M
    KANEKO, M
    UEMURA, K
    NEURORADIOLOGY, 1992, 35 (01) : 42 - 45
  • [48] EVALUATION OF THE CAROTID-ARTERY BIFURCATION - COMPARISON OF MAGNETIC-RESONANCE ANGIOGRAPHY AND DIGITAL SUBTRACTION ARCH AORTOGRAPHY
    KIDO, DK
    BARSOTTI, JB
    RICE, LZ
    ROTHENBERG, BM
    PANZER, RJ
    SOUZA, SP
    DUMOULIN, CL
    NEURORADIOLOGY, 1991, 33 (01) : 48 - 51
  • [49] CASMatching strategy for automated detection and quantification of carotid artery stenosis based on digital subtraction angiography
    Wulamu, Aziguli
    Luo, Jichang
    Chen, Saian
    Zheng, Han
    Wang, Tao
    Yang, Renjie
    Jiao, Liqun
    Zhang, Taohong
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 243
  • [50] Idiopathic Thrombus in the Common Carotid Artery on Digital Subtraction Angiography
    Alurkar, Anand
    Karanam, Lakshmi Sudha Prasanna
    Nayak, Suresh
    Oak, Sagar
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2012, 2