Overestimation of carotid artery stenosis with magnetic resonance angiography compared with digital subtraction angiography

被引:51
|
作者
Nederkoorn, PJ
Elgersma, OEH
Mali, WPTM
Eikelboom, BC
Kappelle, LJ
van der Graaf, Y
机构
[1] Univ Utrecht, Med Ctr, Julius Ctr Patient Oriented Res, NL-3508 GA Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[3] Univ Utrecht, Med Ctr, Dept Vasc Surg, NL-3508 GA Utrecht, Netherlands
[4] Univ Utrecht, Med Ctr, Dept Neurol, NL-3508 GA Utrecht, Netherlands
关键词
D O I
10.1067/mva.2002.127529
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background and purpose: Three-dimensional time-of-flight (3D TOF) magnetic resonance angiography (MRA) is generally considered to overestimate the degree of stenosis in the internal carotid artery (ICA) in comparison with the reference standard intraarterial digital subtraction angiography (DSA). We evaluated whether the degree of stenosis was more accurately assessed with 3D TOF MRA if corresponding projections on MRA and DSA were compared instead of comparison of maximal stenosis at MRA with maximal stenosis at DSA. Methods: From February 1997 to December 1999, we included 186 symptomatic and 17 asymptomatic consecutive patients suspected of having carotid artery stenosis on the basis of clinical presentation and screening with duplex ultrasound scan examination. All patients subsequently underwent DSA and MRA imaging. From each ICA, 12 maximum intensity projections with 3D TOF MRA and two or three projections with DSA were obtained. First, we compared the maximal stenosis at MRA with the maximal stenosis at DSA. Subsequently, we used the stenosis at MRA measured on the projection corresponding with the DSA projection that showed the maximal stenosis. For both strategies, the mean differences in stenosis and sensitivity and specificity for assessment of severe stenosis (70% to 99%) were calculated and compared. Results. The MRA and DSA images of 354 ICAs could be compared. The sensitivity and specificity of MRA with the projection that showed the maximal stenosis were 92.6% (95% CI, 85.3% to 97.0%) and 82.7% (95% CI, 78.1% to 87.3%), respectively. The sensitivity and specificity with the MRA projection, corresponding with the DSA projection showing the maximal stenosis, were 88.3% (95% CI, 81.8% to 94.8%) and 89.6% (95% CI, 85.9% to 93.3%), respectively. The mean difference between maximal stenosis at MRA and DSA was 7.5% (95% CI, 5.2% to 9.9%). The mean difference between stenosis at MRA and DSA in corresponding projections was 0.4% (95% CI, -2.0% to 2.7%). Conclusion: If corresponding MRA and intraarterial DSA projections are compared, 3D TOF MRA does not overestimate carotid stenosis.
引用
收藏
页码:806 / 813
页数:8
相关论文
共 50 条
  • [1] Duplex ultrasound and magnetic resonance angiography compared with digital subtraction angiography in carotid artery stenosis - A systematic review
    Nederkoorn, PJ
    van der Graaf, Y
    Hunink, M
    STROKE, 2003, 34 (05) : 1324 - 1331
  • [2] Evaluation of carotid artery stenosis: contrast-enhanced magnetic resonance angiography compared with conventional digital subtraction angiography
    Goyal, M
    Nicol, J
    Gandhi, D
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2004, 55 (02): : 111 - 119
  • [3] Internal carotid artery stenosis -: Comparison of duplex scan and magnetic resonance angiography with digital subtraction angiography
    Py, MO
    André, C
    de Azevedo, FS
    Domingues, RC
    Salomao, RF
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2001, 59 (3B) : 665 - 671
  • [4] Quantitative assessment of carotid artery stenosis: Comparison of contrast-enhanced magnetic resonance angiography and digital subtraction angiography
    Wintersperger, BJ
    Huber, AM
    Holzknecht, NG
    Helmberger, TK
    Billing, A
    Reiser, MF
    RADIOLOGY, 2001, 221 : 298 - 298
  • [5] Overestimation of the degree of stenosis in the intracranial internal carotid artery determined by magnetic resonance angiography compared to conventional arteriography
    Durán-Ferreras, E
    Schoeck, AP
    Barest, GD
    Viereck, JC
    Babikian, VL
    Kase, CS
    REVISTA DE NEUROLOGIA, 2003, 37 (08) : 730 - 732
  • [6] Detection of carotid artery stenosis using histological specimens: a comparison of CT angiography, magnetic resonance angiography, digital subtraction angiography and Doppler ultrasonography
    David Netuka
    Tomáš Belšán
    Karolina Broulíková
    Václav Mandys
    František Charvát
    Josef Malík
    Lucie Coufalová
    Ondřej Bradáč
    Svatopluk Ostrý
    Vladimír Beneš
    Acta Neurochirurgica, 2016, 158 : 1505 - 1514
  • [7] Detection of carotid artery stenosis using histological specimens: a comparison of CT angiography, magnetic resonance angiography, digital subtraction angiography and Doppler ultrasonography
    Netuka, David
    Belsan, Tomas
    Broulikova, Karolina
    Mandys, Vaclav
    Charvat, Frantisek
    Malik, Josef
    Coufalova, Lucie
    Bradac, Ondrej
    Ostry, Svatopluk
    Benes, Vladimir
    ACTA NEUROCHIRURGICA, 2016, 158 (08) : 1505 - 1514
  • [8] Comparison of intra-arterial digital subtraction angiography, magnetic resonance angiography and duplex ultrasonography for measuring carotid artery stenosis
    Modaresi, KB
    Cox, TCS
    Summers, PE
    Jarosz, JM
    Verma, H
    Taylor, PR
    Padayachee, TS
    BRITISH JOURNAL OF SURGERY, 1999, 86 (11) : 1422 - 1426
  • [9] Correlation of Computed Tomography Angiography to Digital Subtraction Angiography in Carotid Stenosis with Real-World Assessment of Overestimation of Carotid Stenosis on Computed Tomography Angiography
    Roy, Joanna M.
    Abbas, Rawad
    Chong, Weelic
    Muharemmi, Eti
    Hai, Yang
    Morse, Charles
    El Naamani, Kareem
    Atallah, Elias
    Herial, Nabeel A.
    Tjoumakaris, Stavropoula
    Gooch, Michael R.
    Rosenwasser, Robert H.
    Flanders, Adam
    Jabbour, Pascal
    WORLD NEUROSURGERY, 2024, 189
  • [10] Accuracy of Digital Subtraction Angiography, Computed Tomography Angiography, and Magnetic Resonance Angiography in Grading of Carotid Artery Stenosis in Comparison With Actual Measurement in an In Vitro Model
    Smith, Jason C.
    Watkins, Gregory E.
    Smith, Douglas C.
    Palmer, Eric W.
    Abou-Zamzam, Ahmed M.
    Zhao, Cynthia X.
    Zhang, Wayne W.
    ANNALS OF VASCULAR SURGERY, 2012, 26 (03) : 338 - 343