A practical method to calibrate the slant angle of central X-ray for laminography scanning system

被引:12
|
作者
Yang, Min [1 ]
Zhu, Jianhua [1 ]
Liu, Qiu [1 ]
Duan, Shengling [1 ]
Liang, Lihong [2 ]
Li, Xingdong [3 ]
Liu, Wenli [3 ]
Meng, Fanyong [4 ]
机构
[1] Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Beijing 100191, Peoples R China
[2] China Special Equipment Inspect & Res Inst, Beijing 100013, Peoples R China
[3] Natl Inst Metrol, Beijing 100013, Peoples R China
[4] Chinese Acad Sci, Inst Proc Engn, State Key Lab Multiphase Complex Syst, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
Computed laminography (CL); Geometrical calibration; Slant angle; Ellipse fitting; CONE-BEAM CT; RECONSTRUCTION; PARAMETERS;
D O I
10.1016/j.ndteint.2014.02.004
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Computed laminography (CL) has a particular function in plate-type structure tomography. For CL reconstruction, slant angle of the central X-ray is an important parameter and must be calibrated accurately. A practical feasible calibration method to determine the slant angle is proposed. According to this method, a spherical phantom is fixed on the rotary table and turns a full 360 rotation. Then, image processing and the least-square fitting are performed to figure out the locus of the projection. Consequently, the slant angle is achieved in accordance with the property of the fitted ellipse. The experimental results prove that this method is easy to implement and meet the inspection requirements. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [41] Three-dimensional imaging of dislocations by X-ray diffraction laminography
    Haenschke, D.
    Helfen, L.
    Altapova, V.
    Danilewsky, A.
    Baumbach, T.
    APPLIED PHYSICS LETTERS, 2012, 101 (24)
  • [42] Automated characterisation of glaciomarine sediments using X-ray computed laminography
    McDonald, Neil
    Bradwell, Tom
    Callard, S. Louise
    Toney, Jaime L.
    Shreeve, Briony
    Shreeve, James
    QUATERNARY SCIENCE ADVANCES, 2022, 5
  • [43] Recent Advances in X-ray Cone-beam Computed Laminography
    O'Brien, Neil S.
    Boardman, Richard P.
    Sinclair, Ian
    Blumensath, Thomas
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (05) : 691 - 707
  • [44] Scanning X-ray microscope
    Schelokov, IA
    Roshchupkin, DV
    Irzhak, DV
    Kondakov, AS
    CRYSTALLOGRAPHY REPORTS, 2004, 49 : S170 - S173
  • [45] THE SCANNING X-RAY MICROSCOPE
    PATTEE, HH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (01) : 61 - 62
  • [46] A SCANNING X-RAY SPECTROHELIOGRAPH
    NEGUS, CR
    GLENCROSS, WM
    POUNDS, KA
    PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1970, 317 (1528) : 101 - +
  • [47] THE SCANNING X-RAY MICROSCOPE
    PATTEE, HH
    PHYSICAL REVIEW, 1953, 92 (02): : 541 - 541
  • [49] AN X-RAY SCANNING CAMERA
    THEWLIS, J
    POLLOCK, AR
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1950, 27 (03): : 72 - 73
  • [50] X-ray Phase Laminography with a Grating Interferometer using Iterative Reconstruction
    Harasse, Sebastien
    Yashiro, Wataru
    Momose, Atsushi
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 163 - 168