Simulation of Hp(10) and effective dose received by the medical staff in interventional radiology procedures

被引:16
|
作者
Ferrari, P. [1 ]
Becker, F. [2 ]
Jovanovic, Z. [3 ]
Khan, S. [4 ]
Bakhanova, E. [5 ]
Principi, S. [6 ]
Kristic, D. [3 ]
Pierotti, L. [7 ]
Mariotti, F. [1 ]
Faj, D. [8 ]
Turk, T. [8 ,9 ]
Nikezic, D. [3 ]
Bertolini, M. [10 ]
机构
[1] ENEA IRP, Radiat Protect Inst, 4 Via Martini di Monte Sole, I-40129 Bologna, Italy
[2] Karlsruhe Inst Technol, Inst Nucl Waste Disposal, Hermann von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafen, Germany
[3] Univ Kragujevac, Fac Sci, R Domanov 12, Kragujevac 34000, Serbia
[4] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[5] Natl Res Ctr Radiat Med, Melnikova St 53, UA-04050 Kiev, Ukraine
[6] Biomed Engn Dept, 8701 W Watertown Plank Rd, Milwaukee, WI USA
[7] AOSP S Orsola Malpighi Hosp, Via Massarenti 9, I-40138 Bologna, BO, Italy
[8] Univ Osijek UNIOS, Fac Med, Josipa Huttlera 4, HR-31000 Osijek, Croatia
[9] Univ Hosp Osijek, Josipa Huttlera 4, HR-31000 Osijek, Croatia
[10] AUSL Reggio Emilia IRCCS, Viale Risorgimento 80, I-42123 Reggio Emilia, RE, Italy
关键词
interventional radiology; H-p(10); effective dose; medical staff exposure; Monte Carlo simualtions; anthropomorphic model; MONTE-CARLO CALCULATIONS; PATIENT; RADIATION; EYE; EXPOSURE; OPERATOR; HOSPITALS; EXTREMITY; DOSIMETRY; HEIGHT;
D O I
10.1088/1361-6498/ab2c42
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Interventional radiology and cardiology are widespread employed techniques for diagnosis and treatment of several pathologies because they avoid the majority of the side-effects associated with surgical treatments, but are known to increase the radiation exposure to patient and operators. In recent years many studies treated the exposure of the operators performing cardiological procedures. The aim of this work is to study the exposure condition of the medical staff in some selected interventional radiology procedures. The Monte Carlo simulations have been employed with anthropomorphic mathematical phantoms reproducing the irradiation scenario of the medical staff with two operators and the patient. A personal dosemeter, put on apron, was modelled for comparison with measurements performed in hospitals, done with electronic dosemeters, in a reduced number of interventional radiology practices. Within the limits associated to the use of numerical anthropomorphic models to mimic a complex interventional procedure, the personal dose equivalent, H-p(10), was evaluated and normalised to the simulated Kerma-Area Product, KAP, value, indeed the effective dose has been calculated. The H-p(10)/KAP(value) of the first operator is about 10 mu Sv/Gy.cm(2), when ceiling shielding is not used. This value is calculated on the trunk and it varies of +/-30% moving the dosemeter to the waist or to the neck. The effective dose, normalised to the KAP value, varies between 0.03 and 0.4 mu Sv/Gy.cm(2). Considering all the unavoidable approximation of this kind of investigations, the comparisons with hospital measurement and literature data showed a good agreement allowing to use of the present results for dosimetric characterisation of interventional radiology procedures.
引用
收藏
页码:809 / 824
页数:16
相关论文
共 50 条
  • [21] Staff radiation dose and estimated risk in an interventional radiology department
    Alkhorayef, M.
    Al-Mohammed, H. I.
    Mayhoub, Fareed H.
    Sulieman, Abdelmoneim
    Salah, Hassan
    Yousef, M.
    Alomair, Othman I.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 178
  • [22] Staff eye lens dose in interventional radiology and cardiology in Finland
    Pekkarinen, Antti
    Lindholm, Carita
    Kortesniemi, Mika
    Siiskonen, Teemu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 98 : 1 - 7
  • [23] Clarifying and Visualizing Sources of Staff-Received Scattered Radiation in Interventional Procedures
    Chida, Koichi
    Takahashi, Takeshi
    Ito, Daisuke
    Shimura, Hirotaka
    Takeda, Ken
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (05) : W900 - W903
  • [24] Management of Patient and Staff Radiation Dose in Interventional Radiology: Current Concepts
    Bartal, Gabriel
    Vano, Eliseo
    Paulo, Graciano
    Miller, Donald L.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (02) : 289 - 298
  • [25] Management of Patient and Staff Radiation Dose in Interventional Radiology: Current Concepts
    Gabriel Bartal
    Eliseo Vano
    Graciano Paulo
    Donald L. Miller
    CardioVascular and Interventional Radiology, 2014, 37 : 289 - 298
  • [26] Simulation based teaching in interventional radiology training: is it effective?
    Patel, R.
    Dennick, R.
    CLINICAL RADIOLOGY, 2017, 72 (03) : 266.e7 - 266.e14
  • [27] ESTIMATION OF STAFF LENS DOSES DURING INTERVENTIONAL PROCEDURES. COMPARING CARDIOLOGY, NEURORADIOLOGY AND INTERVENTIONAL RADIOLOGY
    Vano, E.
    Sanchez, R. M.
    Fernandez, J. M.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 279 - 283
  • [28] Organ Absorbed Doses and Effective Doses to the Patient and the Medical Staff in Interventional Radiology Calculated from Voxel Phantom
    Park, Sang-hyun
    Lee, Choonsik
    Lee, Jai-ki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 309 - 312
  • [29] Estimate Eye Lens Dose by Using Personal Dose Equivalent (HP (10)) and Dose-Area Product (DAP) in Interventional Procedures
    Hu, P.
    Wang, J.
    Hu, W.
    Liu, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E276 - E276
  • [30] Eye Lens Doses Received by Radiation Workers in Interventional Medical Procedures
    Hiswara, E.
    Kartikasari, D.
    Sofyan, H.
    Nuraeni, N.
    Sandy, Kyp
    ATOM INDONESIA, 2020, 46 (03) : 135 - 140