Effect of implementing safety-engineered devices on percutaneous injury epidemiology

被引:56
|
作者
Sohn, S [1 ]
Eagan, J [1 ]
Sepkowitz, KA [1 ]
Zuccotti, G [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Infect Dis Serv, Dept Med, New York, NY 10021 USA
来源
关键词
D O I
10.1086/502436
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE: To assess the effect of implementing safety-engineered devices on percutaneous injury epidemiology, specifically on percutaneous injuries associated with a higher risk of blood-borne pathogen exposure. DESIGN: Before-and-after intervention trial comparing 3-year preintervention (1998-2000) and 1-year postintervention (2001-2002) periods. Percutaneous injury data have been entered prospectively into CDC NaSH software since 1998. SETTING: A 427-bed, tertiary-care hospital in Manhattan. PARTICIPANTS: All employees who reported percutaneous injuries during the study period. INTERVENTION: A "safer-needle system," composed of a variety of safety-engineered devices to allow for needle-safe IV delivery, blood collection, IV insertion, and intramuscular and subcutaneous injection, was implemented in February 2001. RESULTS: The mean annual incidence of percutaneous injuries decreased from 34.08 per 1,000 full-time-equivalent employees preintervention to 14.25 postintervention (P < .001). Reductions in the average monthly number of percutaneous injuries resulting from both low-risk (P < .01) and high-risk (P was not significant) activities were observed. Nurses experienced the greatest decrease (74.5%, P < .001), followed by ancillary staff (61.5%, P =.03). Significant rate reductions were observed for the following activities: manipulating patients or sharps (83.5%, P < .001), collisions or contact with sharps (73.0%, P = .01), disposal-related injuries (21.41%, P = .001), and catheter insertions (88.2%, P < .001). Injury rates involving hollow-bore needles also decreased (70.6%, P < .001). CONCLUSIONS: The implementation of safety-engineered devices reduced percutaneous injury rates across occupations, activities, times of injury, and devices. Moreover, intervention impact was observed when stratified by risk for blood-borne pathogen transmission.
引用
收藏
页码:536 / 542
页数:7
相关论文
共 50 条
  • [41] UK safety-engineered device use: changes since the 2013 sharps regulations (vol 69, pg 352, 2019)
    Grimmond, T.
    OCCUPATIONAL MEDICINE-OXFORD, 2019, 69 (8-9): : 641 - 641
  • [42] Safety-Engineered Syringes: An Intervention to Decrease Hepatitis C Burden in Developing Countries-A Cost-Effectiveness Analysis From Egypt
    Mostafa, Aya
    El-Sayed, Manal H.
    El Kassas, Mohamed
    Elhamamsy, Manal
    Elsisi, Gihan Hamdy
    VALUE IN HEALTH REGIONAL ISSUES, 2019, 19 : 51 - 58
  • [43] Effect of microtextured surfaces on the performance of percutaneous devices
    Walboomers, XF
    Jansen, JA
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2005, 74A (03) : 381 - 387
  • [44] Hazard Based Safety Engineering in Relation to Injury Epidemiology and Etiology
    Lanzisero, Thomas
    2014 IEEE SYMPOSIUM ON PRODUCT COMPLIANCE ENGINEERING (ISPCE 2014), 2014, : 41 - 49
  • [45] Use of safety devices and the prevention of percutaneous injuries among healthcare workers
    Valls, Victoria
    Lozano, Salud
    Yanez, Remedios
    Martinez, Maria Jose
    Pascual, Francisco
    Lloret, Joan
    Ruiz, Juan Antonio
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2007, 28 (12): : 1352 - 1360
  • [46] The comparison of heparinized insulin syringes and safety-engineered blood gas syringes used in arterial blood gas sampling in the ED setting (randomized controlled study)
    Baskin, Sevcan Baki
    Oray, Nese Colak
    Yanturali, Sedat
    Bayram, Basak
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (05): : 432 - 437
  • [47] DID SAFETY-ENGINEERED DEVICE IMPLEMENTATION CONTRIBUTETO REDUCING THE RISK OF NEEDLESTICK AND SHARPS INJURIES? RETROSPECTIVE INVESTIGATION OF 20 YEARS OF OBSERVATION IN A SPECIALISTTERTIARY REFERRAL HOSPITAL
    Szczypta, Anna
    Rozanska, Anna
    Siewierska, Malgorzata
    Drozdz, Kamil
    Szura, Miroslaw
    Talaga-Cwiertnia, Katarzyna
    INTERNATIONAL JOURNAL OF OCCUPATIONAL MEDICINE AND ENVIRONMENTAL HEALTH, 2024, 37 (02) : 234 - 243
  • [48] Effect of Percutaneous Ventricular Assist Devices on Renal Function
    Mao, Huijuan
    Giuliani, Anna
    Blanca-Martos, Lourdes
    Kim, Jeong Chul
    Nayak, Akash
    Virzi, Grazia
    Brocca, Alessandra
    Scalzotto, Elisa
    Neri, Mauro
    Katz, Nevin
    Ronco, Claudio
    BLOOD PURIFICATION, 2013, 35 (1-3) : 119 - 126
  • [49] Percutaneous left atrial appendage closure devices: safety, efficacy, and clinical utility
    Swaans, Martin J.
    Wintgens, Lisette I. S.
    Alipour, Arash
    Rensing, Benno J. W. M.
    Boersma, Lucas V. A.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2016, 9 : 309 - 316