Effect of implementing safety-engineered devices on percutaneous injury epidemiology

被引:56
|
作者
Sohn, S [1 ]
Eagan, J [1 ]
Sepkowitz, KA [1 ]
Zuccotti, G [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Infect Dis Serv, Dept Med, New York, NY 10021 USA
来源
关键词
D O I
10.1086/502436
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE: To assess the effect of implementing safety-engineered devices on percutaneous injury epidemiology, specifically on percutaneous injuries associated with a higher risk of blood-borne pathogen exposure. DESIGN: Before-and-after intervention trial comparing 3-year preintervention (1998-2000) and 1-year postintervention (2001-2002) periods. Percutaneous injury data have been entered prospectively into CDC NaSH software since 1998. SETTING: A 427-bed, tertiary-care hospital in Manhattan. PARTICIPANTS: All employees who reported percutaneous injuries during the study period. INTERVENTION: A "safer-needle system," composed of a variety of safety-engineered devices to allow for needle-safe IV delivery, blood collection, IV insertion, and intramuscular and subcutaneous injection, was implemented in February 2001. RESULTS: The mean annual incidence of percutaneous injuries decreased from 34.08 per 1,000 full-time-equivalent employees preintervention to 14.25 postintervention (P < .001). Reductions in the average monthly number of percutaneous injuries resulting from both low-risk (P < .01) and high-risk (P was not significant) activities were observed. Nurses experienced the greatest decrease (74.5%, P < .001), followed by ancillary staff (61.5%, P =.03). Significant rate reductions were observed for the following activities: manipulating patients or sharps (83.5%, P < .001), collisions or contact with sharps (73.0%, P = .01), disposal-related injuries (21.41%, P = .001), and catheter insertions (88.2%, P < .001). Injury rates involving hollow-bore needles also decreased (70.6%, P < .001). CONCLUSIONS: The implementation of safety-engineered devices reduced percutaneous injury rates across occupations, activities, times of injury, and devices. Moreover, intervention impact was observed when stratified by risk for blood-borne pathogen transmission.
引用
收藏
页码:536 / 542
页数:7
相关论文
共 50 条
  • [21] Image-Directed Fine-needle Aspiration Biopsy of the Thyroid with Safety-engineered Devices
    Randy R. Sibbitt
    Dennis J. Palmer
    Wilmer L. Sibbitt
    Arthur D. Bankhurst
    CardioVascular and Interventional Radiology, 2011, 34 : 1006 - 1013
  • [22] Image-Directed Fine-needle Aspiration Biopsy of the Thyroid with Safety-engineered Devices
    Sibbitt, Randy R.
    Palmer, Dennis J.
    Sibbitt, Wilmer L., Jr.
    Bankhurst, Arthur D.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (05) : 1006 - 1013
  • [23] Provision and use of safety-engineered medical devices among home care and hospice nurses in North Carolina
    Leiss, Jack K.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2010, 38 (08) : 636 - 639
  • [24] Reducing needlestick injuries through safety-engineered devices: results of a Japanese multi-centre study
    Fukuda, H.
    Yamanaka, N.
    JOURNAL OF HOSPITAL INFECTION, 2016, 92 (02) : 147 - 153
  • [25] A BUDGET IMPACT MODEL TO INVESTIGATE POTENTIAL COST SAVINGS ASSOCIATED WITH THE USE OF SAFETY-ENGINEERED SHARP DEVICES IN BELGIUM
    Hanmore, E.
    Ruff, L.
    Maclaine, G. D. H.
    Garin, F.
    Leroy, N.
    VALUE IN HEALTH, 2012, 15 (07) : A346 - A347
  • [26] Economic evaluation of safety-engineered devices and training in reducing needlestick injuries among healthcare workers in South Africa
    de Jager, P.
    Zungu, M.
    Dyers, R. E.
    SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2018, 108 (06): : 477 - 483
  • [27] SHOULD THE GOVERNMENT INTERVENE IN THE IMPLEMENTATION ON SAFETY-ENGINEERED DEVICES? EVIDENCE FROM A COST-EFFECTIVENESS ANALYSIS OF NEEDLESTICK INJURIES
    Fukuda, H.
    Moriwaki, K.
    VALUE IN HEALTH, 2016, 19 (03) : A304 - A304
  • [28] Safety-engineered intravenous catheter utilization among Canadian pediatric anesthesiologists
    Murto, Kimmo
    Breton, Sophie
    Ramakko, Kelly-Ann
    Aglipay, Mary
    Perverseff, Rob
    Bryson, Gregory L.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (05): : 461 - 475
  • [29] Use of safety-engineered devices by healthcare workers for intravenous and/or phlebotomy procedures in healthcare settings: a systematic review and meta-analysis
    Rami A. Ballout
    Batoul Diab
    Alain C. Harb
    Rami Tarabay
    Selma Khamassi
    Elie A. Akl
    BMC Health Services Research, 16
  • [30] Use of safety-engineered devices by healthcare workers for intravenous and/or phlebotomy procedures in healthcare settings: a systematic review and meta-analysis
    Ballout, Rami A.
    Diab, Batoul
    Harb, Alain C.
    Tarabay, Rami
    Khamassi, Selma
    Akl, Elie A.
    BMC HEALTH SERVICES RESEARCH, 2016, 16