Purification of biodiesel using a membrane contactor: Liquid-liquid extraction

被引:25
|
作者
Amelio, A. [1 ]
Loise, L. [2 ]
Azhandeh, R. [1 ]
Darvishmanesh, S. [1 ]
Calabro, V. [2 ]
Degreve, J. [4 ]
Luis, P. [3 ]
Van der Bruggen, B. [1 ,5 ]
机构
[1] Katholieke Univ Leuven, Proc Engn Sustainable Syst ProcESS, Dept Chem Engn, B-3001 Leuven, Belgium
[2] Univ Calabria, Dept Modeling Engn, I-87036 Arcavacata Di Rende, Italy
[3] Catholic Univ Louvain, Mat & Proc Engn iMMC IMAP, B-1348 Louvain La Neuve, Belgium
[4] Katholieke Univ Leuven, Chem & Biochem Proc Technol & Control Sect BioTec, Dept Chem Engn, B-3001 Leuven, Belgium
[5] Tshwane Univ Technol, Fac Engn & Built Environm, ZA-0001 Pretoria, South Africa
关键词
Membrane extraction; Biodiesel purification; Hydrophobic; Flat sheet membranes; SOLVENT-EXTRACTION; MASS-TRANSFER; REMOVAL; AMMONIA; ENERGY;
D O I
10.1016/j.fuproc.2015.10.037
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The use of biodiesel in engines requires a high purity (99.65 wt.%), which is to be obtained by the removal of a large water amount and a large number of distillation steps. Membrane extraction was studied as a more efficient and environmentally friendly process to purify a synthetic biodiesel stream composed of methyl esters from rapeseed oil, methanol and glycerol. The potential of several flat sheet membranes to remove impurities was evaluated. All hydrophobic membranes showed breakthrough pressure values higher than 0.5 bar. A PTFE membrane from Sterlitech was selected due to its high chemical resistance against biodiesel. The effect of the concentration of solutes and of the flow rate on the flux was investigated. The overall mass transfer coefficient was calculated and compared with experimentally observed values, which are in the range of 3.5-7 E-03 (cm/min) for methanol. Thus, this membrane technique allows purifying biodiesel, suggesting its potential in industrial applications. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:352 / 360
页数:9
相关论文
共 50 条
  • [41] Scalable Enantioseparation of Amino Acid Derivatives Using Continuous Liquid-Liquid Extraction in a Cascade of Centrifugal Contactor Separators
    Schuur, Boelo
    Hallet, Andrew J.
    Winkelman, Jozef G. M.
    de Vries, Johannes G.
    Heeres, Hero J.
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2009, 13 (05) : 911 - 914
  • [42] Numerical simulation of mass transfer in a liquid-liquid membrane contactor for laminar flow conditions
    Kieffer, Roland
    Charcosset, Catherine
    Puel, Francois
    Mangin, Denis
    COMPUTERS & CHEMICAL ENGINEERING, 2008, 32 (06) : 1325 - 1333
  • [43] Heat and Mass Transfer in a Quasi-Counter Flow Liquid-Liquid Membrane Contactor
    Huang, Wei-Hao
    Yang, Min-Lin
    Huang, Si-Min
    Qin, Guan-Feng
    Zuo, Yuan-Zhi
    Shao, You-Yuan
    Zhao, Hong-Bin
    Xu, Yong-Jun
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2018, 39 (02): : 423 - 427
  • [44] Process intensification of catalytic liquid-liquid solid processes: Continuous biodiesel production using an immobilized lipase in a centrifugal contactor separator
    Ilmi, M.
    Kloekhorst, A.
    Winkelman, J. G. M.
    Euverink, G. J. W.
    Hidayat, C.
    Heeres, H. J.
    CHEMICAL ENGINEERING JOURNAL, 2017, 321 : 76 - 85
  • [45] Liquid-liquid extraction
    Jenkins, Scott
    Chemical Engineering (United States), 2015, 122 (06):
  • [46] LIQUID-LIQUID EXTRACTION
    VASHIST, PN
    BECKMAN.RB
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1968, 60 (11): : 43 - &
  • [47] LIQUID-LIQUID EXTRACTION
    JOSEPHNA.P
    JOURNAL OF CHEMICAL EDUCATION, 1967, 44 (03) : 176 - &
  • [48] LIQUID-LIQUID EXTRACTION
    ELLIS, WB
    BECKMANN, RB
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1965, 57 (11): : 103 - &
  • [49] Liquid-liquid extraction
    Bergelin, O
    Lockhart, FJ
    Brown, GG
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF CHEMICAL ENGINEERS, 1943, 39 : 0173 - 0200
  • [50] Liquid-liquid extraction
    Neue, Uwe Dieter