Purification of biodiesel using a membrane contactor: Liquid-liquid extraction

被引:25
|
作者
Amelio, A. [1 ]
Loise, L. [2 ]
Azhandeh, R. [1 ]
Darvishmanesh, S. [1 ]
Calabro, V. [2 ]
Degreve, J. [4 ]
Luis, P. [3 ]
Van der Bruggen, B. [1 ,5 ]
机构
[1] Katholieke Univ Leuven, Proc Engn Sustainable Syst ProcESS, Dept Chem Engn, B-3001 Leuven, Belgium
[2] Univ Calabria, Dept Modeling Engn, I-87036 Arcavacata Di Rende, Italy
[3] Catholic Univ Louvain, Mat & Proc Engn iMMC IMAP, B-1348 Louvain La Neuve, Belgium
[4] Katholieke Univ Leuven, Chem & Biochem Proc Technol & Control Sect BioTec, Dept Chem Engn, B-3001 Leuven, Belgium
[5] Tshwane Univ Technol, Fac Engn & Built Environm, ZA-0001 Pretoria, South Africa
关键词
Membrane extraction; Biodiesel purification; Hydrophobic; Flat sheet membranes; SOLVENT-EXTRACTION; MASS-TRANSFER; REMOVAL; AMMONIA; ENERGY;
D O I
10.1016/j.fuproc.2015.10.037
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The use of biodiesel in engines requires a high purity (99.65 wt.%), which is to be obtained by the removal of a large water amount and a large number of distillation steps. Membrane extraction was studied as a more efficient and environmentally friendly process to purify a synthetic biodiesel stream composed of methyl esters from rapeseed oil, methanol and glycerol. The potential of several flat sheet membranes to remove impurities was evaluated. All hydrophobic membranes showed breakthrough pressure values higher than 0.5 bar. A PTFE membrane from Sterlitech was selected due to its high chemical resistance against biodiesel. The effect of the concentration of solutes and of the flow rate on the flux was investigated. The overall mass transfer coefficient was calculated and compared with experimentally observed values, which are in the range of 3.5-7 E-03 (cm/min) for methanol. Thus, this membrane technique allows purifying biodiesel, suggesting its potential in industrial applications. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:352 / 360
页数:9
相关论文
共 50 条
  • [31] On-line automated sample preparation for liquid chromatography using parallel supported liquid membrane extraction and microporous membrane liquid-liquid extraction
    Sandah, M
    Mathiasson, L
    Jönsson, JÅ
    JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) : 211 - 217
  • [32] Application of hollow fiber membrane contactor for the removal of carbon dioxide from water under liquid-liquid extraction mode
    Agrahari, Gunjan K.
    Verma, Nishith
    Bhattacharya, Prashant K.
    JOURNAL OF MEMBRANE SCIENCE, 2011, 375 (1-2) : 323 - 333
  • [33] Factors affecting microporous membrane liquid-liquid extraction
    Kuosmanen, K
    Lehmusjärvi, M
    Hyötyläinen, T
    Jussila, M
    Riekkola, ML
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10): : 893 - 902
  • [34] A LIQUID-LIQUID CONTACTOR FOR EXTRACORPOREAL BLOOD OXYGENATION
    ANDERSON, RM
    HARRIS, GW
    DEFILIPPI, RP
    WEBER, DC
    MALCHESKY, PS
    NOSE, Y
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1970, 16 : 375 - +
  • [35] Extraction of Co and Ni Metals Using Emulsion Liquid Membrane and Liquid-Liquid Extraction with Cyanex 272 as Extractant
    Yuliusman
    Silvia
    Nurqomariah, Annisaa
    Fajaryanto, Radifan
    11TH REGIONAL CONFERENCE ON CHEMICAL ENGINEERING (RCCHE 2018), 2019, 2085
  • [36] Investigation of ferulic acid recovery from enzymatic hydrolysate of wheat bran using various solvents and liquid-liquid extraction assisted by membrane contactor
    Chadni, Morad
    Haudrechy, Arnaud
    Couvreur, Julien
    Allais, Florent
    JOURNAL OF MOLECULAR LIQUIDS, 2024, 400
  • [37] Liquid-liquid extraction and transport across supported liquid membrane of phenol using tributyl phosphate
    Zidi, Chiraz
    Tayeb, Rafik
    Ali, Mourad Ben Sik
    Dhahbi, Mahmoud
    JOURNAL OF MEMBRANE SCIENCE, 2010, 360 (1-2) : 334 - 340
  • [38] Purification of natural amorphous graphite using an oscillating liquid-liquid continuous extraction apparatus
    Hayashi, T
    Saitou, K
    Tamura, J
    Otsuka, N
    Tonooka, Y
    JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 2000, 108 (06) : 598 - 603
  • [39] Multicomponent and contamination effects on mass transfer in a liquid-liquid extraction rotating disc contactor
    Brodkorb, MJ
    Slater, MJ
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2001, 79 (A3): : 335 - 346
  • [40] Optimization study on continuous separation of equol enantiomers using enantioselective liquid-liquid extraction in centrifugal contactor separators
    Tang, Kewen
    Wang, Yaqiong
    Zhang, Panliang
    Huang, Yan
    Hua, Jie
    PROCESS BIOCHEMISTRY, 2016, 51 (01) : 113 - 123