Application of contact-resonance AFM methods to polymer samples

被引:2
|
作者
Friedrich, Sebastian [1 ]
Cappella, Brunero [1 ]
机构
[1] BAM Fed Inst Mat Res & Testing, Unter Eichen 87, D-12205 Berlin, Germany
基金
欧盟地平线“2020”;
关键词
atomic force microscopy; contact resonance; mechanical properties; polymers; wear; ATOMIC-FORCE MICROSCOPE; ACOUSTIC MICROSCOPY; ELASTIC PROPERTIES; DISTANCE CURVES; SURFACE; RECONSTRUCTION; CANTILEVERS; DEFORMATION; POLYSTYRENE; TRANSITION;
D O I
10.3762/bjnano.11.154
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Contact-resonance AFM (CR-AFM) has been used in recent years for the measurement of mechanical properties of rather stiff materials, such as ceramics or metals, but also of some polymers. Compared with other techniques providing information on the mechanical properties of a sample, notably force-distance curves, CR-AFM has a much shorter acquisition time. This compensates in part the incomplete theoretical understanding of the underlying physical phenomena and of factors influencing the measurements. A commonly used method to analyze CR data requires the determination of the relative position of the tip, the calculation of the normalized contact stiffness, and the use of a calibration sample for the calculation of the elastic modulus of the sample. In the present paper, we propose an alternative procedure, based on approximations of the equations describing the system, which allows one to determine the elastic modulus of the sample as a parameter of the fit of the CR frequency as a function of the load. After showing that CR modes including scanning under continuous contact wear and damage the sample and/or alter the surface roughness, the results of point CR measurements on bulk and thin films are presented. Though Young's moduli of bulk polystyrene and poly(methyl methacrylate) could be determined through the presented analysis, it is concluded that CR measurements are not appropriate for polymer samples. Major drawbacks are the bad resolution for moduli lower than ca. 10 GPa and the lack of a comprehensive physical model accounting for many factors affecting the dynamic response of a cantilever in contact with a sample.
引用
收藏
页码:1714 / 1727
页数:14
相关论文
共 50 条
  • [21] Local probe of the interlayer coupling strength of few-layers SnSe by contact-resonance atomic force microscopy
    Zheng, Zhi-Yue
    Pan, Yu-Hao
    Pei, Teng-Fei
    Xu, Rui
    Xu, Kun-Qi
    Lei, Le
    Hussain, Sabir
    Liu, Xiao-Jun
    Bao, Li-Hong
    Gao, Hong-Jun
    Ji, Wei
    Cheng, Zhi-Hai
    FRONTIERS OF PHYSICS, 2020, 15 (06)
  • [22] Experimental validation of contact resonance AFM using long massive tips
    Zimron-Politi, Nadav
    Tung, Ryan C.
    NANOTECHNOLOGY, 2023, 34 (36)
  • [24] Measuring interdiffusion at an interface between two elastomers with tapping-mode and contact-resonance atomic force microscopy Imaging
    Bresson, Bruno
    Portigliatti, Maude
    Salvant, Benoit
    Fretigny, Christian
    JOURNAL OF APPLIED POLYMER SCIENCE, 2008, 109 (01) : 602 - 607
  • [25] Characterization of AFM for elasticity analysis of biological samples: application to diagnosis
    Demichelis, A.
    Divieto, C.
    Mortati, L.
    Pavarelli, S.
    Sassi, M.
    Sassi, G.
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 283 - 288
  • [26] Local probe of the interlayer coupling strength of few-layers SnSe by contact-resonance atomic force microscopy
    Zhi-Yue Zheng
    Yu-Hao Pan
    Teng-Fei Pei
    Rui Xu
    Kun-Qi Xu
    Le Lei
    Sabir Hussain
    Xiao-Jun Liu
    Li-Hong Bao
    Hong-Jun Gao
    Wei Ji
    Zhi-Hai Cheng
    Frontiers of Physics, 2020, 15
  • [27] Surface AFM Microscopy of Unworn and Worn Samples of Silicone Hydrogel Contact Lenses
    Gonzalez-Meijome, J. M.
    Lopez-Alemany, A.
    Almeida, J. B.
    Parafita, M. A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (01) : 75 - 82
  • [28] Measuring interdiffusion at an interface between two elastomers with tapping-mode and contact-resonance atomic force microscopy imaging
    Bresson, Bruno
    Portigliatti, Maude
    Salvant, Benoit
    Fretigny, Christian
    Journal of Applied Polymer Science, 2008, 109 (01): : 602 - 607
  • [29] HYBRID COMPUTATIONAL METHODS FOR ANALYSIS OF AFM INDENTATION ON MECHANICALLY HETEROGENEOUS SAMPLES
    Azeloglu, Evren U.
    Kaushik, Gaurav
    Costa, Kevin D.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 557 - 558
  • [30] Estimation of polymer-surface interfacial interaction strength by a contact AFM technique
    Dvir, H.
    Jopp, J.
    Gottlieb, M.
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2006, 304 (01) : 58 - 66