A comparison of accuracy of 3 intraoral scanners: A single-blinded in vitro study

被引:63
|
作者
Michelinakis, George [1 ]
Apostolakis, Dimitrios [2 ]
Tsagarakis, Andreas
Kourakis, George [2 ]
Pavlakis, Emmanuil [3 ]
机构
[1] Crete Implants Private Dent Practice, 5 Riga Feraiou Sqr, Iraklion 71201, Crete, Greece
[2] Dent Radiol Crete, Iraklion, Greece
[3] Prosthetiki Dent Lab, Iraklion, Greece
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2020年 / 124卷 / 05期
关键词
FULL-ARCH IMPRESSIONS; DENTAL IMPRESSIONS; DIGITAL METHODS; REPRODUCIBILITY; PRECISION; VIVO;
D O I
10.1016/j.prosdent.2019.10.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Measuring both the trueness and precision of an intraoral scanner (IOS) will provide a thorough understanding of its accuracy. Purpose. The purpose of this in vitro study was to measure the complete-arch trueness and precision of 3 commercially available intraoral scanners equipped with the latest software version and compare them by using a laboratory scanner as reference. Material and methods. Nineteen maxillary and 19 mandibular completely dentate stone casts previously acquired from 19 patients by using a polyvinyl siloxane (PVS) dual mix impression and stock trays were scanned with 3 intraoral scanners (TRIOS 3; 3Shape A/S, i500; Medit, and Emerald; Planmeca) using their latest software versions. The same casts were also scanned with a laboratory scanner (E3; 3Shape A/S) that served as the reference scanner. Files were exported in standard tessellation language (STL) format and inserted into a metrology 3D mesh comparison software program (CloudCompare). Results. In terms of trueness, a significant difference was found among the scanners (F (2.37)=239.7, P<.001). Planmeca Emerald had significantly lower trueness values than either the Medit i500 ( P<.001) or the 3Shape A/S TRIOS 3 ( P<.001). No significant difference in trueness was found between the Medit i500 and the 3Shape A/S TRIOS 3 scanner ( P=.365). In terms of precision, a significant difference was found among the scanners (F (2.89)=301.2, P<.001). The 3Shape A/S TRIOS 3 scanner was significantly more precise than the other scanners ( P<.001 for both the Medit i500 and Planmeca Emerald). The Planmeca scanner was significantly more precise than the Medit i500 scanner ( P<.001). Concerning the ability of the scanners to reproduce the files of the reference scanner without overestimation or underestimation, the Medit i500 produced files that significantly underestimated the reference scanner's files (t (37)=-12.4, P<.001). The other scanners did not significantly either underestimate or overestimate the files of the standard (t (37)=-1.91, P=.062 for the TRIOS 3 and t (37)=1.64, P=.101 for the Planmeca) Conclusions. With regard to completely dentate arch trueness, the Planmeca Emerald IOS had statistically lower trueness. With regard to complete dentate arch precision, the 3Shape A/S TRIOS 3 IOS was the statistically more precise scanner. With regard to reference scanner file estimation, the Medit i500 IOS produced files that significantly underestimated the reference scanner files. All 3 tested scanners exhibited a completely dentate arch average accuracy below 100 mu m in vitro.
引用
收藏
页码:581 / 588
页数:8
相关论文
共 50 条
  • [1] Influence of Different Material Substrates on the Accuracy of Three Intraoral Scanners: A Single-Blinded In Vitro Study
    Michelinakis, George
    Apostolakis, Dimitrios
    Tsagarakis, Andreas
    Lampropoulos, Panagiotis
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (01) : 82 - 93
  • [2] A comparison of the accuracy of intraoral scanners using an intraoral environment simulator
    Park, Hye-Nan
    Lim, Young-Jun
    Yi, Won-Jin
    Han, Jung-Suk
    Lee, Seung-Pyo
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (01): : 58 - 64
  • [3] Comparison of Accuracy of Current Ten Intraoral Scanners
    Amornvit, Pokpong
    Rokaya, Dinesh
    Sanohkan, Sasiwimol
    [J]. BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [4] In vitro Evaluation of Accuracy of Single Dies Captured by Two Intraoral Digital Scanners
    Burde, Alexandru Victor
    Gasparik, Cristina
    Moldovan, Marioara
    Baciu, Sorana
    Cosma, Cosmin
    [J]. MATERIALE PLASTICE, 2018, 55 (02) : 176 - 178
  • [5] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    [J]. HEALTHCARE, 2021, 9 (03):
  • [6] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Imburgia, Mario
    Logozzo, Silvia
    Hauschild, Uli
    Veronesi, Giovanni
    Mangano, Carlo
    Mangano, Francesco Guido
    [J]. BMC ORAL HEALTH, 2017, 17
  • [7] Influence of Liquid on the Tooth Surface on the Accuracy of Intraoral Scanners: An In Vitro Study
    Chen, Yuming
    Zhai, Zhihao
    Li, Hefei
    Yamada, Shuhei
    Matsuoka, Takashi
    Ono, Shinji
    Nakano, Tamaki
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (01): : 59 - 64
  • [8] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Mario Imburgia
    Silvia Logozzo
    Uli Hauschild
    Giovanni Veronesi
    Carlo Mangano
    Francesco Guido Mangano
    [J]. BMC Oral Health, 17
  • [9] A comparison of accuracy between three different facial detection systems for prosthodontic esthetic preview: a single-blinded in vitro study
    Ortensi, Luca
    Fisichella, Maria L.
    Ortensi, Marco
    Grande, Francesco
    Pellegrino, Gerardo
    Ferri, Agnese
    La Rosa, Giusy R. M.
    Pedulla, Eugenio
    [J]. MINERVA DENTAL AND ORAL SCIENCE, 2022, 71 (04) : 199 - 205
  • [10] Accuracy of Five Intraoral Scanners and Two Laboratory Scanners for a Complete Arch: A Comparative In Vitro Study
    Kang, Byung-hyun
    Son, Keunbada
    Lee, Kyu-bok