Comparison of Accuracy of Current Ten Intraoral Scanners

被引:58
|
作者
Amornvit, Pokpong [1 ]
Rokaya, Dinesh [2 ]
Sanohkan, Sasiwimol [1 ]
机构
[1] Prince Songkla Univ, Fac Dent, Dept Prosthet Dent, Hat Yai 90110, Songkhla, Thailand
[2] Walailak Univ, Int Coll Dent, Dept Clin Dent, Bangkok 10400, Thailand
关键词
D O I
10.1155/2021/2673040
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
There have been various developments in intraoral 3D scanning technology. This study is aimed at investigating the accuracy of 10 scanners developed from 2015 to 2020. A maxillary dental model with reference points was printed from Form 2 (FormLabs, Somerville, MA, USA). The model was scanned 5 times with each intraoral scanner (IOS); Trios 3 (normal and high-resolution mode); Trios 4 (normal and high-resolution mode) (3Shape Trios A/S, Copenhagen, Denmark); iTero Element, iTero 2, and iTero 5D Element (Align Technologies, San Jose, California, USA); Dental Wings (Dental Wings, Montreal QC, Canada); Panda 2 (Pengtum Technologies, Shanghai, China); Medit i500 (Medit Corp. Seoul, South Korea); Planmeca Emerald (TM) (Planmeca, Helsinki, Finland); and Aoralscan (Shining 3D Tech. Co., Ltd., Hangzhou, China). After the scan, the 3D scanned stereolithography files were created. The various distances were measured five times in X, Y, Z, and XY axes of various scans and with a vernier caliper (control) and from the Rhinoceros software. The data were analyzed using SPSS 18. Test for the normality of the various measurement data were done using Kolmogorov-Smirnov test. The trueness and precision of the measurements were compared among the various scans using the Kruskal-Wallis test. The significance was considered at P < 0.05. The trueness of the intraoral scans was analyzed by comparing the measurements from the control. Precision was tested through the measurements of repeated scans. It showed that more the distance is less the accuracy for all scanners. In all studied scanners, the trueness varied but precision was favorably similar. Diagonal scanning showed less accuracy for all the scanners. Hence, when scanning the full arch, the dentist needs to take more caution and good scan pattern. Trios series showed the best scan results compared to other scanners.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A comparison of the accuracy of intraoral scanners using an intraoral environment simulator
    Park, Hye-Nan
    Lim, Young-Jun
    Yi, Won-Jin
    Han, Jung-Suk
    Lee, Seung-Pyo
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (01): : 58 - 64
  • [2] Accuracy of commercial intraoral scanners
    Sacher, Mattia
    Schulz, Georg
    Deyhle, Hans
    Jaeger, Kurt
    Mueller, Bert
    [J]. JOURNAL OF MEDICAL IMAGING, 2021, 8 (03)
  • [3] Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation
    Porter, Jason L.
    Carrico, Caroline K.
    Lindauer, Steven J.
    Tufekci, Eser
    [J]. JOURNAL OF ORTHODONTICS, 2018, 45 (04) : 275 - 282
  • [4] Accuracy, Time, and Comfort of Different Intraoral Scanners: An In Vivo Comparison Study
    Lione, Roberta
    De Razza, Francesca Chiara
    Gazzani, Francesca
    Lugli, Letizia
    Cozza, Paola
    Pavoni, Chiara
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [5] Evaluation and comparison of the accuracy of three intraoral scanners for replicating a complete denture
    Le Texier, Louise
    Nicolas, Emmanuel
    Batisse, Cindy
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04):
  • [6] Comparison of the Accuracy of Intraoral Scanners Based on the Type of Tooth Preparation for a Single Crown
    Lee, Dong-Geun
    Son, Keunbada
    Lee, Kyu-Bok
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (20):
  • [7] A comparison of accuracy of 3 intraoral scanners: A single-blinded in vitro study
    Michelinakis, George
    Apostolakis, Dimitrios
    Tsagarakis, Andreas
    Kourakis, George
    Pavlakis, Emmanuil
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (05): : 581 - 588
  • [8] The impact of software updates on accuracy of intraoral scanners
    Schmalzl, Judit
    Roth, Ivett
    Borbely, Judit
    Hermann, Peter
    Vecsei, Balint
    [J]. BMC ORAL HEALTH, 2023, 23 (01)
  • [9] Accuracy and Reliability of Intraoral Scanners: Are They the Better Option?
    Ebeid K.
    Salah T.
    Nossair S.
    [J]. Current Oral Health Reports, 2017, 4 (3) : 209 - 214
  • [10] The impact of software updates on accuracy of intraoral scanners
    Judit Schmalzl
    Ivett Róth
    Judit Borbély
    Péter Hermann
    Bálint Vecsei
    [J]. BMC Oral Health, 23