Pupil perimetry in the diagnosis of functional visual field loss

被引:14
|
作者
Rajan, MS
Bremner, FD
Riordan-Eva, P
机构
[1] Kings Coll Hosp London, London, England
[2] Natl Hosp Neurol & Neurosurg, London WC1N 3BG, England
关键词
D O I
10.1258/jrsm.95.10.498
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The diagnosis of functional visual loss-reduced visual performance in the absence of an organic cause-is usually made by exclusion. We conducted a pilot study to evaluate pupil perimetry in three patients (aged 14,43 and 50) with visual field loss presumed to be functional on clinical grounds and having no cause identified by visual electrophysiology or magnetic resonance imaging. A modified automated perimeter was used to examine visual and pupil responses to a light stimulus (size 1.7) presented at five locations in the visual field (fixation and in each of the four quadrants). In each patient, the pupil responses were normal in those test quadrants which showed apparent visual field loss. Pupil perimetry provides objective evidence for a diagnosis of functional visual field loss in selected patients and may circumvent the need for other investigations.
引用
收藏
页码:498 / 500
页数:3
相关论文
共 50 条
  • [21] Comparison of pupil perimetry and visual perimetry in normal eyes: Decibel sensitivity and variability
    Hong, S
    Narkiewicz, J
    Kardon, RH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (05) : 957 - 965
  • [22] Computerized kinetic perimetry detects tubular visual fields in patients with functional visual loss
    Pineles, SL
    Volpe, NJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (05) : 933 - 935
  • [23] Threshold Automated Perimetry of the Full Visual Field in Patients With Glaucoma With Mild Visual Loss
    Wall, Michael
    Lee, Eric J.
    Wanzek, Robert J.
    Zamba, K. D.
    Turpin, Andrew
    Chong, Luke X.
    Marin-Franch, Ivan
    JOURNAL OF GLAUCOMA, 2019, 28 (11) : 997 - 1005
  • [24] SCREENING FOR GLAUCOMATOUS VISUAL-FIELD LOSS WITH AUTOMATED THRESHOLD PERIMETRY
    SOMMER, A
    ENGER, C
    WITT, K
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1987, 103 (05) : 681 - 684
  • [25] PUPIL PERIMETRY
    KARDON, RH
    CURRENT OPINION IN OPHTHALMOLOGY, 1992, 3 (05) : 565 - 570
  • [26] Frequency doubling perimetry as a means of screening for glaucomatous visual field loss
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2030 - 2030
  • [27] Frequency doubling technology perimetry for detection of glaucomatous visual field loss
    Cello, KE
    Nelson-Quigg, JM
    Johnson, CA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) : 314 - 322
  • [28] Clinical classification of glaucomatous visual field loss by frequency doubling perimetry
    Sponsel, WE
    Arango, S
    Trigo, Y
    Mensah, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (06) : 830 - 836
  • [29] Screening for glaucomatous visual field loss with frequency-doubling perimetry
    Johnson, CA
    Samuels, SJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (02) : 413 - 425
  • [30] Frequency doubling technology perimetry for the detection of glaucomatous visual field loss
    Alward, WLM
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) : 376 - 378