Threshold Automated Perimetry of the Full Visual Field in Patients With Glaucoma With Mild Visual Loss

被引:4
|
作者
Wall, Michael [1 ,2 ]
Lee, Eric J. [1 ]
Wanzek, Robert J. [1 ]
Zamba, K. D. [3 ]
Turpin, Andrew [4 ]
Chong, Luke X. [5 ]
Marin-Franch, Ivan [6 ]
机构
[1] Univ Iowa, Coll Med, Dept Ophthalmol, Vet Adm Hosp, Iowa City, IA 52242 USA
[2] Univ Iowa, Coll Med, Dept Neurol, Vet Adm Hosp, Iowa City, IA 52242 USA
[3] Univ Iowa, Coll Publ Hlth, Dept Biostat, Iowa City, IA USA
[4] Univ Melbourne, Sch Comp & Informat Syst, Melbourne, Vic, Australia
[5] Deakin Univ, Sch Med Optometry, Geelong, Vic, Australia
[6] Computat Optometry, Granada, Spain
关键词
glaucoma; perimetry; visual field; vision testing; EFFECTIVE DYNAMIC RANGES; STIMULUS SIZES III; OCULAR-SAFETY; PROGRESSION; STANDARD; PATTERN; SITA; VARIABILITY; SENSITIVITY; VIGABATRIN;
D O I
10.1097/IJG.0000000000001372
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: The authors used the Open Perimetry Interface to design a static automated perimetry test of the full field. Abnormal test locations in the nasal midperiphery and temporal inferior sector area best separated glaucomas from normals. Purpose: The peripheral visual field in glaucoma outside 30 degrees is largely unexplored with static perimetry. Their goal was to use threshold static automated perimetry to characterize the visual loss in glaucoma of the central 30 degrees and the far periphery. Patients and Methods: The authors administered the 30-2 perimetric test to 27 patients with early stage glaucoma (with mean deviation better than -4 dB) with the Goldmann III and V stimulus sizes and a custom test from 30 to up to 87 degrees with the size V stimulus twice within a month. The authors quantified (1) the retest variability, (2) the proportion of patients flagged as abnormal (at level 0.05) on the basis of pointwise probability distributions obtained from 63 ocular healthy observers, (3) the pointwise statistical distance using the Kullback-Leibler divergence between normal and glaucoma eyes, and (4) the effect of eccentricity on visual loss. Results: Size V 30-2 testing identified significantly more abnormal test locations (36%) than size III 30-2 (30%; P=0.004). Kullback-Leibler divergence between healthy and glaucoma distributions was greatest for the nasal midperipheral test locations and the inferior temporal sector area. A more pronounced decrease was found in visual sensitivity with eccentricity in the patients with glaucoma compared with the ocular healthy participants across the full visual field (P<0.001). Conclusions: Patients with glaucoma demonstrate a systematic decrease in sensitivity with eccentricity across the full visual field. Goldmann size V stimuli better detected visual loss in patients with glaucoma with mild loss than size III.
引用
收藏
页码:997 / 1005
页数:9
相关论文
共 50 条
  • [1] Depth of Visual Field Loss Using Threshold Automated Perimetry Increases with Eccentricity in Glaucoma Subjects
    Wanzek, Robert
    Lee, Eric
    Eden, Trina
    Turpin, Andrew
    Chong, Luke
    Wall, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] Temporal Wedge Defects in Glaucoma: Structure/Function Correlation With Threshold Automated Perimetry of the Full Visual Field
    Wall, Michael
    Lee, Eric J.
    Wanzek, Robert J.
    Chong, Luke X.
    Turpin, Andrew
    JOURNAL OF GLAUCOMA, 2020, 29 (03) : 191 - 197
  • [3] SCREENING FOR GLAUCOMATOUS VISUAL-FIELD LOSS WITH AUTOMATED THRESHOLD PERIMETRY
    SOMMER, A
    ENGER, C
    WITT, K
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1987, 103 (05) : 681 - 684
  • [4] AUTOMATED THRESHOLD PERIMETRY OF THE PERIPHERAL NASAL VISUAL-FIELD IN EARLY GLAUCOMA
    CONTESTABILE, MT
    SUPPRESSA, F
    FORMICHELLI, I
    GIORGI, D
    RECUPERO, SM
    ANNALS OF OPHTHALMOLOGY, 1994, 26 (05): : 200 - 204
  • [5] Threshold Static Automated Perimetry of the Full Visual Field in Idiopathic Intracranial Hypertension
    Wall, Michael
    Subramani, Ashwin
    Chong, Luke X.
    Galindo, Ramon
    Thrpin, Andrew
    Kardon, Randy H.
    Thurtell, Matthew J.
    Bailey, Jane A.
    Marin-Franch, Ivan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (06) : 1898 - 1905
  • [6] AUTOMATED DIFFERENTIAL THRESHOLD PERIMETRY FOR DETECTING GLAUCOMATOUS VISUAL-FIELD LOSS
    DUGGAN, C
    SOMMER, A
    AUER, C
    BURKHARD, K
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 100 (03) : 420 - 423
  • [7] COURSE OF VISUAL-FIELD LOSS ON AUTOMATED PERIMETRY IN CHRONIC GLAUCOMA STABILIZED BY TRABECULECTOMY
    BOISSONNOT, M
    HIRSCH, AL
    ROVIRA, JC
    RISSE, JF
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1992, 15 (12): : 645 - 650
  • [8] Threshold visual field assessment using eye-tracking perimetry compared to standard automated perimetry in glaucoma.
    Tatham, Andrew J.
    Murray, Ian
    Perperidis, Antonios
    Cameron, Lorraine
    McTrusty, Alice
    Brash, Harry
    Fleck, Brian
    Minns, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [9] The relationship of visual threshold and reaction time to visual field eccentricity with conventional automated perimetry
    Wall, M
    Kutzko, KE
    Chauhan, BC
    VISION RESEARCH, 2002, 42 (06) : 781 - 787
  • [10] PERIPHERAL VISUAL-FIELD TESTING BY AUTOMATED KINETIC PERIMETRY IN GLAUCOMA
    STEWART, WC
    SHIELDS, MB
    OLLIE, AR
    ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (02) : 202 - 206