3D numerical investigation of turbulent forced convection in a double-pipe heat exchanger with flat inner pipe

被引:56
|
作者
Do Huu-Quan [1 ]
Rostami, Ali Mohammad [2 ]
Rad, Mozafar Shokri [3 ]
Izadi, Mohsen [3 ,4 ,5 ]
Hajjar, Ahmad [6 ]
Xiong, Qingang [7 ]
机构
[1] Ton Duc Thang Univ, Fac Math & Stat, Ho Chi Minh City, Vietnam
[2] Islamic Azad Univ, Mech Engn Dept, Bushehr Branch, Bushehr, Iran
[3] Duy Tan Univ, Inst Res & Dev, Da Nang 550000, Vietnam
[4] Duy Tan Univ, Fac Elect Elect Engn, Da Nang 550000, Vietnam
[5] Lorestan Univ, Fac Engn, Mech Engn Dept, Khorramabad, Iran
[6] Univ Lyon, Mat & Struct Dept, ECAM Lyon, Lyon, France
[7] Gen Motors, IT Innovat Ctr, Warren, MI 48092 USA
关键词
Double-pipe heat exchanger; Flat inner pipe; Turbulent forced convection; Pressure drop; Heat transfer; Aspect ratio; PRESSURE-DROP CHARACTERISTICS; LONGITUDINAL VORTEX GENERATOR; TRANSFER ENHANCEMENT; FLUID-FLOW; PERFORMANCE; FIN; NANOFLUID; PARALLEL; FINLESS; TUBES;
D O I
10.1016/j.applthermaleng.2020.116106
中图分类号
O414.1 [热力学];
学科分类号
摘要
Clear understanding of the characteristics on convective heat transfer in simple-configuration double-pipe heat exchangers will add great value to design of heat exchangers. In this work, an important while less investigated problem, i.e., turbulent forced convective heat transfer inside novel double-pipe heat exchangers with flat inner pipes, was investigated through CFD. The numerical prediction was first validated with available data. Then, effects of inner pipe geometry on flow and heat transfer were investigated. It was mainly found that effects of inner pipe geometry on thermal characteristics heavily depend on the value of Re-pipe. For Re-pipe < 7000, using flat inner pipes with small aspect ratio is beneficial to overall heat transfer, thermal effectiveness, and performance index. About 2.9%, 2.7%, and 16.8% increases in overall convective heat transfer coefficient, thermal effectiveness, and performance index, respectively, were achieved for a flat inner pipe with aspect ratio of 0.37. However, for Re-pipe > 7000, circular inner pipe significantly outperforms than flat inner ones. These results imply that at low Reynolds numbers, utilization of flat inner pipes with small aspect ratio is preferred to performance improvement for double-pipe heat exchangers, while circular inner pipe is still the best choice at high Reynolds numbers.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Numerical and experimental investigation of alumina-based nanofluid effects on double-pipe heat exchanger thermal performances
    A. Bendaraa
    My. M. Charafi
    A. Hasnaoui
    SN Applied Sciences, 2021, 3
  • [42] Numerical study on forced convection heat transfer of TiO2/water nanofluid flow inside a double-pipe heat exchanger with spindle-shaped turbulators
    Izadi, Mohsen
    Alshehri, Hashim M.
    Hosseinzadeh, Fazel
    Rad, Mozafar Shokri
    Hamida, Mohamed Bechir Ben
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2023, 150 : 612 - 623
  • [43] Numerical and Experimental Investigation of Heat Transfer Enhancement in Double Pipe Heat Exchanger
    Khalaf, B. S.
    Falih, A. H.
    INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING AND SCIENCE, 2018, 454
  • [44] Mixed convection in a vertical double pipe heat exchanger
    Voicu, I.
    Mare, T.
    Galanis, N.
    Miriel, J.
    Colda, I.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2007, 46 (06) : 540 - 550
  • [45] Experimental and numerical study on heat transfer enhancement using ultrasonic vibration in a double-pipe heat exchanger
    Setareh, Milad
    Saffar-Avval, Majid
    Abdullah, Amir
    APPLIED THERMAL ENGINEERING, 2019, 159
  • [46] A numerical investigation of the heat transfer characteristics of water-based mango bark nanofluid flowing in a double-pipe heat exchanger
    Onyiriuka, E. J.
    Ighodaro, O. O.
    Adelaja, A. O.
    Ewim, D. R. E.
    Bhattacharyya, S.
    HELIYON, 2019, 5 (09)
  • [47] TRANSIENT ANALYSIS OF DOUBLE-PIPE HEAT-EXCHANGER COUPLED TO FLAT-PLATE SOLAR COLLECTOR
    YADAV, YP
    TIWARI, GN
    ENERGY CONVERSION AND MANAGEMENT, 1987, 27 (01) : 15 - 19
  • [48] Heat transfer enhancement on shells of double-pipe exchanger with double helix fins
    Li, Yaxia
    Zhang, Teng
    Zhang, Chunmei
    Zhang, Li
    Wu, Jianhua
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2016, 35 (04): : 1042 - 1046
  • [49] Employing uniform and non-uniform inner twisted elliptical tubes in a double-pipe heat exchanger
    Azizi, Aliakbar Sheikhi
    Jahanian, Omid
    Ajarostaghi, Seyed Soheil Mousavi
    Arici, Muslum
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2024, 107
  • [50] Numerical analysis reliability control for a double-pipe heat exchanger with virtual entropy generation method
    Tavangar, Tooran
    Amoli, Behzad Siavash
    Delavar, Mojtaba Aghajani
    HEAT TRANSFER-ASIAN RESEARCH, 2019, 48 (05): : 1933 - 1945