3D numerical investigation of turbulent forced convection in a double-pipe heat exchanger with flat inner pipe

被引:56
|
作者
Do Huu-Quan [1 ]
Rostami, Ali Mohammad [2 ]
Rad, Mozafar Shokri [3 ]
Izadi, Mohsen [3 ,4 ,5 ]
Hajjar, Ahmad [6 ]
Xiong, Qingang [7 ]
机构
[1] Ton Duc Thang Univ, Fac Math & Stat, Ho Chi Minh City, Vietnam
[2] Islamic Azad Univ, Mech Engn Dept, Bushehr Branch, Bushehr, Iran
[3] Duy Tan Univ, Inst Res & Dev, Da Nang 550000, Vietnam
[4] Duy Tan Univ, Fac Elect Elect Engn, Da Nang 550000, Vietnam
[5] Lorestan Univ, Fac Engn, Mech Engn Dept, Khorramabad, Iran
[6] Univ Lyon, Mat & Struct Dept, ECAM Lyon, Lyon, France
[7] Gen Motors, IT Innovat Ctr, Warren, MI 48092 USA
关键词
Double-pipe heat exchanger; Flat inner pipe; Turbulent forced convection; Pressure drop; Heat transfer; Aspect ratio; PRESSURE-DROP CHARACTERISTICS; LONGITUDINAL VORTEX GENERATOR; TRANSFER ENHANCEMENT; FLUID-FLOW; PERFORMANCE; FIN; NANOFLUID; PARALLEL; FINLESS; TUBES;
D O I
10.1016/j.applthermaleng.2020.116106
中图分类号
O414.1 [热力学];
学科分类号
摘要
Clear understanding of the characteristics on convective heat transfer in simple-configuration double-pipe heat exchangers will add great value to design of heat exchangers. In this work, an important while less investigated problem, i.e., turbulent forced convective heat transfer inside novel double-pipe heat exchangers with flat inner pipes, was investigated through CFD. The numerical prediction was first validated with available data. Then, effects of inner pipe geometry on flow and heat transfer were investigated. It was mainly found that effects of inner pipe geometry on thermal characteristics heavily depend on the value of Re-pipe. For Re-pipe < 7000, using flat inner pipes with small aspect ratio is beneficial to overall heat transfer, thermal effectiveness, and performance index. About 2.9%, 2.7%, and 16.8% increases in overall convective heat transfer coefficient, thermal effectiveness, and performance index, respectively, were achieved for a flat inner pipe with aspect ratio of 0.37. However, for Re-pipe > 7000, circular inner pipe significantly outperforms than flat inner ones. These results imply that at low Reynolds numbers, utilization of flat inner pipes with small aspect ratio is preferred to performance improvement for double-pipe heat exchangers, while circular inner pipe is still the best choice at high Reynolds numbers.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Direct numerical simulation of turbulent forced convection in a pipe
    Piller, M
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2005, 49 (06) : 583 - 602
  • [32] Measuring Local Crystallization Fouling in a Double-Pipe Heat Exchanger
    Schlueter, Florian
    Schnoeing, Lukas
    Zettler, Hans
    Augustin, Wolfgang
    Scholl, Stephan
    HEAT TRANSFER ENGINEERING, 2020, 41 (02) : 149 - 159
  • [33] What dominates heat transfer performance of a double-pipe heat exchanger
    Zheng, Dan
    Hu, Zhenwei
    Tian, Liting
    Wang, Jin
    Sunden, Bengt
    OPEN PHYSICS, 2021, 19 (01): : 863 - 866
  • [34] EFFECTS OF BUOYANCY ON THE PERFORMANCE OF A VERTICAL DOUBLE-PIPE HEAT EXCHANGER
    Voicu, Ionut
    Galanis, Nicolas
    Mare, Thierry
    COMPUTATIONAL THERMAL SCIENCES, 2011, 3 (05): : 345 - 357
  • [35] Performance of double-pipe heat exchanger enhanced by helical fins
    Wang, D. (wangdb@zzu.edu.cn), 1600, Materials China (65):
  • [36] Numerical design and investigation of heat transfer enhancement and performance for an annulus with continuous helical baffles in a double-pipe heat exchanger
    El Maakoul, Anas
    Laknizi, Azzeddine
    Saadeddine, Said
    Ben Abdellah, Abdellatif
    Meziane, Mohamed
    El Metoui, Mustapha
    ENERGY CONVERSION AND MANAGEMENT, 2017, 133 : 76 - 86
  • [37] Thermoeconomical optimization of double-pipe heat exchanger for waste heat recovery
    Söylemez, AS
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2004, 18 (04) : 559 - 563
  • [38] Thermal management of double-pipe air to water heat exchanger
    Sheikholeslami, Mohsen
    Hatami, M.
    Jafaryar, M.
    Farkhadnia, F.
    Ganji, Davood Domiri
    Gorji-Bandpy, Mad
    ENERGY AND BUILDINGS, 2015, 88 : 361 - 366
  • [39] Thermally developing flow in finned double-pipe heat exchanger
    Iqbal, Mazhar
    Syed, K. S.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2011, 65 (10) : 1145 - 1159
  • [40] Numerical and experimental investigation of alumina-based nanofluid effects on double-pipe heat exchanger thermal performances
    Bendaraa, A.
    Charafi, My. M.
    Hasnaoui, A.
    SN APPLIED SCIENCES, 2021, 3 (02):