A contactless conductivity detector for capillary electrophoresis:: Effects of the detection cell geometry on the detector performance

被引:0
|
作者
Tuma, P [1 ]
Opekar, F [1 ]
Stulík, K [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, UNESCO, Lab Environm Electrochem, CZ-12843 Prague 2, Czech Republic
关键词
capillary electrophoresis; conductometric detection; contactless detection; detection cell geometry;
D O I
10.1002/1522-2683(200211)23:21<3718::AID-ELPS3718>3.0.CO;2-U
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of the gap between the electrodes and of their width on the behavior of a capacitively wired contactless conductivity detector was studied. The results obtained have indicated that the detector response can be qualitatively described by a model based on the concept of the effective electrode width which is a complex parameter determined by the gap between the electrodes, the frequency of the input signal and the conductivity of the test solution. The detector sensitivity and the effect on the separation efficiency depend on the difference between the effective and geometric electrode widths. Higher detection sensitivities have been attained for detectors with wide electrodes operating at lower frequencies, however, better separation efficiencies have been achieved using detectors with narrow electrodes and higher operational frequencies. The noise increases with decreasing gap between the electrodes and increasing frequency, especially with detectors employing narrow electrodes.
引用
收藏
页码:3718 / 3724
页数:7
相关论文
共 50 条
  • [12] Application of an external contactless conductivity detector for the analysis of beverages by microchip capillary electrophoresis
    Kubán, P
    Hauser, PC
    ELECTROPHORESIS, 2005, 26 (16) : 3169 - 3178
  • [13] Determination of amino acids by capillary electrophoresis with differential resonant contactless conductivity detector
    Shen, Dazhong
    Li, Yaolong
    Zhang, Zhenli
    Zhang, Ping
    Kang, Qi
    TALANTA, 2013, 104 : 39 - 43
  • [14] Fluorescence detection in capillary electrophoresis: Detector cell
    Kaizu, T
    Kim, D
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1999, 119 (09): : 674 - 680
  • [15] Effect of the Detector Parameters on the Sensitivity of Contactless Conductivity Detector for Micrchip electrophoresis
    Zhang, Haifeng
    Liu, Xiaowei
    Li, Haitao
    Wang, Xilian
    7TH INTERNATIONAL CONFERENCE ON SYSTEM SIMULATION AND SCIENTIFIC COMPUTING ASIA SIMULATION CONFERENCE 2008, VOLS 1-3, 2008, : 355 - +
  • [16] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Schnell, E
    Volgger, D
    Bonn, GK
    ANALYTICAL CHEMISTRY, 1998, 70 (03) : 563 - 567
  • [17] A New Conductivity Detector for Capillary Electrophoresis
    Zuan Guang CHEN
    Jin Yuan MO
    Tian Yao XIE
    Li Shi WANG
    Xiao Yun YANG
    Kong ZHANG
    Min Sheng ZHANG (Department of Chemistry. Sun Yat-sen University of Medical Sciences. Guangzhou 510089 College of Chemistry and Chemical Engineering. Zhongshan University.
    Chinese Chemical Letters, 2000, (05) : 439 - 442
  • [18] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Mayrhofer, K
    Schnell, E
    Bonn, GK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U162 - U162
  • [19] A new conductivity detector for capillary electrophoresis
    Chen, ZG
    Mo, JY
    Xie, TY
    Wang, LS
    Yang, XY
    Zhang, K
    Zhang, MS
    CHINESE CHEMICAL LETTERS, 2000, 11 (05) : 439 - 442
  • [20] A contactless conductometric detector with easily exchangeable capillary for capillary electrophoresis
    Tuma, P
    Opekar, F
    Jelínek, I
    ELECTROANALYSIS, 2001, 13 (12) : 989 - 992