A new conductivity detector for capillary electrophoresis

被引:0
|
作者
Chen, ZG
Mo, JY
Xie, TY
Wang, LS
Yang, XY
Zhang, K
Zhang, MS
机构
[1] Sun Yat Sen Univ, Dept Chem, Guangzhou 510089, Peoples R China
[2] Zhongshan Univ, Coll Chem & Chem Engn, Canton 510275, Peoples R China
[3] Sun Yat Sen Univ Med Sci, Attached Hosp 1, Guangzhou 510080, Peoples R China
关键词
capillary electrophoresis; conductivity detector;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new conductivity detector for capillary electrophoresis consisting of an electrochemical cell and a conductive meter was developed. In the cell, the microelectrode and capillaryd were inserted through the cell wall and fixed by screws and sealing ring, the ends of microelectrode: and capillary were located by a guide with two cross holes. LOD for K+ was 1.5 x 10(-5) mol/L.
引用
收藏
页码:439 / 442
页数:4
相关论文
共 50 条
  • [1] A New Conductivity Detector for Capillary Electrophoresis
    Zuan Guang CHEN
    Jin Yuan MO
    Tian Yao XIE
    Li Shi WANG
    Xiao Yun YANG
    Kong ZHANG
    Min Sheng ZHANG (Department of Chemistry. Sun Yat-sen University of Medical Sciences. Guangzhou 510089 College of Chemistry and Chemical Engineering. Zhongshan University.
    Chinese Chemical Letters, 2000, (05) : 439 - 442
  • [2] Contactless conductivity detector for microchip capillary electrophoresis
    Pumera, M
    Wang, J
    Opekar, F
    Jelínek, I
    Feldman, J
    Löwe, H
    Hardt, S
    ANALYTICAL CHEMISTRY, 2002, 74 (09) : 1968 - 1971
  • [3] High Frequency Conductivity Detector for Capillary Electrophoresis
    Chen, Zuan-Guang
    Mo, Jin-Yuan
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 2002, 23 (05):
  • [4] High frequency conductivity detector for capillary electrophoresis
    Chen, ZG
    Mo, JY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2002, 23 (05): : 801 - 804
  • [5] Contactless conductivity detector for capillary electrophoresis chip
    Liu, Xiao-Wei
    Zhang, Hai-Feng
    Shao, Xian-Hui
    Li, Ling
    Peng, Zhi-Cheng
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2009, 7 (02): : 123 - 126
  • [6] Contactless conductivity detector array for capillary electrophoresis
    Stojkovic, Marko
    Koenka, Israel Joel
    Thormann, Wolfgang
    Hauser, Peter C.
    ELECTROPHORESIS, 2014, 35 (04) : 482 - 486
  • [7] Referenced Capacitively Coupled Conductivity Detector for Capillary Electrophoresis
    Stojkovic, Marko
    Schlensky, Boris
    Hauser, Peter C.
    ELECTROANALYSIS, 2013, 25 (12) : 2645 - 2650
  • [8] Improved capacitively coupled conductivity detector for capillary electrophoresis
    Tanyanyiwa, J
    Galliker, B
    Schwarz, MA
    Hauser, PC
    ANALYST, 2002, 127 (02) : 214 - 218
  • [9] ON-COLUMN CONDUCTIVITY DETECTOR FOR CAPILLARY ZONE ELECTROPHORESIS
    HUANG, XH
    PANG, TKJ
    GORDON, MJ
    ZARE, RN
    ANALYTICAL CHEMISTRY, 1987, 59 (23) : 2747 - 2749
  • [10] Miniaturized capillary electrophoresis system with integrated conductivity detector
    Schasfoort, R
    Guijt-van Duijn, R
    Schlautmann, S
    Frank, H
    Billiet, H
    van Dedem, G
    van den Berg, A
    MICRO TOTAL ANALYSIS SYSTEMS 2000, PROCEEDINGS, 2000, : 391 - 394