Determination of hydrogen peroxide by micro-flow injection-chemiluminescence using a coupled flow cell reactor chemiluminometer

被引:0
|
作者
Nozaki, O
Kawamoto, H
机构
[1] Kinki Univ, Sch Med, Dept Clin Pathol, Osaka 5898511, Japan
[2] Tottori Univ, Coll Med Technol, Dept Med Technol, Tottori 6830826, Japan
关键词
flow cell reactor; luminol; micro-flow injection-chemiluminescence; hydrogen peroxide; immobilized horseradish peroxidase;
D O I
10.1002/1522-7243(200005/06)15:3<137::AID-BIO576>3.0.CO;2-J
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel flow cell reactor was developed for micro-flow injection determination of hydrogen peroxide (H2O2) using horseradish peroxide (HRP)-catalysed luminol chemiluminescence. The newly developed how cell reactor for a chemiluminometer allowed mixing of the chemiluminescent reagents in front of a photomultiplier for maximum detection of the emitted light. The rapid mixing allowed a decrease in the flow rate of the pump to 0.1-0.01 mL/min, resulting in increased sensitivity of detection of light. The how cell reactor was made by packing HRP-immobilized gels into a flow cell (Teflon tube; 6 cm x 0.98 mm i.d.) located in the cell holder of a chemiluminometer (flow-through type). The HRP-immobilized gels were made by immobilizing HRP onto the Chitopearl gel by the periodate method. H2O2 specimens (50 mu L) were injected into a stream of water delivered at a how rate of 0.1 mL/min and mixed with a luminol solution (0.56 mmol/L in Tricine buffer, pH 9.2) delivered at 0.1 mL/min in the flow cell reactor. Within-run reproducibility of the assay of H2O2 was 2.4% (4.85 mu mol/L; flow rate 0.1 mL/min, injection interval 10 min). The reproducibility of the H2O2 assay was influenced by the flow rates and the injection intervals of the H2O2 specimens. As the flow rates decreased, both the light intensity and the light duration increased. Optimal light intensity was obtained at a luminol concentration of 3-8 mmol/L, but 0.56 mmol/L was sufficient for assay of H2O2 in clinical specimens. At a luminol concentration of 0.56 mmol/L, the regression equation of the standard curve for H2O2 (0-9.7 mu mol/L) was Y = 27.5 X-2 + 394 X + 58.9 (Y = light intensity; X = concentration of H2O2) and the detection limit of H2O2 was 0.2 mu mol/L. This method was used to assay glucose (2.7-16.7 mmol/L) based on a glucose oxidase (20 U/mL, pH 7.4) reaction. The standard curve for glucose was Y = 167 X-2 - 351 X + 1484 (Y = light intensity; X = glucose). The within-run reproducibility for an aqueous glucose standard (2.7 mmol/L) and a control serum (glucose, 5 mmol/L) was 4.48% (n = 5) and 5.70% (n = 9), respectively. Copyright (C) 2000 John Wiley & Sons, Ltd.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 50 条
  • [41] Determination of bismuth by flow injection coupled chemiluminescence reaction
    Fan, Shun-Li
    Wu, Zhi-Hao
    Lihua Jianyan: Huaxue Fence/Physical Testing and Chemical Analysis Part B:Chemical Analysis, 2003, 39 (07):
  • [42] Determination of gallium by flow injection coupled chemiluminescence reaction
    Li, WH
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (12) : 1447 - 1449
  • [43] A Novel Enhancing Flow-Injection Chemiluminescence Method for the Determination of Glutathione Using the Reaction of Luminol with Hydrogen Peroxide
    Lun Wang
    Yongxin Li
    Danhua Zhao
    Changqin Zhu
    Microchimica Acta, 2003, 141 : 41 - 45
  • [44] A novel enhancing flow-injection chemiluminescence method for the determination of glutathione using the reaction of luminol with hydrogen peroxide
    Wang, L
    Li, YX
    Zhao, DH
    Zhu, CQ
    MICROCHIMICA ACTA, 2003, 141 (1-2) : 41 - 45
  • [45] Chemiluminescence micro-flow system for rapid determination of chemical oxygen demand in water
    Liu, Wei
    Zhang, Zhujun
    Zhang, Youyi
    MICROCHIMICA ACTA, 2008, 160 (1-2) : 141 - 146
  • [46] Automatic sampler coupled with flow injection-chemiluminescence detection to monitor particle/natural water interactions
    Seguret, Marie J. M.
    Ussher, Simon J.
    Worsfold, Paul J.
    Nimmo, Malcolm
    Wood, John W.
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2008, 36 (01) : 18 - 31
  • [47] Chemiluminescence micro-flow system for rapid determination of chemical oxygen demand in water
    Wei Liu
    Zhujun Zhang
    Youyi Zhang
    Microchimica Acta, 2008, 160 : 141 - 146
  • [48] Differential amperometric determination of hydrogen peroxide in honeys using flow-injection analysis with enzymatic reactor
    de Abreu Franchini, Romulo Augusto
    Costa Matos, Maria Auxiliadora
    Colombara, Rosana
    Matos, Renato Camargo
    TALANTA, 2008, 75 (01) : 301 - 306
  • [49] Determination of hydrogen peroxide in natural waters by stopped-flow injection analysis with chemiluminescence detection
    Fan, SH
    Hart, BT
    McKelvie, ID
    LABORATORY ROBOTICS AND AUTOMATION, 2000, 12 (03) : 149 - 156
  • [50] DETERMINATION OF HYDROGEN-PEROXIDE IN REACTOR MODERATOR SOLUTIONS BY FLOW-INJECTION ANALYSIS
    WHITAKER, MJ
    TALANTA, 1993, 40 (01) : 113 - 117