Determination of hydrogen peroxide by micro-flow injection-chemiluminescence using a coupled flow cell reactor chemiluminometer

被引:0
|
作者
Nozaki, O
Kawamoto, H
机构
[1] Kinki Univ, Sch Med, Dept Clin Pathol, Osaka 5898511, Japan
[2] Tottori Univ, Coll Med Technol, Dept Med Technol, Tottori 6830826, Japan
关键词
flow cell reactor; luminol; micro-flow injection-chemiluminescence; hydrogen peroxide; immobilized horseradish peroxidase;
D O I
10.1002/1522-7243(200005/06)15:3<137::AID-BIO576>3.0.CO;2-J
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel flow cell reactor was developed for micro-flow injection determination of hydrogen peroxide (H2O2) using horseradish peroxide (HRP)-catalysed luminol chemiluminescence. The newly developed how cell reactor for a chemiluminometer allowed mixing of the chemiluminescent reagents in front of a photomultiplier for maximum detection of the emitted light. The rapid mixing allowed a decrease in the flow rate of the pump to 0.1-0.01 mL/min, resulting in increased sensitivity of detection of light. The how cell reactor was made by packing HRP-immobilized gels into a flow cell (Teflon tube; 6 cm x 0.98 mm i.d.) located in the cell holder of a chemiluminometer (flow-through type). The HRP-immobilized gels were made by immobilizing HRP onto the Chitopearl gel by the periodate method. H2O2 specimens (50 mu L) were injected into a stream of water delivered at a how rate of 0.1 mL/min and mixed with a luminol solution (0.56 mmol/L in Tricine buffer, pH 9.2) delivered at 0.1 mL/min in the flow cell reactor. Within-run reproducibility of the assay of H2O2 was 2.4% (4.85 mu mol/L; flow rate 0.1 mL/min, injection interval 10 min). The reproducibility of the H2O2 assay was influenced by the flow rates and the injection intervals of the H2O2 specimens. As the flow rates decreased, both the light intensity and the light duration increased. Optimal light intensity was obtained at a luminol concentration of 3-8 mmol/L, but 0.56 mmol/L was sufficient for assay of H2O2 in clinical specimens. At a luminol concentration of 0.56 mmol/L, the regression equation of the standard curve for H2O2 (0-9.7 mu mol/L) was Y = 27.5 X-2 + 394 X + 58.9 (Y = light intensity; X = concentration of H2O2) and the detection limit of H2O2 was 0.2 mu mol/L. This method was used to assay glucose (2.7-16.7 mmol/L) based on a glucose oxidase (20 U/mL, pH 7.4) reaction. The standard curve for glucose was Y = 167 X-2 - 351 X + 1484 (Y = light intensity; X = glucose). The within-run reproducibility for an aqueous glucose standard (2.7 mmol/L) and a control serum (glucose, 5 mmol/L) was 4.48% (n = 5) and 5.70% (n = 9), respectively. Copyright (C) 2000 John Wiley & Sons, Ltd.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 50 条
  • [31] Flow Injection-Chemiluminescence Method for Determination of Hyoscine Butylbromide Using Silver(III) as Oxidizing Agent
    Ahmed, Madzoor
    Asghar, Muhammad
    Yaqoob, Mohammad
    Munawar, Nusrat
    Shahid, Farkhanda
    Asad, Mida
    Nabi, Abdul
    ANALYTICAL SCIENCES, 2017, 33 (11) : 1259 - 1263
  • [32] Development of a sensitive flow injection-chemiluminescence detection method for the indirect determination of propranolol
    Tsogas, GZ
    Stergiou, DV
    Vlessidis, AG
    Evmiridis, NP
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 151 - 157
  • [33] Determination of hydrogen peroxide in water by chemiluminescence detection, (I) flow injection type hydrogen peroxide detection system
    Yamashiro, N
    Uchida, S
    Satoh, Y
    Morishima, Y
    Yokoyama, H
    Satoh, T
    Sugama, J
    Yamada, R
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2004, 41 (09) : 890 - 897
  • [34] Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Tomás, V
    Martín, J
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (01) : 189 - 194
  • [35] Determination of monocrotophos pesticide by flow injection chemiluminescence method using luminol-hydrogen peroxide system
    Du, JX
    Liu, XY
    Lu, JR
    ANALYTICAL LETTERS, 2003, 36 (05) : 1029 - 1038
  • [36] Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection
    Tomás Pérez-Ruiz
    Carmen Martínez-Lozano
    Virginia Tomás
    Jesús Martín
    Analytical and Bioanalytical Chemistry, 2003, 377 : 189 - 194
  • [37] Determination of hydrogen peroxide in sea water by flow-injection analysis with chemiluminescence detection
    Price, D.
    Worsfold, P. J.
    Fauzi, R.
    Mantoura, C.
    International Sugar Journal, 978
  • [38] Analytical intercomparison between flow injection-chemiluminescence and flow injection-spectrophotometry for the determination of picomolar concentrations of iron in seawater
    Bowie, AR
    Sedwick, PN
    Worsfold, PJ
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2004, 2 : 42 - 54
  • [39] Determination of tyrosine using flow injection analysis coupled with chemiluminescence detection
    Zhang, XY
    Fan, XD
    Gao, X
    Zhang, FY
    Zhang, Q
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (12) : 1693 - 1693
  • [40] Flow injection analysis of hydrogen peroxide with peroxyoxalate chemiluminescence detection
    Nabi, A
    Rashid, A
    Yaqoob, M
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 1996, 18 (03): : 211 - 214