Energy response of GR-200A thermoluminescence dosemeters to 60Co and to monoenergetic synchrotron radiation in the energy range 28-40 keV

被引:4
|
作者
Emiro, F. [1 ,2 ]
Di Lillo, F. [1 ,2 ]
Mettivier, G. [1 ,2 ]
Fedon, C. [3 ,4 ]
Longo, R. [3 ,4 ]
Tromba, G. [5 ]
Russo, P. [1 ,2 ]
机构
[1] Univ Naples Federico II, Dipartimento Fis, Via Cintia, I-80126 Naples, Italy
[2] Ist Nazl Fis Nucl, Sez Napoli, Via Cintia, I-80126 Naples, Italy
[3] Univ Trieste, Dipartimento Fis, Via A Valerio 2, I-34127 Trieste, Italy
[4] Ist Nazl Fis Nucl, Sez Trieste, Via A Valerio 2, I-34127 Trieste, Italy
[5] Sincrotrone Trieste SCpA, Str Statale SS 14 Km 163-5, I-34012 Trieste, Italy
关键词
DOSE-RESPONSE; DETECTORS; PHOTONS;
D O I
10.1093/rpd/ncv014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The response of LiF:Mg,Cu,P thermoluminescence dosemeters (type GR-200A) to monoenergetic radiation of energy 28, 35, 38 and 40 keV was evaluated with respect to irradiation with a calibrated Co-60 gamma-ray source. High-precision measurements of the relative air kerma response performed at the SYRMEP beamline of the ELETTRA synchrotron radiation facility (Trieste, Italy) showed a significant deviation of the average response to low-energy X-rays from that to Co-60, with an over-response from 6 % (at 28 keV) to 22 % (at 40 keV). These data are not consistent with literature data for these dosemeters, where model predictions gave deviation from unity of the relative air kerma response of about 10 %. The authors conclude for the need of additional determinations of the low-energy relative response of GR-200A dosemeters, covering a wider range of monoenergetic energies sampled at a fine energy step, as planned in future experiments by their group at the ELETTRA facility.
引用
收藏
页码:40 / 45
页数:6
相关论文
共 5 条
  • [1] The response of LiF thermoluminescence dosemeters to photon beams in the energy range from 30 kV X rays to 60Co gamma rays
    Davis, SD
    Ross, CK
    Mobit, PN
    Van der Zwan, L
    Chase, WJ
    Shortt, KR
    RADIATION PROTECTION DOSIMETRY, 2003, 106 (01) : 33 - 43
  • [2] Energy response study of thermoluminescent dosimeters to synchrotron radiation in the energy range 10-35 keV
    Bakshi, A. K.
    Dhabekar, B. S.
    Chatterjee, S.
    Joshi, V. J.
    Kher, R. K.
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2009, 16 (03) : 172 - 174
  • [3] The energy response of TLD-500K thermoluminescence detectors over the range of 12-45 keV under synchrotron radiation
    Kortov, VS
    Pustovarov, VA
    Syurdo, AI
    Zolotarev, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 405 (2-3): : 289 - 291
  • [4] Energy response of LiF:Mg,Ti thermoluminescent dosimeters to moderately filtered X-ray spectra in the range of 20 to 250 KV relative to 60Co
    Nunn, A.
    Davis, S.
    DeWerd, L.
    Micka, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2193 - 2194
  • [5] LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 20-250 kVp relative to 60Co
    Nunn, A. A.
    Davis, S. D.
    Micka, J. A.
    DeWerd, L. A.
    MEDICAL PHYSICS, 2008, 35 (05) : 1859 - 1869