LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 20-250 kVp relative to 60Co

被引:110
|
作者
Nunn, A. A. [1 ,2 ]
Davis, S. D. [1 ]
Micka, J. A. [1 ]
DeWerd, L. A. [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Anchorage Radiat Therapy Ctr, Anchorage, AK 99508 USA
关键词
thermoluminescence dosimetry; Monte Carlo; energy response; brachytherapy;
D O I
10.1118/1.2898137
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The response of LiF:Mg,Ti thermoluminescent dosimeters (TLDs) as a function of photon energy was determined using irradiations with moderately filtered x-ray beams in the energy range of 20-250 kVp relative to the response to irradiations with Co-60 photons. To determine if the relative light output from LiF:Mg,Ti TLDs per unit air kerma as a function of photon energy can be predicted using calculations such as Monte Carlo (MC) simulations, measurements from the x-ray beam irradiations were compared with MC calculated results, similar to the methodology used by Davis [Radiat. Prot. Dosim. 106, 33-43 (2003)]. TLDs were irradiated in photon beams with well-known air kerma rates using the National Institute of Standards and Technology traceable M-series x-ray beams in the range of 20-250 kVp. For each x-ray beam, several sets of TLDs were irradiated for times corresponding to different air kerma levels to take into account any dose nonlinearity. TLD light output was then compared to that from several sets of TLDs irradiated at similar corresponding air kerma levels using a Co-60 irradiator. The MC code MCNP5 was used to account for photon scatter and attenuation in the holder and TLDs and was used to calculate the predicted relative TLD light output per unit air kerma for irradiations with each of the experimentally used photon beams. The measured relative TLD response as a function of photon energy differed by up to 13% from the MC calculations. We conclude that MC calculations do not accurately predict the relative response of TLDs as a function of photon energy, consistent with the conclusions of Davis [Radiat. Prot. Dosim. 106, 33-43 (2003)]. This is likely due to complications in the solid state physics of the thermoluminescence process that are not incorporated into the simulation. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:1859 / 1869
页数:11
相关论文
共 7 条
  • [1] Energy response of LiF:Mg,Ti thermoluminescent dosimeters to moderately filtered X-ray spectra in the range of 20 to 250 KV relative to 60Co
    Nunn, A.
    Davis, S.
    DeWerd, L.
    Micka, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2193 - 2194
  • [2] Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to 60Co
    Snow, J. R.
    Micka, J. A.
    DeWerd, L. A.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [3] Combined Effect of Intrinsic Energy Dependence and Intrinsic Linearity on TLD-100 Response to Moderately Filtered 50 KVp X-Ray Spectra Relative to 60Co
    Liang, Q.
    Davis, S.
    DeWerd, L.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [4] Determination of the sensibility factors for TLD-100 powder on the energy of X-ray of 50, 250 kVp; 192Ir, 137Cs and 60Co
    Loaiza, Sandra P.
    Alvarez, Jose T.
    MEDICAL PHYSICS, 2006, 854 : 117 - +
  • [5] Influence of phantom materials on the energy dependence of LiF: Mg, Ti thermoluminescent dosimeters exposed to 20-300 kV narrow x-ray spectra, 137Cs and 60Co photons
    Massillon-JL, G.
    Cabrera-Santiago, A.
    Minniti, R.
    O'Brien, M.
    Soares, C. G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (15): : 4149 - 4166
  • [6] The response of LiF thermoluminescence dosemeters to photon beams in the energy range from 30 kV X rays to 60Co gamma rays
    Davis, SD
    Ross, CK
    Mobit, PN
    Van der Zwan, L
    Chase, WJ
    Shortt, KR
    RADIATION PROTECTION DOSIMETRY, 2003, 106 (01) : 33 - 43
  • [7] Track-average LET of secondary electrons generated in LiF:Mg,Ti and liquid water by 20-300 kV x-ray, 137Cs and 60Co beams
    Cabrera-Santiago, A.
    Massillon-JL, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (22): : 7919 - 7933