Determination of enalapril maleate and atenolol in their pharmaceutical products and in biological fluids by flow-injection chemiluminescence

被引:6
|
作者
Al-arfaj, Nawal A. [1 ]
Al-Abdulkareem, Eman A. [1 ]
Aly, Fatma A. [1 ]
机构
[1] King Saud Univ, Dept Chem, Coll Sci, Women Student Med Studies Sect, Riyadh 11495, Saudi Arabia
关键词
enalapril maleate; atenolol; chemiluminescence; Ce(IV)-sulfite reaction; pharmaceuticals; biological fluids; LIQUID-CHROMATOGRAPHY; BETA-BLOCKERS; GAS-CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; SPECTROPHOTOMETRIC METHOD; ENANTIOSELECTIVE ANALYSIS; QUANTITATIVE-ANALYSIS; HUMAN PLASMA; URINE; ASSAY;
D O I
10.1002/bio.1129
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemiluminescent method using flow injection (FI) was investigated for rapid and sensitive determination of enalapril maleate and atenolol, which are used in the treatment of hypertension. The method is based on the sensitizing effect of these drugs on the Ce(IV)-sulfite reaction. The different experimental parameters affecting the chemiluminescence (CL) intensity were carefully studied and incorporated into the procedure. The method permitted the determination of 0.01-3.0 mu g mL(-1) of enalapril maleate in bulk form with correlation coefficient r = 0.99993, lower limit of detection (LOD) 0.0025 mu g mL(-1) (S/N = 2) and lower limit of quantitation (LOQ) 0.01 mu g mL(-1). The linearity range of atenolol in bulk form was 0.01-2.0 mu g mL(-1) (r = 0.99989) with LOD of 0.0003 mu g mL(-1) (S/N = 2) and LOQ of 0.01 mu g mL(-1). In biological fluids the linearity range of enalapril maleate was 0.1-2.0 mu g mL(-1) in both urine and serum, and for atenolol the linearity range was 0.1-1.0 mu g mL(-1) in both urine and serum. The method was also applied to the determination of the drugs in their pharmaceutical preparations. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:422 / 428
页数:7
相关论文
共 50 条
  • [21] Recent progress in flow-injection chemiluminescence for pharmaceutical analysis
    Xue, Bing-Chun
    Wang, Tao
    Liu, Er-Bao
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2006, 26 (05): : 816 - 820
  • [22] Recent progress in flow-injection chemiluminescence for pharmaceutical analysis
    Xue Bing-chun
    Wang Tao
    Liu Er-bao
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26 (05) : 816 - 820
  • [23] Flow-injection chemiluminescence analysis for sensitive determination of atenolol using cadmium sulfide quantum dots
    Khataee, Alireza
    Lotfi, Roya
    Hasanzadeh, Aliyeh
    Iranifam, Mortaza
    Joo, Sang Woo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 157 : 88 - 95
  • [24] FLOW-INJECTION FLUOROMETRIC ANALYSIS OF SULFAMETHOXAZOLE IN PHARMACEUTICAL PREPARATIONS AND BIOLOGICAL-FLUIDS
    ERROZ, CL
    VINAS, P
    CORDOBA, MH
    TALANTA, 1994, 41 (12) : 2159 - 2164
  • [25] Flow injection chemiluminescence sensor for the determination of ergonovine maleate
    Gong, ZJ
    Huang, YM
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (05) : 641 - 643
  • [26] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao Zhi-ming
    Zou Ping
    Chen Mei
    Xiu Fu-rong
    Chen Yu-lin
    Hong Ke-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (02) : 269 - 272
  • [27] Flow-injection with chemiluminescence detection for the determination of iproniazid
    Alonso, MCS
    Zamora, LL
    Calatayud, JM
    ANALYTICA CHIMICA ACTA, 2001, 437 (02) : 225 - 231
  • [28] Flow-injection chemiluminescence sensor for the determination of isoniazid
    Zhang, SC
    Li, H
    ANALYTICA CHIMICA ACTA, 2001, 444 (02) : 287 - 294
  • [29] Sensitive determination of synephrine by flow-injection chemiluminescence
    Li, Q
    Huang, CZ
    Huang, YM
    LUMINESCENCE, 2006, 21 (01) : 43 - 48
  • [30] Flow-injection chemiluminescence determination of formaldehyde in water
    Motyka, Kamil
    Onjia, Antonije
    Mikuska, Pavel
    Vecera, Zbynek
    TALANTA, 2007, 71 (02) : 900 - 905