Determination of enalapril maleate and atenolol in their pharmaceutical products and in biological fluids by flow-injection chemiluminescence
被引:6
|
作者:
Al-arfaj, Nawal A.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Dept Chem, Coll Sci, Women Student Med Studies Sect, Riyadh 11495, Saudi ArabiaKing Saud Univ, Dept Chem, Coll Sci, Women Student Med Studies Sect, Riyadh 11495, Saudi Arabia
Al-arfaj, Nawal A.
[1
]
Al-Abdulkareem, Eman A.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Dept Chem, Coll Sci, Women Student Med Studies Sect, Riyadh 11495, Saudi ArabiaKing Saud Univ, Dept Chem, Coll Sci, Women Student Med Studies Sect, Riyadh 11495, Saudi Arabia
Al-Abdulkareem, Eman A.
[1
]
Aly, Fatma A.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Dept Chem, Coll Sci, Women Student Med Studies Sect, Riyadh 11495, Saudi ArabiaKing Saud Univ, Dept Chem, Coll Sci, Women Student Med Studies Sect, Riyadh 11495, Saudi Arabia
Aly, Fatma A.
[1
]
机构:
[1] King Saud Univ, Dept Chem, Coll Sci, Women Student Med Studies Sect, Riyadh 11495, Saudi Arabia
A chemiluminescent method using flow injection (FI) was investigated for rapid and sensitive determination of enalapril maleate and atenolol, which are used in the treatment of hypertension. The method is based on the sensitizing effect of these drugs on the Ce(IV)-sulfite reaction. The different experimental parameters affecting the chemiluminescence (CL) intensity were carefully studied and incorporated into the procedure. The method permitted the determination of 0.01-3.0 mu g mL(-1) of enalapril maleate in bulk form with correlation coefficient r = 0.99993, lower limit of detection (LOD) 0.0025 mu g mL(-1) (S/N = 2) and lower limit of quantitation (LOQ) 0.01 mu g mL(-1). The linearity range of atenolol in bulk form was 0.01-2.0 mu g mL(-1) (r = 0.99989) with LOD of 0.0003 mu g mL(-1) (S/N = 2) and LOQ of 0.01 mu g mL(-1). In biological fluids the linearity range of enalapril maleate was 0.1-2.0 mu g mL(-1) in both urine and serum, and for atenolol the linearity range was 0.1-1.0 mu g mL(-1) in both urine and serum. The method was also applied to the determination of the drugs in their pharmaceutical preparations. Copyright (C) 2009 John Wiley & Sons, Ltd.
机构:
Laboratory of Water Resources and Environment, Tianjin Normal University, Tianjin 300384, ChinaLaboratory of Water Resources and Environment, Tianjin Normal University, Tianjin 300384, China
Xue, Bing-Chun
Wang, Tao
论文数: 0引用数: 0
h-index: 0
机构:
Laboratory of Water Resources and Environment, Tianjin Normal University, Tianjin 300384, ChinaLaboratory of Water Resources and Environment, Tianjin Normal University, Tianjin 300384, China
Wang, Tao
Liu, Er-Bao
论文数: 0引用数: 0
h-index: 0
机构:
Laboratory of Water Resources and Environment, Tianjin Normal University, Tianjin 300384, ChinaLaboratory of Water Resources and Environment, Tianjin Normal University, Tianjin 300384, China
Liu, Er-Bao
Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis,
2006,
26
(05):
: 816
-
820
机构:
Tianjin Normal Univ, Lab Water Resources & Environm, Tianjin 300384, Peoples R ChinaTianjin Normal Univ, Lab Water Resources & Environm, Tianjin 300384, Peoples R China
Xue Bing-chun
Wang Tao
论文数: 0引用数: 0
h-index: 0
机构:
Tianjin Normal Univ, Lab Water Resources & Environm, Tianjin 300384, Peoples R ChinaTianjin Normal Univ, Lab Water Resources & Environm, Tianjin 300384, Peoples R China
Wang Tao
Liu Er-bao
论文数: 0引用数: 0
h-index: 0
机构:
Tianjin Normal Univ, Lab Water Resources & Environm, Tianjin 300384, Peoples R ChinaTianjin Normal Univ, Lab Water Resources & Environm, Tianjin 300384, Peoples R China