Effect of early activation of cochlear implant on electrode impedance in pediatric population

被引:15
|
作者
Alhabib, Salman F. [1 ]
Abdelsamad, Yassin [2 ]
Yousef, Medhat [1 ,3 ]
Alzhrani, Farid [1 ]
Hagr, Abdulrahman [1 ]
机构
[1] King Saud Univ, Coll Med, King Abdullah Ear Specialist Ctr KAESC, Riyadh, Saudi Arabia
[2] MED El GmbH, Res Dept, Riyadh, Saudi Arabia
[3] Menoufia Univ Hosp, Fac Med, Audiol Unit, Menoufia, Egypt
关键词
One-day activation; Electrode impedance; Fibrosis; Minimal invasive cochlear implantation technique; SAFETY;
D O I
10.1016/j.ijporl.2020.110543
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: To assess the evolution of electrode impedance after the early fitting of audio processors (activation after one-day) and classical fitting (activation after one-month) over an up-to-one year after cochlear implant (CI) surgery. Methods: A retrospective cohort study on Fifty-two CI recipients divided into two groups. The study group included 24 recipients (40 ears) who underwent early fitting, whereas the control group contained 28 recipients (40 ears) who underwent classical fitting. The electrode impedance was recorded during the surgery, switch-on session and at one, three, six, and twelve-months after the surgery. Results: In the study group, electrode impedance values obtained intraoperatively and at switch-on and one, three, six, and twelve-months were 4.89, 3.69, 6.52, 6.24, 6.05, and 5.81 K Omega, respectively, and only the switch-on and one-month values were significantly different (p < 0.0001). In the control group, electrode impedance values obtained intraoperatively and at switch-on and one, three, six, and twelve-months were 4.71, 7.19, 6.40, 6.05, and 5.73 K Omega, respectively. Thus, the electrode impedance value at switch-on was 52.65% (p < 0.001) greater than it intraoperatively. For both groups, the electrode impedance value at twelve-months was significantly higher than the respective intraoperative values (study group: 18.6% higher, P = 0.04; control group: 21.65% higher, P = 0.0001). Conclusion: Electrode impedance was significantly lower in the study group compared to the control group until one month after the surgery. However, the electrode impedance at twelve-months after the CI was similar in both groups.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Effect of age, electrode array, and time on cochlear implant impedances
    Velandia, Sandra
    Martinez, Diane
    Goncalves, Stefania
    Pena, Stefanie
    Bas, Esperanza
    Ein, Liliana
    Prentiss, Sandra
    Telischi, Fred
    Angeli, Simon
    Dinh, Christine T.
    COCHLEAR IMPLANTS INTERNATIONAL, 2020, 21 (06) : 344 - 352
  • [42] Intraoperative Impedance Measurements for the Evaluation of Perimodiolar Location of Cochlear Implant Electrode - Own Experience
    Stieler, O.
    Karlik, M.
    Szyfter, W.
    ACTA PHYSICA POLONICA A, 2010, 118 (01) : 161 - 163
  • [43] Incidence, Time Course, and Implications of Electrode Abnormalities in Pediatric Cochlear Implant Recipients
    Harris, Jennifer M.
    Neault, Marilyn W.
    O'Neill, Elizabeth E.
    Griffin, Amanda M.
    Kawai, Kosuke
    Kenna, Margaret A.
    Licameli, Greg R.
    EAR AND HEARING, 2021, 42 (02): : 334 - 342
  • [44] The Effect of Different Lubricants on Cochlear Implant Electrode Insertion Forces
    Kontorinis, Georgios
    Paasche, Gerrit
    Lenarz, Thomas
    Stoever, Timo
    OTOLOGY & NEUROTOLOGY, 2011, 32 (07) : 1050 - 1056
  • [45] Effect of Surgical Technique on Electrode Impedance After Cochlear Implantation
    Jia, Huan
    Venail, Frederic
    Piron, Jean-Pierre
    Batrel, Charlene
    Pelliccia, Pierfrancesco
    Artieres, Francoise
    Uziel, Alain
    Mondain, Michel
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2011, 120 (08): : 529 - 534
  • [46] Imaging evaluation of electrode placement and effect on electrode discrimination on different cochlear implant electrode arrays
    Ramos de Miguel, Angel
    Argudo, Andrea A.
    Borkoski Barreiro, Silvia A.
    Falcon Gonzalez, Juan Carlos
    Ramos Macias, Angel
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2018, 275 (06) : 1385 - 1394
  • [47] Imaging evaluation of electrode placement and effect on electrode discrimination on different cochlear implant electrode arrays
    Ángel Ramos de Miguel
    Andrea A. Argudo
    Silvia A. Borkoski Barreiro
    Juan Carlos Falcón González
    Angel Ramos Macías
    European Archives of Oto-Rhino-Laryngology, 2018, 275 : 1385 - 1394
  • [48] Evolution of impedance values in cochlear implant patients after early switch-on
    Wei, Jeff Jia-Fu
    Tung, Tao-Hsin
    Li, Lieber Po-Hung
    PLOS ONE, 2021, 16 (02):
  • [49] Speech production intelligibility of early implanted pediatric cochlear implant users
    Habib, Mirette G.
    Waltzman, Susan B.
    Tajudeen, Bobby
    Svirsky, Mario A.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2010, 74 (08) : 855 - 859
  • [50] A MULTIPLE-ELECTRODE COCHLEAR IMPLANT
    HOUSE, WF
    EDGERTON, BJ