Effect of early activation of cochlear implant on electrode impedance in pediatric population

被引:15
|
作者
Alhabib, Salman F. [1 ]
Abdelsamad, Yassin [2 ]
Yousef, Medhat [1 ,3 ]
Alzhrani, Farid [1 ]
Hagr, Abdulrahman [1 ]
机构
[1] King Saud Univ, Coll Med, King Abdullah Ear Specialist Ctr KAESC, Riyadh, Saudi Arabia
[2] MED El GmbH, Res Dept, Riyadh, Saudi Arabia
[3] Menoufia Univ Hosp, Fac Med, Audiol Unit, Menoufia, Egypt
关键词
One-day activation; Electrode impedance; Fibrosis; Minimal invasive cochlear implantation technique; SAFETY;
D O I
10.1016/j.ijporl.2020.110543
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: To assess the evolution of electrode impedance after the early fitting of audio processors (activation after one-day) and classical fitting (activation after one-month) over an up-to-one year after cochlear implant (CI) surgery. Methods: A retrospective cohort study on Fifty-two CI recipients divided into two groups. The study group included 24 recipients (40 ears) who underwent early fitting, whereas the control group contained 28 recipients (40 ears) who underwent classical fitting. The electrode impedance was recorded during the surgery, switch-on session and at one, three, six, and twelve-months after the surgery. Results: In the study group, electrode impedance values obtained intraoperatively and at switch-on and one, three, six, and twelve-months were 4.89, 3.69, 6.52, 6.24, 6.05, and 5.81 K Omega, respectively, and only the switch-on and one-month values were significantly different (p < 0.0001). In the control group, electrode impedance values obtained intraoperatively and at switch-on and one, three, six, and twelve-months were 4.71, 7.19, 6.40, 6.05, and 5.73 K Omega, respectively. Thus, the electrode impedance value at switch-on was 52.65% (p < 0.001) greater than it intraoperatively. For both groups, the electrode impedance value at twelve-months was significantly higher than the respective intraoperative values (study group: 18.6% higher, P = 0.04; control group: 21.65% higher, P = 0.0001). Conclusion: Electrode impedance was significantly lower in the study group compared to the control group until one month after the surgery. However, the electrode impedance at twelve-months after the CI was similar in both groups.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Cochlear Implantation: Long-Term Effect of Early Activation on Electrode Impedance
    Alahmadi, Asma
    Abdelsamad, Yassin
    Yousef, Medhat
    Almuhawas, Fida
    Hafez, Ahmed
    Alzhrani, Farid
    Hagr, Abdulrahman
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
  • [2] Cochlear Implant Failure in the Pediatric Population
    Ozer, Fulya
    Yavuz, Haluk
    Yilmaz, Ismail
    Ozluoglu, Levent N.
    JOURNAL OF AUDIOLOGY AND OTOLOGY, 2021, 25 (04): : 217 - 223
  • [3] Electrode Interaction in Pediatric Cochlear Implant Subjects
    Marc D. Eisen
    Kevin H. Franck
    Journal of the Association for Research in Otolaryngology, 2005, 6 : 160 - 170
  • [4] Electrode interaction in pediatric cochlear implant subjects
    Eisen, MD
    Franck, KH
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2005, 6 (02): : 160 - 170
  • [5] Ophthalmologic findings in a pediatric cochlear implant population
    Nikolaos, Ziakas
    Georgios, Psillas
    Angeliki, Chranioti
    Theodoros, Lalias
    Mattheos, Antoniadis
    Iosif, Vital
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (02) : 254 - 257
  • [6] OPHTHALMOLOGIC ABNORMALITIES IN THE PEDIATRIC COCHLEAR IMPLANT POPULATION
    SIATKOWSKI, RM
    FLYNN, JT
    HODGES, AV
    BALKANY, TJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (01) : 70 - 76
  • [7] Cochlear Implant Electrode Impedance as Potential Biomarker for Residual Hearing
    Wimmer, Wilhelm
    Sclabas, Luca
    Caversaccio, Marco
    Weder, Stefan
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [8] Intraoperative Cochlear Implant Reinsertion Effects Evaluated by Electrode Impedance
    Toner, Fearghal M.
    Sanli, Halit
    Hall, Andrew C.
    Birman, Catherine S.
    OTOLOGY & NEUROTOLOGY, 2020, 41 (06) : E695 - E699
  • [9] Cochlear implant electrode impedance subcomponents as biomarker for residual hearing
    Schraivogel, Stephan
    Aebischer, Philipp
    Weder, Stefan
    Caversaccio, Marco
    Wimmer, Wilhelm
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [10] Electrode Impedance Fluctuations and Sudden Decline in Cochlear-Implant Benefit
    Pitt, Cache
    Nagaraj, Naveen K.
    Salisbury, Anna