Improved Modulation Transfer Function evaluation method of a camera at any field point with a scanning tilted knife edge

被引:2
|
作者
Homassel, Etienne [1 ]
Barrat, Catherine [1 ]
Alves, Frederic [1 ]
Aubry, Gilles [1 ]
Arquetoux, Guillaume [1 ]
机构
[1] HGH Syst Infrarouges, Igny, France
关键词
Modulation Tranfer Function; Line Spread Function; Edge Spread function; Optical quality; Optics control and qualification; scanning MTF; MTF measurement Accuracy;
D O I
10.1117/12.2572852
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Modulating Transfer Function (MTF) has always been very important and useful for objectives quality definition and focal plane settings. This measurand provides the most relevant information on the optimized design and manufacturing of an optical system or the correct focus of a camera. MTF also gives out essential information on which defaults or aberrations appear on an optical objective, and so enables to diagnose potential design or manufacturing issues on a production line or R&D prototype. Test benches and algorithms have been defined and developed in order to satisfy the growing needs in optical objectives qualification as the latter become more and more critical in their accuracy and quality specification. Many methods are used to evaluate the Modulating Transfer Function. Slit imaging and scanning on a camera, MTF evaluation thanks to wavefront measurement or imaging fixed slanted knife edge on the detector of the camera. All these methods have pros and cons, some lack in resolution, accuracy or don't enable to compare simulated MTF curves with real measured data. These methods are firstly reminded in this paper. HGH has recently developed an improved and mixed version of a scanning technique used on a slanted knife edge giving a more accurate, ergonomic, high resolution and precise Line Spread Function (LSF) and one axis MTF measurement of a camera. A selected single pixel corresponding to a precise field point of the camera is scanned with sub pixelic resolution by the tilted knife edge thus enabling an optimized accuracy for LSF and MTF curves. The experimental protocol which requires a high-performance collimator, a scanning wheel device and a camera set up is detailed in this paper. Explained simulations are done to prove the under 1% accuracy of this method with regards to the different characteristics of the camera. All the parameters of this improved measurement technique are described and their effect criticized to give out all the result influence of these variables. These simulations and the algorithms used are then confronted to real measurements on a camera thanks to a mirror-based collimator and a scanning wheel device equipped with a slanted knife edge target.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Regularized slanted-edge method for measuring the modulation transfer function of imaging systems
    Xie, Xufen
    Fan, Hongda
    Wang, Anding
    Zou, Nianyu
    Zhang, Yuncui
    APPLIED OPTICS, 2018, 57 (22) : 6552 - 6558
  • [42] Measurement of the Modulation Transfer Function of Infrared Imaging System by Modified Slant Edge Method
    Li, Hang
    Yang, Changxiang
    Shao, Jianbing
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2016, 20 (03) : 381 - 388
  • [43] Evaluation method for modulation transfer function determination of digital image detector
    Chu, Chien-Hau
    Chen, Yen-Chun
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2015, : 233 - 234
  • [44] Effect of readout direction in the edge profile on the modulation transfer function of computed radiographic systems by use of the edge method
    Tanaka N.
    Morishita J.
    Tsuda N.
    Ohki M.
    Radiological Physics and Technology, 2013, 6 (2) : 474 - 479
  • [45] A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems
    Friedman, S. N.
    Cunningham, I. A.
    MEDICAL PHYSICS, 2008, 35 (06) : 2473 - 2484
  • [46] Edge-based modulation transfer function measurement method using a variable oversampling ratio
    Masaoka, Kenichiro
    OPTICS EXPRESS, 2021, 29 (23) : 37628 - 37638
  • [47] EVALUATION OF THE MODULATION TRANSFER-FUNCTION (MTF) OF A GAMMA-CAMERA USING THE DYNAMIC LINE PHANTOM
    GUIDARELLI, G
    ROSSI, A
    ADVERSI, I
    ABBATI, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (08): : 638 - 638
  • [48] Simple method for modulation transfer function determination of digital imaging detectors from edge images
    Buhr, E
    Günther-Kohfahl, S
    Neitzel, U
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 877 - 884
  • [49] Analysis of the Slanted-Edge Measurement Method for the Modulation Transfer Function of Remote Sensing Cameras
    Yu, Jian
    Zhang, Yu
    Qi, Biao
    Bai, Xiaotian
    Wu, Wei
    Liu, Hongxing
    APPLIED SCIENCES-BASEL, 2023, 13 (24):
  • [50] Assessment of uncertainty depending on various conditions in modulation transfer function calculation using the edge method
    Maruyama, Sho