Improved Modulation Transfer Function evaluation method of a camera at any field point with a scanning tilted knife edge

被引:2
|
作者
Homassel, Etienne [1 ]
Barrat, Catherine [1 ]
Alves, Frederic [1 ]
Aubry, Gilles [1 ]
Arquetoux, Guillaume [1 ]
机构
[1] HGH Syst Infrarouges, Igny, France
关键词
Modulation Tranfer Function; Line Spread Function; Edge Spread function; Optical quality; Optics control and qualification; scanning MTF; MTF measurement Accuracy;
D O I
10.1117/12.2572852
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Modulating Transfer Function (MTF) has always been very important and useful for objectives quality definition and focal plane settings. This measurand provides the most relevant information on the optimized design and manufacturing of an optical system or the correct focus of a camera. MTF also gives out essential information on which defaults or aberrations appear on an optical objective, and so enables to diagnose potential design or manufacturing issues on a production line or R&D prototype. Test benches and algorithms have been defined and developed in order to satisfy the growing needs in optical objectives qualification as the latter become more and more critical in their accuracy and quality specification. Many methods are used to evaluate the Modulating Transfer Function. Slit imaging and scanning on a camera, MTF evaluation thanks to wavefront measurement or imaging fixed slanted knife edge on the detector of the camera. All these methods have pros and cons, some lack in resolution, accuracy or don't enable to compare simulated MTF curves with real measured data. These methods are firstly reminded in this paper. HGH has recently developed an improved and mixed version of a scanning technique used on a slanted knife edge giving a more accurate, ergonomic, high resolution and precise Line Spread Function (LSF) and one axis MTF measurement of a camera. A selected single pixel corresponding to a precise field point of the camera is scanned with sub pixelic resolution by the tilted knife edge thus enabling an optimized accuracy for LSF and MTF curves. The experimental protocol which requires a high-performance collimator, a scanning wheel device and a camera set up is detailed in this paper. Explained simulations are done to prove the under 1% accuracy of this method with regards to the different characteristics of the camera. All the parameters of this improved measurement technique are described and their effect criticized to give out all the result influence of these variables. These simulations and the algorithms used are then confronted to real measurements on a camera thanks to a mirror-based collimator and a scanning wheel device equipped with a slanted knife edge target.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Non-uniform sampling knife-edge method for camera modulation transfer function measurement
    Duan, Yaxuan
    Xue, Xun
    Chen, Yongquan
    Tian, Liude
    Zhao, Jianke
    Gao, Limin
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS IV, 2016, 10023
  • [2] Comparison of tilted slit and tilted edge superresolution modulation transfer function techniques
    Olson, Jeffrey T.
    Espinola, Richard L.
    Jacobs, Eddie L.
    OPTICAL ENGINEERING, 2007, 46 (01)
  • [3] Modified slanted-edge method to measure the modulation transfer function of camera
    Zhang, Haosu
    Li, Chuang
    Duan, Yaxuan
    OPTIK, 2018, 157 : 635 - 643
  • [4] Modulation Transfer Function System for a Mid-infrared Lens by Knife- edge Scanning Technique
    Song, Se Yong
    Jo, Jae Heung
    Hong, Sung Mok
    Lee, Hoi Youn
    Lee, Yun-Woo
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2011, 22 (01) : 16 - 22
  • [6] A study of multi-angles knife-edge method applied to digital modulation transfer function measurement
    Fang, Yi-Chin
    Tsay, Ho-Lin
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2021, 27 (04): : 1429 - 1437
  • [7] Investigating the impact of ghost images on the accuracy of modulation transfer function measurement using knife-edge method
    Ryu, Dongok
    Kim, Seonghui
    Seong, Sehyun
    Seo, Hyunju
    Youk, Youngchun
    Kim, Goeun
    Kim, Shinwook
    Yoon, Jeeyeon
    Lee, Deog Gyu
    Heo, Haeng Pal
    UV/OPTICAL/IR SPACE TELESCOPES AND INSTRUMENTS: INNOVATIVE TECHNOLOGIES AND CONCEPTS XI, 2023, 12676
  • [8] A study of multi-angles knife-edge method applied to digital modulation transfer function measurement
    Yi-Chin Fang
    Ho-Lin Tsay
    Microsystem Technologies, 2021, 27 : 1429 - 1437
  • [9] Modulation transfer function measurement of image motion of aerial camera based on slanted-edge method
    Sun, Chongshang
    Wang, Qi
    Ding, Yalin
    Wang, Dejiang
    Meng, Fanhao
    Zhang, Lei
    Guangxue Xuebao/Acta Optica Sinica, 2014, 34 (12):
  • [10] An Improved Slanted-edge Method for Measuring Modulation Transfer Function Based on Edge-preserving Filter
    Nie, Saisai
    Ruan, Xiukai
    Cui, Guihua
    Lu, Weikuan
    FOURTEENTH INTERNATIONAL CONFERENCE ON GRAPHICS AND IMAGE PROCESSING, ICGIP 2022, 2022, 12705