Response of a nanoDot OSLD system in megavoltage photon beams

被引:9
|
作者
Hoshida, Kento [1 ]
Araki, Fujio [2 ]
Ohno, Takeshi [2 ]
Kobayashi, Ikuo [3 ]
机构
[1] Kumamoto Univ, Grad Sch Hlth Sci, 4-24-1 Kuhonji, Kumamoto 8620976, Japan
[2] Kumamoto Univ, Fac Life Sci, Dept Hlth Sci, 4-24-1 Kuhonji, Kumamoto 8620976, Japan
[3] Nagase Landauer Ltd, Block C22-1, Tsukuba, Ibaraki 3002686, Japan
关键词
nanoDot optically stimulated luminescence dosimeter (OSLD); Megavoltage photon beams; Energy response; Monte Carlo simulation; HIGH-ENERGY PHOTON; STIMULATED LUMINESCENT DETECTOR; ANGULAR-DEPENDENCE; DOSIMETRY SYSTEMS; DOSE-RESPONSE; ELECTRON; AL2O3-C; AUDITS;
D O I
10.1016/j.ejmp.2019.06.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to investigate the response of a nanoDot optically stimulated luminescence dosimeter (OSLD) system in megavoltage photon beams. Methods: The nanoDot response was compared with the ionization chamber measurements for 4-18-MV photons in a plastic water phantom. The response was also calculated by the Monte Carlo method. In addition, the perturbation correction factor, P-Q, in the nanoDot cavity was calculated according to the Burlin's cavity theory. The angular dependence of the nanoDot was evaluated using a spherical phantom. Results: The calculated and measured nanoDot responses at a 10-cm depth and 10 x 10-cm(2) field were in agreement within 1% for 4-18-MV. The response increased by 3% at a 20 x 20-cm(2) field for the lower energy of 4 MV; however, it was constant within +/- 1% for 6-18 MV. The response was in a range from 1.0 to 0.99 for mean photon energy of more than 1.0 MeV but it increased with less than the 1.0 MeV. P-Q for the nanoDot cavity was approximately constant at 0.96-0.97 for greater than and equal to 10 MV. The angular dependence decreased by 5% and 3% for 6 and 15 MV, respectively. Conclusions: The nanoDot was energy-independent in megavoltage photon beams.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [41] SURFACE DOSE FOR MEGAVOLTAGE PHOTON BEAMS OUTSIDE THE TREATMENT FIELD
    STARKSCHALL, G
    STGEORGE, FJ
    ZELLMER, DL
    MEDICAL PHYSICS, 1982, 9 (04) : 632 - 632
  • [42] Quality assurance of measured depth dose for megavoltage photon beams
    Thompson, AV
    Zhu, TC
    Bjärngard, BE
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 3108 - 3111
  • [43] Dependence of surface dose on atomic number in megavoltage photon beams
    Khan, Ahtesham Ullah
    Das, Indra J.
    MEDICAL PHYSICS, 2024, 51 (08) : 5746 - 5753
  • [44] Characterization of Head Scatter Off Axis in Megavoltage Photon Beams
    Novak, J.
    Zhu, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [45] Modeling the headscatter off-axis in megavoltage photon beams
    Finlay, J
    Li, J
    Zhu, T
    MEDICAL PHYSICS, 2005, 32 (06) : 1997 - 1997
  • [46] THE APPLICATION OF THE APPROXIMATION METHOD OF EQUIVALENT SQUARE FOR MEGAVOLTAGE PHOTON BEAMS
    OSMAN, GE
    TSUNG, PN
    JOURNAL OF MEDICINE, 1980, 11 (2-3) : 117 - 125
  • [47] Empirical modeling of the percent depth dose for megavoltage photon beams
    Li, Xiao-Jun
    Ye, Yan-Cheng
    Zhang, Yan-Shan
    Wu, Jia-Ming
    PLOS ONE, 2022, 17 (01):
  • [48] On few-view tomographic reconstruction with megavoltage photon beams
    Loose, S
    Leszczynski, KW
    MEDICAL PHYSICS, 2001, 28 (08) : 1679 - 1688
  • [49] Intermediate Megavoltage Photon Beams for Improved Lung Cancer Treatments
    Zhang, Ying
    Feng, Yuanming
    Ahmad, Munir
    Ming, Xin
    Zhou, Li
    Deng, Jun
    PLOS ONE, 2015, 10 (12):
  • [50] THE DOSIMETRIC EFFECTS OF ASYMMETRIC MEGAVOLTAGE BEAMS - RESPONSE
    TENHUNEN, M
    LAHTINEN, T
    RADIOTHERAPY AND ONCOLOGY, 1995, 35 (02) : 164 - 165