Prediction of response to cardiac resynchronization therapy using simple electrocardiographic and echocardiographic tools

被引:45
|
作者
Bonakdar, Hamid Reza [1 ]
Jorat, Mohammad Vahid [1 ]
Fazelifar, Amir Farjam [1 ]
Alizadeh, Abolfath [1 ]
Givtaj, Nozar [2 ]
Sameie, Niloofar [3 ]
Sadeghpour, Anita [3 ]
Haghjoo, Majid [1 ]
机构
[1] Iran Univ Med Sci, Dept Pacemaker & Electrophysiol, Rajaie Cardiovasc Med & Res Ctr, Tehran 1996911151, Iran
[2] Iran Univ Med Sci, Dept Res Lab, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[3] Iran Univ Med Sci, Dept Echocardiog, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
来源
EUROPACE | 2009年 / 11卷 / 10期
关键词
Cardiac resynchronization therapy; Heart failure; Response; Electrocardiography; Echocardiography; VENTRICULAR CONDUCTION DELAY; CONGESTIVE-HEART-FAILURE; QRS DURATION; DILATED CARDIOMYOPATHY; POSITIVE RESPONSE; DYSSYNCHRONY; DEFIBRILLATOR; IMPROVEMENT; IMPACT;
D O I
10.1093/europace/eup258
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To predict response to cardiac resynchronization therapy (CRT) in patients with heart failure (HF) and intraventricular conduction delay. The study population consisted of 82 consecutive HF patients with standard CRT indications. Patients were classified as responders, if they were alive without cardiac decompensation and experienced >= 15% decrease in left ventricular end-systolic volume. Sixty-eight percent of the enrolled patients responded to CRT. When compared with non-responders, responders had a wider baseline QRS width (P = 0.001), more marked QRS shortening (delta QRS) immediately after CRT (P = 0.001), and a better improvement in aortic velocity time integral (VTI) 24 h after CRT (P = 0.02). Moreover, there was a trend towards a greater baseline intraventricular dyssynchrony in the responder group (P = 0.07). By multivariable logistic regression, the baseline QRS width (OR: 0.95, 95% CI: 0.90-0.97, P = 0.001), delta QRS (OR: 1.038, 95% CI: 1.012-1.064, P = 0.003), and acute aortic VTI (OR: 0.81, 95% CI: 0.68-0.96, P = 0.017) emerged as independent predictors of response to CRT. Receiver operating characteristic curve analysis identified a QRS width > 145 ms, delta QRS > 20 ms, and aortic VTI > 14 cm to predict responders. A positive response to CRT was observed in 68% of the patients. Cardiac resynchronization therapy response is predictable using simple electrocardiographic and echocardiographic data.
引用
下载
收藏
页码:1330 / 1337
页数:8
相关论文
共 50 条
  • [41] Relationship of baseline electrocardiographic characteristics with the response to cardiac resynchronization therapy for heart failure
    Reynolds, MR
    Joventino, LP
    Josephson, ME
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (11): : 1513 - 1518
  • [42] Value of cardiac work estimation in the prediction of response to cardiac resynchronization therapy
    Galli, E.
    Leclercq, C.
    Hubert, A.
    Smiseth, O.
    Bernard, A.
    Samset, E.
    Hernandez, A.
    EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 106 - 107
  • [43] Noninvasive electrocardiographic assessment of ventricular activation and remodeling response to cardiac resynchronization therapy
    Jackson, Thomas
    Claridge, Simon
    Behar, Jonathan
    Yao, Cheng
    Elliott, Mark
    Mehta, Vishal
    Gould, Justin
    Sidhu, Baldeep
    Pereira, Helder
    Niederer, Steven
    Carr-White, Gerald
    Rinaldi, Christopher A.
    HEART RHYTHM O2, 2021, 2 (01): : 12 - 18
  • [44] Electrocardiographic Predictors of Response to Cardiac Resynchronization Therapy in Patients With Intraventricular Conduction Delay
    Takaya, Yoichi
    Noda, Takashi
    Nakajima, Ikutaro
    Yamada, Yuko
    Miyamoto, Koji
    Okamura, Hideo
    Satomi, Kazuhiro
    Aiba, Takeshi
    Kusano, Kengo F.
    Kanzaki, Hideaki
    Anzai, Toshihisa
    Ishihara, Masaharu
    Yasuda, Satoshi
    Ogawa, Hisao
    Kamakura, Shiro
    Shimizu, Wataru
    CIRCULATION JOURNAL, 2014, 78 (01) : 71 - 77
  • [45] Newer Echocardiographic Techniques in Cardiac Resynchronization Therapy
    Gorcsan, John, III
    Tayal, Bhupendar
    HEART FAILURE CLINICS, 2017, 13 (01) : 53 - +
  • [46] Assessment of response criteria to cardiac resynchronization therapy (CRT) and prediction of response
    Aaronaes, Marit
    Aakhus, Svend
    Aass, Halfdan
    Moum, Torbjorn
    Wergeland, Ragnhild
    Gullestad, Lars
    Kongsgard, Erik
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2010, 44 (06) : 337 - 345
  • [47] A Comparison of Cardiac Resynchronization Therapy Optimization Using QuickOpt® and Echocardiographic Parameters
    Hansalia, Riple
    Duvall, William
    Buckley, Samantha
    Tilton, Bryan
    Poole, Kari
    Lee, Li-Yin
    Fischer, Avi
    JOURNAL OF CARDIAC FAILURE, 2009, 15 (06) : S59 - S59
  • [48] Effect of sear site on acute electrocardiographic and echocardiographic parameters in ischemic patients undergoing cardiac resynchronization therapy
    Bedi, Maninder S.
    Suffoletto, Matthew
    Tanabe, Masaki
    Gorcsan, John
    Saba, Samir
    JOURNAL OF CARDIAC FAILURE, 2006, 12 (06) : S61 - S61
  • [49] Long-Term Echocardiographic Response to Cardiac Resynchronization Therapy in Initial Nonresponders
    Burns, Kevin V.
    Gage, Ryan M.
    Curtin, Antonia E.
    Bank, Alan J.
    JACC-HEART FAILURE, 2015, 3 (12) : 990 - 997
  • [50] Optimization by QuickOpt™ improves Echocardiographic Response to Cardiac Resynchronization Therapy: A Case Report
    Yasuda, Yu
    Okada, Taiji
    Endo, Akihiro
    Tanabe, Kazuaki
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (10) : S201 - S201