Behavior and analysis of unsymmetrical double barrel precast concrete box culverts with posttensioning bars

被引:4
|
作者
Wu, Xiangguo [1 ,2 ]
Kang, Thomas H. -K. [3 ,4 ]
Xia, Xinlei [5 ,6 ]
Chen, Xiao-Kai [5 ]
Hwang, Hyeon-Jong [7 ,8 ]
Zhou, Ruihua [9 ]
机构
[1] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Harbin 150090, Heilongjiang, Peoples R China
[3] Seoul Natl Univ, Dept Architecture & Architectural Engn, Seoul 08826, South Korea
[4] Seoul Natl Univ, Engn Educ Innovat Ctr, Seoul 08826, South Korea
[5] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[6] Shanghai Municipal Engn Design Inst Grp Co Ltd, Shanghai 200092, Peoples R China
[7] Hunan Univ, Coll Civil Engn, Hunan Prov Key Lab Damage Diag Engn Struct, Changsha 410082, Hunan, Peoples R China
[8] Seoul Natl Univ, Engn Res Inst, Seoul, South Korea
[9] Harbin Songjiang Concrete Components Co Ltd, Harbin 150059, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
culvert; elastic foundation beam method; interface joint; precast concrete; reaction method; stress distribution; waterproof;
D O I
10.1002/suco.201800208
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study focused on the structural behavior of double barrel precast concrete (PC) box culverts where the width of each barrel may vary from that of the other. In lieu of using the elastic foundation beam method, current design codes specify use of reaction method to evaluate the internal force distribution between the two culvert segments. On the basis of a parametric study, a modification of reaction method was proposed to consider the effects of foundation stiffness and structural configuration. The proposed method predicted well the structural behavior of the structure on ground. Further, the structural integrity of each PC segment and between the segments is significantly affected by the sectional layout of posttensioning bars because the cross-sectional area of the culvert is large. Significant stress concentration and nonuniform stress distribution also affects waterproofing performance of elastic sealing rubber strips at joint interfaces. To evaluate this, numerical analysis was performed with various sectional layouts of posttensioning bars. The distribution and average value of stresses were significantly affected by the posttensioning bar layout. Results of this study can be used as reference for design methods associated with double barrel PC box culverts where width of each barrel may vary from that of the other.
引用
收藏
页码:1438 / 1450
页数:13
相关论文
共 50 条
  • [21] Structural Behavior of Precast Reinforced Concrete Shear Walls with Large-Diameter Bars
    Chen, Xin
    Liu, Ming
    Biondini, Fabio
    Rosati, Gianpaolo
    ACI STRUCTURAL JOURNAL, 2019, 116 (05) : 77 - 86
  • [22] Flexural Behavior of Precast Concrete Slab Connections using Loop Steel Bars and Mortar
    Nguyen, Quang-Thinh
    Maki, Takeshi
    Mutsuyoshi, Hiroshi
    Ishihara, Yosuke
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2023, 21 (06) : 436 - 449
  • [23] Experimental Investigations on the Seismic Behavior of Precast Concrete Columns with Novel Box Connections
    Zhang, Xizhi
    Xu, Shengbo
    Zhang, Shaohua
    Xu, Gaodong
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2020, 14 (02)
  • [24] Two-Way Shear Strength of GFRP-Reinforced Precast Concrete Box Culverts under Vertical Concentrated Loading
    Elnady, Ahmed
    Mousa, Salaheldin
    Benmokrane, Brahim
    Journal of Composites for Construction, 2025, 29 (01)
  • [25] Flexural Behavior of Precast Concrete Segmental Box-Girders with Dry Joints
    Chai, Shun
    Guo, Tong
    Chen, Zheheng
    Yang, Jun
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [26] Numerical analysis on seismic behavior of precast concrete frames
    Zhang, Xuan
    Zou, Yun
    Kong, Jie
    Bi, Tuan-Wei
    Zhao, Tao-Gan
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MECHANICS AND MECHATRONICS (ICMM 2015), 2016, : 1171 - 1178
  • [27] Lateral hysteretic behavior of precast concrete shear walls with unjointed vertical distribution bars and opening
    Cai, Qi
    Song, Xiaobin
    Xiao, Xuwen
    Gu, Xianglin
    ENGINEERING STRUCTURES, 2024, 305
  • [28] Design, Construction, Testing, and Behavior of Driven Precast Concrete Piles Reinforced with GFRP Bars and Spirals
    Benmokrane, Brahim
    Mohamed, Hamdy M.
    Mousa, Salaheldin
    Elsafty, Adel
    Nolan, Steven
    JOURNAL OF BRIDGE ENGINEERING, 2021, 26 (08)
  • [29] Cyclic behavior of precast segmental concrete bridge columns with high performance or conventional steel reinforcing bars as energy dissipation bars
    Ou, Yu-Chen
    Tsai, Mu-Sen
    Chang, Kuo-Chun
    Lee, George C.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (11): : 1181 - 1198
  • [30] Influence of intensity & eccentricity of posttensioning force and concrete strength on shear behavior of epoxied joints in segmental box girder bridges
    Ahmed, Ghafur H.
    Aziz, Omar Q.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 197 : 117 - 129