Design, Construction, Testing, and Behavior of Driven Precast Concrete Piles Reinforced with GFRP Bars and Spirals

被引:14
|
作者
Benmokrane, Brahim [1 ,2 ]
Mohamed, Hamdy M. [3 ]
Mousa, Salaheldin [3 ,4 ]
Elsafty, Adel [5 ]
Nolan, Steven [6 ]
机构
[1] Univ Sherbrooke, Tier 1 Canada Res Chair Adv Composite Mat Civil S, Dept Civil & Bldg Engn, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, NSERC Res Chair Innovat FRP Reinforcement Concret, Dept Civil & Bldg Engn, Sherbrooke, PQ J1K 2R1, Canada
[3] Univ Sherbrooke, Dept Civil & Bldg Engn, Sherbrooke, PQ J1K 2R1, Canada
[4] Benha Univ, Fac Engn Shoubra, Banha, Egypt
[5] UNF, Civil Engn, Coll Comp Engn & Construct, Jacksonville, FL 32224 USA
[6] Florida Dept Transportat FDOT, Adv Mat Struct Durabil & Resiliency, State Structures Design Off, Tallahassee, FL 32399 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Precast; Concrete; Piles; Driving test; GFRP bars and spirals; Lab and field tests; Concrete bridge; Stress; Energy; Design; COLUMNS;
D O I
10.1061/(ASCE)BE.1943-5592.0001755
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Marine, coastal structures, and bridges deteriorate prematurely due to corrosion. Numerous failures have occurred in substructure members of these structures, such as piles, leading to very high repair and replacement costs. Problems related to corrosion could be resolved through the use of noncorroding materials such as fiber-reinforced polymer (FRP) bars. This paper presents the design, construction details, driving test procedures, and results of the field dynamic driving testing of precast glass-FRP (GFRP) reinforced concrete (RC) piles, as well as laboratory test results, to determine the piles flexural strength. Four piles were longitudinally and transversally reinforced with GFRP bars, spirals, and ties. Two of the piles were 6.0 m (approximately 20 ft) long, were fabricated, instrumented, and were laboratory tested for flexural strength. The other two piles were 18.0 m (approximately 60 ft) in length, were field installed and dynamically monitored. They were driven and monitored at the Arthur Drive Bridge project site in Lynn Haven, Panama City, Florida. Pile driving and testing were performed with a Vulcan 512 single-acting air hammer. The embedded data collectors (EDCs) were used to monitor the piles during driving operations. Field driving observations and results indicate that no pile damage occurred during installation. GFRP spirals successfully confined the concrete core of the piles and prevented cover spalling during driving. The maximum tensile and compressive stresses measured in the piles were well within the allowable design limits. Design aids and recommendations for good driving practices for GFRP-RC piles were presented. The promising results presented for the driven precast GFRP-RC piles represent a further step toward field application.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Structural behavior of jointed precast concrete beams reinforced with GFRP bars
    Eldaleel, Taha
    Elgabbas, Fareed
    Abdelaziz, Ahmed F.
    Morsy, Khalid M.
    ENGINEERING STRUCTURES, 2024, 310
  • [2] GFRP composite bars for splicing prestressed precast concrete piles: Design and experimental investigation
    Farhangdoust, Saman
    Mehrabi, Armin
    Nolan, Steven
    ENGINEERING STRUCTURES, 2022, 272
  • [3] Behavior of axially loaded low strength concrete columns reinforced with GFRP bars and spirals
    El-Gamal, Sherif
    AlShareedah, Othman
    ENGINEERING STRUCTURES, 2020, 216 (216)
  • [4] Development and testing of new precast concrete tunnel segments reinforced with GFRP bars and ties
    Hosseini, S. M.
    Mousa, S.
    Mohamed, H. M.
    Benmokrane, B.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 1453 - 1458
  • [5] Development and testing of new precast concrete tunnel segments reinforced with GFRP bars and ties
    Hosseini, S. M.
    Mousa, S.
    Mohamed, H. M.
    Benmokrane, B.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 505 - 506
  • [6] Axial Capacity of Circular Concrete Columns Reinforced with GFRP Bars and Spirals
    Afifi, Mohammad Z.
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (01)
  • [7] Investigation of Circular Hollow Concrete Columns Reinforced with GFRP Bars and Spirals
    Ahmad, Afaq
    Bahrami, Alireza
    Alajarmeh, Omar
    Chairman, Nida
    Yaqub, Muhammad
    BUILDINGS, 2023, 13 (04)
  • [8] Compressive behavior of axially loaded circular hollow concrete columns reinforced with GFRP bars and spirals
    AlAjarmeh, O. S.
    Manalo, A. C.
    Benmokrane, B.
    Karunasena, W.
    Mendis, P.
    Nguyen, K. T. Q.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 194 : 12 - 23
  • [9] Numerical evaluation of axial compressive behavior of hollow concrete columns reinforced with GFRP bars and spirals
    Tahir, Muhammad
    Karam, Muhammad Shoaib
    Hassam, Muhammad
    Umer, Muhammad
    Hameed, Rashid
    STRUCTURAL CONCRETE, 2024, 25 (01) : 566 - 582
  • [10] Behavior of concrete beams reinforced with GFRP BARS
    Kalpana, V. G.
    Subramanian, K.
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2011, 30 (23) : 1915 - 1922