Design, Construction, Testing, and Behavior of Driven Precast Concrete Piles Reinforced with GFRP Bars and Spirals

被引:14
|
作者
Benmokrane, Brahim [1 ,2 ]
Mohamed, Hamdy M. [3 ]
Mousa, Salaheldin [3 ,4 ]
Elsafty, Adel [5 ]
Nolan, Steven [6 ]
机构
[1] Univ Sherbrooke, Tier 1 Canada Res Chair Adv Composite Mat Civil S, Dept Civil & Bldg Engn, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, NSERC Res Chair Innovat FRP Reinforcement Concret, Dept Civil & Bldg Engn, Sherbrooke, PQ J1K 2R1, Canada
[3] Univ Sherbrooke, Dept Civil & Bldg Engn, Sherbrooke, PQ J1K 2R1, Canada
[4] Benha Univ, Fac Engn Shoubra, Banha, Egypt
[5] UNF, Civil Engn, Coll Comp Engn & Construct, Jacksonville, FL 32224 USA
[6] Florida Dept Transportat FDOT, Adv Mat Struct Durabil & Resiliency, State Structures Design Off, Tallahassee, FL 32399 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Precast; Concrete; Piles; Driving test; GFRP bars and spirals; Lab and field tests; Concrete bridge; Stress; Energy; Design; COLUMNS;
D O I
10.1061/(ASCE)BE.1943-5592.0001755
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Marine, coastal structures, and bridges deteriorate prematurely due to corrosion. Numerous failures have occurred in substructure members of these structures, such as piles, leading to very high repair and replacement costs. Problems related to corrosion could be resolved through the use of noncorroding materials such as fiber-reinforced polymer (FRP) bars. This paper presents the design, construction details, driving test procedures, and results of the field dynamic driving testing of precast glass-FRP (GFRP) reinforced concrete (RC) piles, as well as laboratory test results, to determine the piles flexural strength. Four piles were longitudinally and transversally reinforced with GFRP bars, spirals, and ties. Two of the piles were 6.0 m (approximately 20 ft) long, were fabricated, instrumented, and were laboratory tested for flexural strength. The other two piles were 18.0 m (approximately 60 ft) in length, were field installed and dynamically monitored. They were driven and monitored at the Arthur Drive Bridge project site in Lynn Haven, Panama City, Florida. Pile driving and testing were performed with a Vulcan 512 single-acting air hammer. The embedded data collectors (EDCs) were used to monitor the piles during driving operations. Field driving observations and results indicate that no pile damage occurred during installation. GFRP spirals successfully confined the concrete core of the piles and prevented cover spalling during driving. The maximum tensile and compressive stresses measured in the piles were well within the allowable design limits. Design aids and recommendations for good driving practices for GFRP-RC piles were presented. The promising results presented for the driven precast GFRP-RC piles represent a further step toward field application.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Experimental investigation of concentrically and eccentrically loaded circular hollow concrete columns reinforced with GFRP bars and spirals
    Gouda, Mohammed Gamal
    Mohamed, Hamdy M.
    Manalo, Allan C.
    Benmokrane, Brahim
    ENGINEERING STRUCTURES, 2023, 277
  • [32] INVESTIGATION OF DESIGN METHODS FOR CONCRETE BRIDGE DECK REINFORCED WITH GFRP BARS
    Li, Chunhong
    Yu, Zheng
    Wei, Demin
    INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE PERFORMANCE OF BRIDGES AND STRUCTURES, 2010, : 463 - 467
  • [33] Flexural performances of prestressed high strength concrete piles reinforced with hybrid GFRP and steel bars
    Wu, Ping
    Guo, Yang
    Zhu, Dayong
    Jin, Weiliang
    Zhang, Zhenhua
    Liang, Rongzhu
    MARINE GEORESOURCES & GEOTECHNOLOGY, 2020, 38 (05) : 518 - 526
  • [34] Design for shear strength of concrete beams longitudinally reinforced with GFRP bars
    Thomas, Job
    Ramadass, S.
    STRUCTURAL ENGINEERING AND MECHANICS, 2015, 53 (01) : 41 - 55
  • [35] Strength and Axial Behavior of Circular Concrete Columns Reinforced with CFRP Bars and Spirals
    Afifi, Mohammad Z.
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (02)
  • [36] Circular Concrete Columns and Beams Reinforced with GFRP Bars and Spirals under Axial, Eccentric, and Flexural Loading
    Elchalakani, Mohamed
    Dong, Minhao
    Karrech, Ali
    Ali, Mohamed Sadakkathulla Mohamed
    Huo, Jing-Si
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2020, 24 (03)
  • [37] Fire-resistance design on concrete structures reinforced with GFRP bars
    Zhou, Chang-Dong
    Lu, Xi-Lin
    Jin, Ye
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2009, 12 (01): : 32 - 35
  • [38] The Design of Concrete Beams Reinforced with GFRP Bars Based on Crack Width
    Tu, Jianwei
    Zhao, Quan
    Gao, Kui
    MATERIALS, 2022, 15 (18)
  • [39] Bridge foundations of precast reinforced concrete piles
    2017, Associated Cement Companies Ltd. (91):
  • [40] Elastic and Inelastic Behavior of Precast Concrete Piles and Cast-in-Shell Steel Piles in Reinforced Concrete Caps
    Kidwell, Taylor B.
    Kerley, Rebekah F.
    Henderson, R. Craig
    Huff, Tim
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2018, 23 (02)