Reliability of direct varicella zoster virus loop-mediated isothermal amplification method for rapid diagnosis of breakthrough varicella

被引:3
|
作者
Higashimoto, Yuki [1 ]
Kawamura, Yoshiki [2 ]
Kuboshiki, Ayumi [1 ]
Hattori, Fumihiko [2 ]
Miura, Hiroki [2 ]
Nishimura, Naoko [3 ]
Ozaki, Takao [3 ]
Ihira, Masaru [4 ]
Yoshikawa, Tetsushi [2 ]
Itakura, Naoko
Kawai, Susumu
Kozawa, Toru
Maeda, Toshiko
Onishi, Masazumi
Osawa, Masahiko
Suga, Sadao
Sugiyama, Yukari
Tanaka, Hiroshi
Uchikawa, Koji
Yamaguchi, Nobuyuki
机构
[1] Fujita Hlth Univ, Fac Med Technol, Sch Med Sci, Toyoake, Aichi, Japan
[2] Fujita Hlth Univ, Sch Med, Dept Pediat, Toyoake, Aichi 4701192, Japan
[3] Konan Kosei Hosp, Dept Pediat, 137 Ohmatsubara,Takaya Cho, Konan, Aichi, Japan
[4] Fujita Hlth Univ, Fac Clin Engn, Sch Med Sci, Toyoake, Aichi, Japan
关键词
Varicella zoster virus; Breakthrough varicella; Loop-mediated isothermal amplification; Laboratory diagnosis; HERPES-SIMPLEX-VIRUS; VACCINE; DNA; INFECTION; CHILDREN; JAPAN; IMMUNIZATION; IMMUNITY; STRAIN;
D O I
10.1016/j.jcv.2019.07.009
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Since patients with breakthrough varicella (BV) have mild symptoms, clinical diagnosis is difficult. In high vaccine coverage area, as BV occurs sporadically, point of care test is required for controlling varicella outbreak. In this study, the reliability of varicella zoster virus (VZV)-loop mediated isothermal amplification (LAMP) was evaluated for the rapid diagnosis of BV. Study design: A total of 328 swab samples collected from patients with suspected varicella were analyzed. For the laboratory diagnosis of varicella, VZV real-time PCR was carried out using DNA extracted from swab samples. Swab samples without DNA extraction were used for VZV-LAMP(direct-LAMP). Results: VZV infection was diagnosed by real-time PCR in 285 cases, including 105 natural varicella cases and 180 BV cases. VZV DNA was detected in 250 (87.8%) of the 285 cases by direct-LAMP. The presence and duration of fever, number of skin eruptions, and VZV DNA load were significantly lower in BV than natural varicella. The sensitivity of direct-LAMP for the diagnosis of varicella and BV was 93.3% and 84.4%, respectively. Conclusions: Direct LAMP was considered to be useful for rapid diagnosis of BV as it has several advantages such as low cost, ease and rapidity, as compared to real time PCR.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [41] A modified loop-mediated isothermal amplification method for diagnosis of Cryptococcal meningitis
    Chen, M.
    Li, L.
    Zhou, Z.
    Li, L.
    Zhang, Z.
    Meng, Y.
    Boekhout, T.
    Liao, W.
    Pan, A.
    MYCOSES, 2014, 57 : 51 - 52
  • [42] Rapid diagnosis of human herpesvirus 6 infection by a novel DNA amplification method, loop-mediated isothermal amplification
    Ihira, M
    Yoshikawa, T
    Enomoto, Y
    Akimoto, S
    Ohashi, M
    Suga, S
    Nishimura, N
    Ozaki, T
    Nishiyama, Y
    Notomi, T
    Ohta, Y
    Asano, Y
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) : 140 - 145
  • [43] Development of a loop-mediated isothermal amplification method to detect Zika virus
    Escalante-Maldonado, O.
    Garcia, P.
    Cabezas, C.
    Cabezas, C.
    Gavilan, R.
    Yamazaki, W.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2019, 79 : 34 - 34
  • [44] Rapid detection of squash leaf curl virus by loop-mediated isothermal amplification
    Kuan, Cheng-Ping
    Wu, Min-Tze
    Lu, Yi-Lin
    Huang, Hung-Chang
    JOURNAL OF VIROLOGICAL METHODS, 2010, 169 (01) : 61 - 65
  • [45] Rapid detection of infectious laryngotracheitis virus isolates by loop-mediated isothermal amplification
    Xie, Qing-mei
    Ji, Jun
    Pickens, Tristan Tyler
    Du, Li-qin
    Cao, Yong-chang
    Li, Hong-mei
    Wang, Lin-guo
    Ma, Jing-yun
    Bi, Ying-zuo
    JOURNAL OF VIROLOGICAL METHODS, 2010, 165 (01) : 71 - 75
  • [46] Molecular epidemiology and a loop-mediated isothermal amplification method for diagnosis of infection with rabies virus in Zambia
    Muleya, Walter
    Namangala, Boniface
    Mweene, Aaron
    Zulu, Luke
    Fandamu, Paul
    Banda, Douglas
    Kimura, Takashi
    Sawa, Hirofumi
    Ishii, Akihiro
    VIRUS RESEARCH, 2012, 163 (01) : 160 - 168
  • [47] Loop-mediated isothermal amplification for the rapid detection of Salmonella
    Hara-Kudo, Y
    Yoshino, M
    Kojima, T
    Ikedo, M
    FEMS MICROBIOLOGY LETTERS, 2005, 253 (01) : 155 - 161
  • [48] Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Hepatitis C virus
    Kargar, Mohammad
    Askari, Ahzam
    Doosti, Abbas
    Ghorbani-Dalini, Sadegh
    INDIAN JOURNAL OF VIROLOGY, 2012, 23 (01): : 18 - 23
  • [49] Rapid detection of milk vetch dwarf virus by loop-mediated isothermal amplification
    Zhang, Jun
    Li, Xiaowei
    Li, Wei
    Zhang, Jing
    Xiao, Zhixin
    Zhou, Zhicheng
    Liu, Tianbo
    Li, Ying
    Wang, Fenglong
    Zhang, Songbai
    Yang, Jinguang
    JOURNAL OF VIROLOGICAL METHODS, 2018, 261 : 147 - 152
  • [50] Evaluation of Loop-mediated Isothermal Amplification Assay for Rapid Diagnosis of Acanthamoeba Keratitis
    Mewara, Abhishek
    Khurana, Sumeeta
    Yoonus, Shakila
    Megha, Kirti
    Tanwar, Parveen
    Gupta, Amit
    Sehgal, Rakesh
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2017, 35 (01) : 90 - 94