Reliability of direct varicella zoster virus loop-mediated isothermal amplification method for rapid diagnosis of breakthrough varicella

被引:3
|
作者
Higashimoto, Yuki [1 ]
Kawamura, Yoshiki [2 ]
Kuboshiki, Ayumi [1 ]
Hattori, Fumihiko [2 ]
Miura, Hiroki [2 ]
Nishimura, Naoko [3 ]
Ozaki, Takao [3 ]
Ihira, Masaru [4 ]
Yoshikawa, Tetsushi [2 ]
Itakura, Naoko
Kawai, Susumu
Kozawa, Toru
Maeda, Toshiko
Onishi, Masazumi
Osawa, Masahiko
Suga, Sadao
Sugiyama, Yukari
Tanaka, Hiroshi
Uchikawa, Koji
Yamaguchi, Nobuyuki
机构
[1] Fujita Hlth Univ, Fac Med Technol, Sch Med Sci, Toyoake, Aichi, Japan
[2] Fujita Hlth Univ, Sch Med, Dept Pediat, Toyoake, Aichi 4701192, Japan
[3] Konan Kosei Hosp, Dept Pediat, 137 Ohmatsubara,Takaya Cho, Konan, Aichi, Japan
[4] Fujita Hlth Univ, Fac Clin Engn, Sch Med Sci, Toyoake, Aichi, Japan
关键词
Varicella zoster virus; Breakthrough varicella; Loop-mediated isothermal amplification; Laboratory diagnosis; HERPES-SIMPLEX-VIRUS; VACCINE; DNA; INFECTION; CHILDREN; JAPAN; IMMUNIZATION; IMMUNITY; STRAIN;
D O I
10.1016/j.jcv.2019.07.009
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Since patients with breakthrough varicella (BV) have mild symptoms, clinical diagnosis is difficult. In high vaccine coverage area, as BV occurs sporadically, point of care test is required for controlling varicella outbreak. In this study, the reliability of varicella zoster virus (VZV)-loop mediated isothermal amplification (LAMP) was evaluated for the rapid diagnosis of BV. Study design: A total of 328 swab samples collected from patients with suspected varicella were analyzed. For the laboratory diagnosis of varicella, VZV real-time PCR was carried out using DNA extracted from swab samples. Swab samples without DNA extraction were used for VZV-LAMP(direct-LAMP). Results: VZV infection was diagnosed by real-time PCR in 285 cases, including 105 natural varicella cases and 180 BV cases. VZV DNA was detected in 250 (87.8%) of the 285 cases by direct-LAMP. The presence and duration of fever, number of skin eruptions, and VZV DNA load were significantly lower in BV than natural varicella. The sensitivity of direct-LAMP for the diagnosis of varicella and BV was 93.3% and 84.4%, respectively. Conclusions: Direct LAMP was considered to be useful for rapid diagnosis of BV as it has several advantages such as low cost, ease and rapidity, as compared to real time PCR.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [21] Development of a loop-mediated isothermal amplification for rapid detection of orf virus
    Tsai, Su-Ming
    Chan, Kun-Wei
    Hsu, Wei-Li
    Chang, Tien-Jye
    Wong, Min-Liang
    Wang, Chi-Young
    JOURNAL OF VIROLOGICAL METHODS, 2009, 157 (02) : 200 - 204
  • [22] Development of loop-mediated isothermal amplification method for diagnosis of bovine leukemia virus infection
    Komiyama, Chiho
    Suzuki, Kazuhiko
    Miura, Yasuo
    Sentsui, Hiroshi
    JOURNAL OF VIROLOGICAL METHODS, 2009, 157 (02) : 175 - 179
  • [23] Loop-mediated isothermal amplification for rapid detection of Chinese sacbrood virus
    Ma, Mingxiao
    Ma, Chen
    Li, Mng
    Wang, Shuquan
    Yang, Song
    Wang, Shude
    JOURNAL OF VIROLOGICAL METHODS, 2011, 176 (1-2) : 115 - 119
  • [24] Loop-mediated isothermal amplification assay for rapid and sensitive diagnosis of tuberculosis
    Kumar, Parveen
    Pandya, Deepal
    Singh, Niti
    Behera, Digambar
    Aggarwal, Praveen
    Singh, Sarman
    JOURNAL OF INFECTION, 2014, 69 (06) : 607 - 615
  • [25] Loop-Mediated Isothermal Amplification for Rapid and Reliable Diagnosis of Tuberculous Meningitis
    Nagdev, Khushboo J.
    Kashyap, Rajpal S.
    Parida, Manmohan M.
    Kapgate, Rajkumar C.
    Purohit, Hemant J.
    Taori, Girdhar M.
    Daginawala, Hatim F.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (05) : 1861 - 1865
  • [26] Development of a loop-mediated isothermal amplification for rapid diagnosis of Aphelenchoides ritzemabosi
    Wang, Dong-Wei
    Xu, Chun-Ling
    Bai, Zong-Shi
    Li, Jun-Yi
    Han, Yu-Chun
    Zhao, Li-Rong
    Xie, Hui
    EUROPEAN JOURNAL OF PLANT PATHOLOGY, 2019, 155 (01) : 173 - 179
  • [27] Loop-Mediated Isothermal Amplification for Rapid Diagnosis of Tubercular Uveitis Reply
    Sharma, Kusum
    Sharma, Aman
    Gupta, Amod
    JAMA OPHTHALMOLOGY, 2015, 133 (02) : 226 - 226
  • [28] Rapid and sensitive diagnosis of Acanthamoeba keratitis by loop-mediated isothermal amplification
    Ge, Z.
    Qing, Y.
    Zicheng, S.
    Shiying, S.
    CLINICAL MICROBIOLOGY AND INFECTION, 2013, 19 (11) : 1042 - 1048
  • [29] Sensitive and rapid detection of Zika virus by loop-mediated isothermal amplification
    Jiangtao Zhao
    Ruo Feng
    Virus Genes, 2019, 55 : 43 - 50
  • [30] Sensitive and rapid detection of Zika virus by loop-mediated isothermal amplification
    Zhao, Jiangtao
    Feng, Ruo
    VIRUS GENES, 2019, 55 (01) : 43 - 50