Use of an x-ray beam-limiting cone to improve radiographic quality in diagnosis of traumatic reticuloperitonitis

被引:0
|
作者
Pravettoni, Davide [1 ]
Zani, Davide D. [2 ]
Biggi, Marianna [2 ]
Morandi, Nicola [1 ]
Di Giancamillo, Mauro [2 ]
Bertagnoli, Alberto [1 ]
Belloli, Angelo G. [1 ]
机构
[1] Univ Milan, Clin Ruminanti & Suino, Osped Vet Grandi Anim, Dipartimento Sci Clin Vet, I-26900 Lodi, Italy
[2] Sez Radiol Vet Clin & Sperimentale, I-26900 Lodi, Italy
来源
DEUTSCHE TIERARZTLICHE WOCHENSCHRIFT | 2009年 / 116卷 / 12期
关键词
traumatic reticuloperitonitis; cow; radiography; x-ray beam-limiting cone; diagnostic imaging; COWS; CATTLE;
D O I
10.2376/0341-6593-116-429
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
To evaluate the quality and the diagnostic relevance of the radiographs of the reticular area obtained using an x-ray beam-limiting cone (LC), both conventional and LC images were analysed in 12 cows affected by traumatic reticuloperitonitis (TRP). The improvement in resolution, definition and contrast of the LC images and a clinical assessment of the diagnostic relevance of the procedure were scored. The use of LC improved the quality of the radiographs in 10 cases (83%) thanks to an improvement in the resolution (67%), definition (58%) and contrast (83%). The procedure was diagnostically relevant in 5 cases (42%), facilitating the detection of details not clearly visualised by previous conventional survey radiographs: a very thin foreign body responsible of TRF, a mass in the ventro-caudal contour of the reticulum, the exact position of the foreign bodies. A consistency test for the x-rays was performed in a clinically healthy cow to confirm the improvement in the radiographic quality determined by the procedure. Although conventional imaging is often sufficient to confirm diagnosis of TRP, the use of the LC improves the quality of reticular radiographs and in several cases can be fundamental for the identification of a thin foreign body or a lesion.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [41] Cone beam x-ray luminescence computed tomography: A feasibility study
    Chen, Dongmei
    Zhu, Shouping
    Yi, Huangjian
    Zhang, Xianghan
    Chen, Duofang
    Liang, Jimin
    Tian, Jie
    MEDICAL PHYSICS, 2013, 40 (03)
  • [42] Dimensional accuracy of cone beam CT with varying angulation of the jaw to the X-ray beam
    Koch, George K.
    Hamilton, Adam
    Wang, Kelly
    Herschdorfer, Laura
    Lee, Kyu Ha
    Gallucci, German O.
    Friedland, Bernard
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (04)
  • [43] X-ray scatter suppression algorithm for cone beam volume CT
    Ning, RL
    Tang, XY
    Conover, DL
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 774 - 781
  • [44] An X-Ray Fluence Modulation Apparatus for Cone-Beam CT
    Ghazi, P.
    Youssefian, S.
    Ghazi, T.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [45] Phase Contrast Cone Beam Tomography with an X-Ray Grating Interferometer
    Jerjen, I.
    Revol, V.
    Kottler, C.
    Luethi, Th.
    Sennhauser, U.
    Kaufmann, R.
    Urban, C.
    INTERNATIONAL CONFERENCE ON ADVANCED PHASE MEASUREMENT METHODS IN OPTICS AN IMAGING, 2010, 1236 : 227 - +
  • [46] The use of the X-ray in the diagnosis of pulmonary tuberculosis
    Minor, CL
    BULLETIN OF THE JOHNS HOPKINS HOSPITAL, 1910, 21 : 263 - 269
  • [47] The use of a radiolucent template to improve bone age X-ray quality (BASIC study)
    Cockill, Toby G.
    Hewitt, Amanda
    Heafey, Christopher
    Wright, Neil P.
    Elder, Charlotte J.
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2017, 30 (12): : 1277 - 1280
  • [48] Optimizing beam quality for X-ray computed mammotomography
    McKinley, RL
    Tornai, MP
    Samei, E
    Bradshaw, ML
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 575 - 584
  • [49] VERTICAL ANGULATION OF THE X-RAY-BEAM AND RADIOGRAPHIC DIAGNOSIS OF SECONDARY CARIES
    TVEIT, AB
    ESPELID, I
    ERICKSON, RL
    GLASSPOOLE, EA
    COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1991, 19 (06) : 333 - 335
  • [50] Quality control of measured x-ray beam data
    Bjarngard, BE
    Vadash, P
    Ceberg, CP
    MEDICAL PHYSICS, 1997, 24 (09) : 1441 - 1444