Use of an x-ray beam-limiting cone to improve radiographic quality in diagnosis of traumatic reticuloperitonitis

被引:0
|
作者
Pravettoni, Davide [1 ]
Zani, Davide D. [2 ]
Biggi, Marianna [2 ]
Morandi, Nicola [1 ]
Di Giancamillo, Mauro [2 ]
Bertagnoli, Alberto [1 ]
Belloli, Angelo G. [1 ]
机构
[1] Univ Milan, Clin Ruminanti & Suino, Osped Vet Grandi Anim, Dipartimento Sci Clin Vet, I-26900 Lodi, Italy
[2] Sez Radiol Vet Clin & Sperimentale, I-26900 Lodi, Italy
来源
DEUTSCHE TIERARZTLICHE WOCHENSCHRIFT | 2009年 / 116卷 / 12期
关键词
traumatic reticuloperitonitis; cow; radiography; x-ray beam-limiting cone; diagnostic imaging; COWS; CATTLE;
D O I
10.2376/0341-6593-116-429
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
To evaluate the quality and the diagnostic relevance of the radiographs of the reticular area obtained using an x-ray beam-limiting cone (LC), both conventional and LC images were analysed in 12 cows affected by traumatic reticuloperitonitis (TRP). The improvement in resolution, definition and contrast of the LC images and a clinical assessment of the diagnostic relevance of the procedure were scored. The use of LC improved the quality of the radiographs in 10 cases (83%) thanks to an improvement in the resolution (67%), definition (58%) and contrast (83%). The procedure was diagnostically relevant in 5 cases (42%), facilitating the detection of details not clearly visualised by previous conventional survey radiographs: a very thin foreign body responsible of TRF, a mass in the ventro-caudal contour of the reticulum, the exact position of the foreign bodies. A consistency test for the x-rays was performed in a clinically healthy cow to confirm the improvement in the radiographic quality determined by the procedure. Although conventional imaging is often sufficient to confirm diagnosis of TRP, the use of the LC improves the quality of reticular radiographs and in several cases can be fundamental for the identification of a thin foreign body or a lesion.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [31] Sensitometer for quality assurance in X-ray diagnosis
    Buhr, E
    Czaske, M
    PTB-MITTEILUNGEN, 1998, 108 (05): : 400 - 401
  • [32] Quality control and guarantee in X-ray diagnosis
    Polovchik, M.
    Medicinskaa radiologia, 1992, 37 (7-8): : 4 - 8
  • [33] USE OF METHOD OF DIVERGENT X-RAY BEAM IN X-RAY STRUCTURAL ANALYSIS (REVIEW)
    PEKAREV, AI
    CHISTYAKOV, YD
    INDUSTRIAL LABORATORY, 1969, 35 (09): : 1291 - +
  • [34] Assessment of Absorbed Dose and Image Quality Using Cone Beam CT On An X-Ray Angiography System
    Supanich, M.
    Vanderhoek, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [35] Cone-beam X-ray tomographic and stereo-imaging
    Wang, Ge
    Zhao, Shiying
    Cheng, Ping-Chin
    1996, Center for Biomedical Engineering, NTU College of Medicine, Taipei, Taiwan (08):
  • [36] A helium-purged beam path to improve soft and softer X-ray data quality
    Polentarutti, M
    Glazer, R
    Carugoa, KD
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2004, 37 : 319 - 324
  • [37] X-ray scatter correction algorithm for cone beam CT imaging
    Ning, R
    Tang, XY
    Conover, D
    MEDICAL PHYSICS, 2004, 31 (05) : 1195 - 1202
  • [38] Recent Advances in X-ray Cone-beam Computed Laminography
    O'Brien, Neil S.
    Boardman, Richard P.
    Sinclair, Ian
    Blumensath, Thomas
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (05) : 691 - 707
  • [39] Optimal specimen placement in cone beam X-ray computed tomography
    Heinzl, C.
    Kastner, J.
    Amirkhamov, A.
    Groeller, E.
    Gusenbauer, C.
    NDT & E INTERNATIONAL, 2012, 50 : 42 - 49
  • [40] Multisource X-Ray System for Artifact Reduction in Cone Beam CT
    Becker, A.
    Hernandez, A.
    Schwoebel, P.
    Boone, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3177 - 3178