Use of an x-ray beam-limiting cone to improve radiographic quality in diagnosis of traumatic reticuloperitonitis

被引:0
|
作者
Pravettoni, Davide [1 ]
Zani, Davide D. [2 ]
Biggi, Marianna [2 ]
Morandi, Nicola [1 ]
Di Giancamillo, Mauro [2 ]
Bertagnoli, Alberto [1 ]
Belloli, Angelo G. [1 ]
机构
[1] Univ Milan, Clin Ruminanti & Suino, Osped Vet Grandi Anim, Dipartimento Sci Clin Vet, I-26900 Lodi, Italy
[2] Sez Radiol Vet Clin & Sperimentale, I-26900 Lodi, Italy
来源
DEUTSCHE TIERARZTLICHE WOCHENSCHRIFT | 2009年 / 116卷 / 12期
关键词
traumatic reticuloperitonitis; cow; radiography; x-ray beam-limiting cone; diagnostic imaging; COWS; CATTLE;
D O I
10.2376/0341-6593-116-429
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
To evaluate the quality and the diagnostic relevance of the radiographs of the reticular area obtained using an x-ray beam-limiting cone (LC), both conventional and LC images were analysed in 12 cows affected by traumatic reticuloperitonitis (TRP). The improvement in resolution, definition and contrast of the LC images and a clinical assessment of the diagnostic relevance of the procedure were scored. The use of LC improved the quality of the radiographs in 10 cases (83%) thanks to an improvement in the resolution (67%), definition (58%) and contrast (83%). The procedure was diagnostically relevant in 5 cases (42%), facilitating the detection of details not clearly visualised by previous conventional survey radiographs: a very thin foreign body responsible of TRF, a mass in the ventro-caudal contour of the reticulum, the exact position of the foreign bodies. A consistency test for the x-rays was performed in a clinically healthy cow to confirm the improvement in the radiographic quality determined by the procedure. Although conventional imaging is often sufficient to confirm diagnosis of TRP, the use of the LC improves the quality of reticular radiographs and in several cases can be fundamental for the identification of a thin foreign body or a lesion.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [1] COMPARISON OF A RADIOGRAPHIC MEASUREMENT OF X-RAY BEAM QUALITY WITH SPECTRAL MEASUREMENTS
    ARDRAN, GM
    BURT, AK
    CROOKS, HE
    PEAPLE, LHJ
    BRITISH JOURNAL OF RADIOLOGY, 1969, 42 (502): : 757 - &
  • [2] X-Ray Beam-Width Limiting Device
    William, Wasswa
    de Jager, Kylie
    John, Lester
    Steiner, Stefan
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (02):
  • [3] Coherent Cone-Beam X-ray Microscopy
    Harder, R.
    Xiao, X.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 429 - 432
  • [4] ALIGNMENT OF LIGHT-LOCALIZED BEAM AND RADIOGRAPHIC X-RAY BEAM
    ESSENBUR.A
    KOZIARSK.B
    RADIOLOGY, 1972, 104 (03) : 716 - &
  • [5] SPECIFICATION OF X-RAY BEAM QUALITY
    TROUT, ED
    KELLEY, JP
    HEALTH PHYSICS, 1970, 19 (02): : 350 - +
  • [6] X-RAY DIAGNOSIS OF TRAUMATIC SPLEEN RUPTURE
    HARTEL, M
    SCHNAARS, P
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1972, 97 (13) : 517 - &
  • [7] Investigation of a Diamond X-Ray Target for Use with Megavoltage Cone-Beam CT
    Sawkey, D.
    Lu, M.
    Wu, V.
    Faddegon, B.
    Morin, O.
    Cheung, J.
    Aubin, M.
    Gangadharan, B.
    Bani-Hashemi, A.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [8] Cone-beam x-ray tomography with arbitrary-orientation x-ray tube
    Sueseenak, D.
    Chanwimalueang, T.
    Narkbuekaew, W.
    Chitsakul, K.
    Pintavirooj, C.
    ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1631 - 1634
  • [9] Cone-beam X-ray tomography with arbitrary-orientation X-ray ribe
    Sueseenak, D.
    Chanwimalueang, T.
    Narkbuekaew, W.
    Chitsakul, K.
    Pintavirooj, C.
    2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, 2006, : 1300 - +
  • [10] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)