Simultaneous refractive index and thickness measurements of bio tissue by optical coherence tomography

被引:65
|
作者
Wang, XY [1 ]
Zhang, CP [1 ]
Zhang, LS [1 ]
Xue, LL [1 ]
Tian, JG [1 ]
机构
[1] Nankai Univ, Dept Phys, Tianjin 300071, Peoples R China
关键词
optical coherence tomography; refractive index; bio tissue;
D O I
10.1117/1.1501887
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents two techniques based on optical coherence tomography, the "focus tracking method" and the "optical path shifting method," for determining refractive index and thickness simultaneously, which are especially useful for bio tissues. From comparison of these two methods, it was found that the focus tracking method is suitable for in vivo measurement, but does not have high precision. The optical path shifting method is limited to in vitro measurement, but has high precision. Using the optical path shifting method, the refractive indices of cucumber were measured at the wavelength of 850 and 1300 nm. (C) 2002 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:628 / 632
页数:5
相关论文
共 50 条
  • [41] Tissue clearing of bio-tissues for optical coherence tomography
    Wang, RKK
    [J]. OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 241 - 244
  • [42] In vivo tissue measurements with optical low coherence tomography
    Lankenau, E
    Welzel, J
    Birngruber, R
    Engelhardt, R
    [J]. COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS, PROCEEDINGS OF, 1997, 2981 : 78 - 84
  • [43] Reproducibility of retinal thickness measurements using Optical Coherence Tomography
    Wang, RC
    Koozekanani, D
    Herderick, EE
    Roberts, C
    Katz, SE
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [44] Automated measurements of retinal thickness with optical coherence tomography - Reply
    Ray, R
    Stinnett, SS
    Jaffe, GJ
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 351 - 351
  • [45] Errors in retinal thickness measurements obtained by optical coherence tomography
    Sadda, SR
    Wu, ZQ
    Walsh, AC
    Richine, L
    Dougall, J
    Cortez, R
    LaBree, LD
    [J]. OPHTHALMOLOGY, 2006, 113 (02) : 285 - 293
  • [46] Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography
    Muscat, S
    McKay, N
    Parks, S
    Kemp, E
    Keating, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (06) : 1791 - 1795
  • [47] Refractive index tomography of turbid media by bifocal optical coherence refractometry
    Zvyagin, AV
    Silva, KKMBD
    Alexandrov, SA
    Hillman, TR
    Armstrong, JJ
    Tsuzuki, T
    Sampson, DD
    [J]. OPTICS EXPRESS, 2003, 11 (25): : 3503 - 3517
  • [48] Refractive index tomography of turbid media by bifocal optical coherence refractometry
    Zvyagin, AV
    Alexandrov, SA
    Silva, KKMBD
    Hillman, TR
    Armstrong, JJ
    Tsuzuki, T
    Sampson, DD
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 155 - 166
  • [49] Refractive index correction in optical coherence tomography images of multilayer tissues
    Turani, Zahra
    Fatemizadeh, Emad
    Xu, Qiuyun
    Daveluy, Steven
    Mehregan, Darius
    Nasiriavanaki, Mohammadreza
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (07)
  • [50] Measurement of a Turbid Medium's Refractive Index with Optical Coherence Tomography
    Feng Yinqi
    Liu Yaoqin
    [J]. 5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2010, 7656