Initial Evaluation of a 2D Diode Array for Quality Assurance of Radiosurgery Treatments

被引:3
|
作者
Carlos Ronquillo-Gomez, Roberto [1 ]
Hernandez-Bojorquez, Mariana [1 ,2 ]
Javier Uriarte-Rivera, Hector [1 ]
de la Mata, Dolores [2 ]
Moreno-Jimenez, Sergio [3 ]
Flores-Vazquez, Fabiola [2 ]
机构
[1] Inst Politecn Nacl, Escuela Super Fis & Matemat, Mexico City, DF, Mexico
[2] Amer British Cowdray Med Ctr, Ctr Canc, Mexico City, DF, Mexico
[3] Amer British Cowdray Med Ctr, Ctr Neurol, Mexico City, DF, Mexico
来源
关键词
D O I
10.1063/1.5095894
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study we investigate the performance of a new commercial 2D diode array SRS MapCHECK (TM) for its clinical use. The performance of the SRS MapCHECK (TM) was evaluated using wedge profiles compared with EBT3 radiochromic film measurements and with the profiles obtained from the treatment planning system. The results show a good correspondence between the two dosimeters. The absolute dosimetric evaluation for an end to end test with EBT3 film and PinPoint 3D ionization chamber was performed and the results showed local percentage differences less than 1.1% in both cases. Ten intracranial radiosurgery treatment plans were irradiated with all fields composite at 0 degrees and the measured dose distributions were compared with the calculated ones. The average for gamma index result of (2%/1.5mm) was 97.21%. The SRS MapCHECK (TM) offers the dosimetric characteristics required in relative and absolute dosimetry for the verification of intracranial radiosurgery treatments (in restricted collapsed test of gantry at 0 degrees).
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Evaluation of a 2D diode array for IMRT quality assurance
    Létourneau, D
    Gulam, M
    Yan, D
    Oldham, M
    Wong, JW
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 70 (02) : 199 - 206
  • [2] Quality assurance of asymmetric jaw alignment using 2D diode array
    Kim, Sun Mo
    Chmielewski, Renata
    Abbas, Ahmar
    Yeung, Ivan W. T.
    Moseley, Douglas J.
    [J]. MEDICAL PHYSICS, 2013, 40 (12)
  • [3] The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance
    Espinoza, A.
    Petasecca, M.
    Fuduli, I.
    Howie, A.
    Bucci, J.
    Corde, S.
    Jackson, M.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    [J]. MEDICAL PHYSICS, 2015, 42 (02) : 663 - 673
  • [4] Evaluation of a 2D diode array for IMRT QA
    Letourneau, D
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1396 - 1396
  • [5] Evaluation of a high resolution diode array for CyberKnife quality assurance
    Garcia-Fuentes, Juan D. D.
    Sevillano, David
    Colmenares, Rafael
    Capuz, Ana B. B.
    Moris, Rafael
    Camara, Miguel
    Galiano, Pablo
    Williamson, Sandra
    Bejar, Maria J.
    Prieto, Daniel
    Garcia-Vicente, Feliciano
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (09):
  • [6] EVALUATION OF A HELICAL DIODE ARRAY DEVICE FOR IMRT QUALITY ASSURANCE
    Eenink, M.
    Van Egmond, J.
    Roijen, E.
    de Goede, M.
    Petoukhova, A.
    Rietveld, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S456 - S456
  • [7] Comprehensive quality assurance for stereotactic radiosurgery treatments
    Ramaseshan, R
    Heydarian, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (14): : N199 - N205
  • [8] LINAC QUALITY ASSURANCE USING A 2D DIODE ARRAY DEVICE: IS IT REALLY NECESSARY THE 3D WATER PHANTOM YET?
    Rodriguez Garcia, A.
    Sanchez-Reyes Fernandez, A.
    Loscos, S.
    Vila, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S519 - S519
  • [9] EVALUATION OF A 2D ARRAY FOR LINAC QUALITY CONTROL
    Pimentel Batel, V. I.
    Figueira, A. R.
    Trindade, M.
    Carvalho, A. L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S398 - S398
  • [10] Characterization of the First Prototype of an Angular Independent Silicon Diode Array for Quality Assurance in Stereotactic Radiosurgery
    Bashiri, Aishah
    Hood, Sean
    Posar, Jessie
    Dookie, Yashiv
    McNamara, Joanne
    Poder, Joel
    Zahra, Fathimat
    Lerch, Michael L. F.
    Rosenfeld, Anatoly B.
    Petasecca, Marco
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (13):