Evaluation of a 2D diode array for IMRT quality assurance

被引:190
|
作者
Létourneau, D [1 ]
Gulam, M [1 ]
Yan, D [1 ]
Oldham, M [1 ]
Wong, JW [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
关键词
intensity modulated radiation therapy; quality assurance; diode array;
D O I
10.1016/j.radonc.2003.10.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: The QA of intensity modulated radiotherapy (IMRT) dosimetry is a laborious task. The goal of this work is to evaluate the dosimetric characteristics of a new 2D diode array (MapCheck from Sun Nuclear Corporation, Melbourne, Florida) and assess the role it can play in routine IMRT QA. Material and methods: Fundamental properties of the MapCheck such as reproducibility, linearity and temperature dependence are studied for high-energy photon beams. The accuracy of the correction for difference of diode sensitivity is also assessed. The diode array is benchmarked against film and ion chambers for conventional and IMRT treatments. The MapCheck sensitivity to multileaf collimator position errors is determined. Results: The diode array response is linear with dose up to 295 cGy. All diodes are calibrated to within +/-1% of each other, and mostly within +/-0.5%. The MapCheck readings are reproducible to within a maximum SD of +/-0.15%. A temperature dependence of 0.57%/degreesC was noted and should be taken into account for absolute dosimetric measurement. Clinical performance of the MapCheck for relative and absolute dosimetry is demonstrated with seven beam (6 MV) head and neck IMRT plans, and compares well with film and ion chamber measurements. Comparison to calculated dose maps demonstrates that the planning system model underestimates the dose gradients in the penumbra region. Conclusions: The MapCheck offers the dosimetric characteristics required for performing both relative and absolute dose measurements. Its use in the clinic can simplify and reduce the IMRT QA workload. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 50 条
  • [1] Evaluation of a 2D diode array for IMRT QA
    Letourneau, D
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1396 - 1396
  • [2] Initial Evaluation of a 2D Diode Array for Quality Assurance of Radiosurgery Treatments
    Carlos Ronquillo-Gomez, Roberto
    Hernandez-Bojorquez, Mariana
    Javier Uriarte-Rivera, Hector
    de la Mata, Dolores
    Moreno-Jimenez, Sergio
    Flores-Vazquez, Fabiola
    [J]. XV MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2019, 2090
  • [3] EVALUATION OF A HELICAL DIODE ARRAY DEVICE FOR IMRT QUALITY ASSURANCE
    Eenink, M.
    Van Egmond, J.
    Roijen, E.
    de Goede, M.
    Petoukhova, A.
    Rietveld, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S456 - S456
  • [4] IMRT QA with a 2D diode array
    Ding, L
    Ahluwalia, W
    Liu, C
    Li, J
    Palta, J
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1396 - 1396
  • [5] Quality assurance of asymmetric jaw alignment using 2D diode array
    Kim, Sun Mo
    Chmielewski, Renata
    Abbas, Ahmar
    Yeung, Ivan W. T.
    Moseley, Douglas J.
    [J]. MEDICAL PHYSICS, 2013, 40 (12)
  • [6] Performance assessment of a 2D array of plastic scintillation detectors for IMRT quality assurance
    Guillot, Mathieu
    Gingras, Luc
    Archambault, Louis
    Beddar, Sam
    Beaulieu, Luc
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13): : 4439 - 4454
  • [7] Evaluation of a biplanar diode array dosimeter for quality assurance of step-and-shoot IMRT
    Feygelman, Vladimir
    Forster, Kenneth
    Opp, Daniel
    Nilsson, Gorgen
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04): : 64 - 78
  • [8] A method to enhance 2D ion chamber array patient specific quality assurance for IMRT
    Diaz Moreno, Rogelio Manuel
    Venencia, Daniel
    Garrigo, Edgardo
    Pipman, Yakov
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 145 - 151
  • [9] A method to enhance 2D ion chamber array patient specific quality assurance for IMRT
    Rogelio Manuel Diaz Moreno
    Daniel Venencia
    Edgardo Garrigo
    Yakov Pipman
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 145 - 151
  • [10] The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance
    Espinoza, A.
    Petasecca, M.
    Fuduli, I.
    Howie, A.
    Bucci, J.
    Corde, S.
    Jackson, M.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    [J]. MEDICAL PHYSICS, 2015, 42 (02) : 663 - 673