3D-imaging using micro-PIXE

被引:11
|
作者
Ishii, K. [1 ]
Matsuyama, S. [1 ]
Watanabe, Y. [1 ]
Kawamura, Y. [1 ]
Yamaguchi, T. [1 ]
Oyama, R. [1 ]
Momose, G. [1 ]
Ishizaki, A. [1 ]
Yamazaki, H. [1 ]
Kikuchi, Y. [1 ]
机构
[1] Tohoku Univ, Grad Sch Engn, Dept Quantum Sci & Energy Engn, Aoba Ku, Sendai, Miyagi 9808579, Japan
关键词
micron-CT; 3D-CT; PIXE; X-ray CCD camera;
D O I
10.1016/j.nima.2006.10.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a 3D-imaging system using characteristic X-rays produced by proton micro-beam bombardment. The 3D-imaging system consists of a micro-beam and an X-ray CCD camera of 1 mega pixels (Hamamatsu photonics C8800X), and has a spatial resolution of 4 mu m by using characteristic Ti-K-X-rays (4.558 keV) produced by 3 MeV protons of beam spot size of similar to 1 mu m. We applied this system, namely, a micron-CT to observe the inside of a living small ant's head of similar to 1 mm diameter. An ant was inserted into a small polyimide tube the inside diameter and the wall thickness of which are 1000 and 25 mu m, respectively, and scanned by the micron-CT. Three dimensional images of the ant's heads were obtained with a spatial resolution of 4 mu m. It was found that, in accordance with the strong dependence on atomic number of photo ionization cross-sections, the mandibular gland of ant contains heavier elements, and moreover, the CT-image of living ant anaesthetized by chloroform is quite different from that of a dead ant dipped in formalin. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 50 条
  • [1] Investigation of turquoise gemstone using micro-PIXE imaging technique
    Nikbakht, T.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 484 : 5 - 11
  • [2] Micro-PIXE imaging of the rib bones of rats
    Yakumaru, Haruko
    Kato, Yugo
    Oikawa, Masakazu
    Numako, Chiya
    Ohsawa, Daisuke
    Tanaka, Izumi
    Uehara, Akihiro
    Ishihara, Hiroshi
    Homma-Takeda, Shino
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2024, 553
  • [3] Micro-PIXE in ecophysiology
    Przybylowicz, WJ
    Mesjasz-Przybylowicz, J
    Migula, P
    Nakonieczny, M
    Augustyniak, M
    Tarnawska, M
    Turnau, K
    Ryszka, P
    Orlowska, E
    Zubek, S
    Glowacka, E
    [J]. X-RAY SPECTROMETRY, 2005, 34 (04) : 285 - 289
  • [4] On the characterization of the "Paris" meteorite using PIXE, RBS and micro-PIXE
    Noun, M.
    Roumie, M.
    Calligaro, T.
    Nsouli, B.
    Brunetto, R.
    Baklouti, D.
    d'Hendecourt, L.
    Della-Negra, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 306 : 261 - 264
  • [5] Elemental imaging of rat epididymis by micro-PIXE analysis
    Homma-Takeda, S
    Nishimura, Y
    Watanabe, Y
    Imaseki, H
    Yukawa, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 210 : 368 - 372
  • [6] 3D-reconstruction of an object by means of a confocal micro-PIXE
    Zitnik, Matjaz
    Grlj, Natasa
    Vaupetic, Primoz
    Pelicon, Primoz
    Bucar, Klemen
    Sokaras, Dimosthenis
    Karydas, Andreas Germanos
    Kanngiesser, Birgit
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (01) : 28 - 33
  • [7] MICRO-PIXE ANALYSIS IN MINERALOGY AND GEOCHEMISTRY
    CAMPBELL, JL
    TEESDALE, WJ
    HALDEN, NM
    [J]. GEOSCIENCE CANADA, 1992, 19 (04) : 175 - 179
  • [8] MICRO-PIXE QUANTIFICATION OF HISTOCHEMICAL REACTIONS
    ROKITA, E
    CICHOCKI, T
    DIVOUX, S
    GONSIOR, B
    HOFERT, M
    JARCZYK, L
    STRZALKOWSKI, A
    SYCH, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 441 - 445
  • [9] Analysis of heterogenized zirconocene catalysts using a micro-PIXE technique
    M. Atiqullah
    M. Ahmed
    M. Akhtar
    S. Ahmed
    J. Khan
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 1999, 240 : 893 - 896
  • [10] MICRO-PIXE WITHIN MAGMATIC INCLUSIONS USING GUPIX SOFTWARE
    MOSBAH, M
    PICCOT, D
    CLOCCHIATTI, R
    METRICH, N
    GOSSET, J
    JORON, JL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 82 (01): : 139 - 145