3D-imaging using micro-PIXE

被引:11
|
作者
Ishii, K. [1 ]
Matsuyama, S. [1 ]
Watanabe, Y. [1 ]
Kawamura, Y. [1 ]
Yamaguchi, T. [1 ]
Oyama, R. [1 ]
Momose, G. [1 ]
Ishizaki, A. [1 ]
Yamazaki, H. [1 ]
Kikuchi, Y. [1 ]
机构
[1] Tohoku Univ, Grad Sch Engn, Dept Quantum Sci & Energy Engn, Aoba Ku, Sendai, Miyagi 9808579, Japan
关键词
micron-CT; 3D-CT; PIXE; X-ray CCD camera;
D O I
10.1016/j.nima.2006.10.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a 3D-imaging system using characteristic X-rays produced by proton micro-beam bombardment. The 3D-imaging system consists of a micro-beam and an X-ray CCD camera of 1 mega pixels (Hamamatsu photonics C8800X), and has a spatial resolution of 4 mu m by using characteristic Ti-K-X-rays (4.558 keV) produced by 3 MeV protons of beam spot size of similar to 1 mu m. We applied this system, namely, a micron-CT to observe the inside of a living small ant's head of similar to 1 mm diameter. An ant was inserted into a small polyimide tube the inside diameter and the wall thickness of which are 1000 and 25 mu m, respectively, and scanned by the micron-CT. Three dimensional images of the ant's heads were obtained with a spatial resolution of 4 mu m. It was found that, in accordance with the strong dependence on atomic number of photo ionization cross-sections, the mandibular gland of ant contains heavier elements, and moreover, the CT-image of living ant anaesthetized by chloroform is quite different from that of a dead ant dipped in formalin. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 50 条
  • [41] The kinetics of Fe and Ca for the development of radiation-induced apoptosis by micro-PIXE imaging
    Harada, S
    Tamakawa, Y
    Ishii, K
    Tanaka, A
    Satoh, T
    Matsuyama, S
    Yamazaki, H
    Komori, Y
    Kamiya, T
    Sakai, T
    Arakawa, K
    Saitoh, M
    Oikawa, M
    Sera, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 210 : 383 - 387
  • [42] Towards the 3D-imaging of sources
    Danielewicz, P
    Brown, DA
    Heffner, M
    Pratt, S
    Soltz, R
    [J]. ACTA PHYSICA HUNGARICA A-HEAVY ION PHYSICS, 2005, 22 (3-4): : 253 - 262
  • [43] Importance of 3D-imaging in periodontology
    Hassfeld, S.
    [J]. MKG-CHIRURG, 2011, 4 (04): : 307 - 309
  • [44] THE INFLUENCE OF SAMPLE ROUGHNESS ON THE QUANTIFICATION OF MICRO-PIXE RESULTS
    ORLIC, I
    VANLANGEVELDE, F
    VIS, RD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 74 - 77
  • [45] Micro-PIXE in plant sciences: Present status and perspectives
    Mesjasz-Przybylowicz, J
    Przybylowicz, WJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 189 : 470 - 481
  • [46] WEAR STUDIES OF TUNGSTEN CARBIDE CUTTING TOOLS USING THE MICRO-PIXE TECHNIQUE
    SHUAIB, AN
    NICKEL, J
    AHMED, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 103 (01): : 68 - 72
  • [47] Micro-PIXE studies of char populations in northern Canada
    Campbell, JL
    Babaluk, JA
    Halden, NM
    Kristofferson, AH
    Maxwell, JA
    Mejia, SR
    Reist, JD
    Teesdale, WJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 150 (1-4): : 260 - 266
  • [48] Analysis of geological samples by the micro-PIXE facility at KFUPM
    Ahmed, M
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 265 (01) : 39 - 45
  • [49] PIXE and micro-PIXE studies of ion release around endosseous implants in animals
    Egeni, GP
    Jaksic, M
    Moschini, G
    Passi, P
    Piattelli, A
    Rossi, P
    Rudello, V
    Tauro, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 109 : 289 - 293
  • [50] Nickel-Germanium Lateral Diffusion Study Using Micro-RBS and Micro-PIXE
    Habanyama, A.
    Pineda-Vargas, C. A.
    Comrie, C. M.
    Chilukusha, D.
    Nemutudi, R.