Quantitative analysis of template-based attenuation compensation in 3D brain PET

被引:15
|
作者
Montandon, Marie-Louise [1 ]
Zaidi, Habib [1 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med, CH-1211 Geneva 4, Switzerland
关键词
PET; attenuation correction; brain imaging; template; quantitative analysis;
D O I
10.1016/j.compmedimag.2006.09.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An atlas-guided attenuation correction method was recently proposed for 3D brain positron emission tomography (PET) imaging eliminating the need for acquisition of a patient-specific measured transmission scan. The algorithm was validated through comparison to transmission-based attenuation correction (gold standard) using voxelwise statistical parametric mapping (SPM) analysis of clinical data. In contrast to brain 'activation' studies for which SPM is primarily developed, brain PET research studies often involve absolute quantification. In the preliminary validation study published earlier, there is no validation as to how such quantification can be affected by the two methods as the assessment was carried out by an SPM group analysis alone. It is quite important to demonstrate how the proposed method performs individually, particularly for diagnostic applications or individual quantification. In this study, we assess the quantitative accuracy of this method in clinical setting using automated volume of interest (VOI)-based analysis by means of the commercially available BRASS software. There is a very good correlation (R-2 = 0.91) between the atlas-guided and measured transmission-guided attenuation correction techniques and the regression line agreed well with the line of identity (slope = 0.96) for the grouped analysis of patient data. The mean relative difference between the two methods for all VOIs across the whole population is 2.3% whereas the maximum difference is less than 7%. No proof of statistically significant differences could be verified for all regions. These encouraging results provide further confidence in the adequacy of the proposed approach demonstrating its performance particularly for research studies or diagnostic applications involving quantification. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 38
页数:11
相关论文
共 50 条
  • [41] Compensation for head movement in 3D PET
    Fulton, RR
    Tellmann, L
    Pietrzyk, U
    Herzog, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2013 - 2017
  • [42] Quantitative analysis of extrastriatal dopamine D2 receptors in the human brain by 3D PET.
    Suhara, T
    Sudo, Y
    Suzuki, K
    Okauchi, T
    Farde, L
    Halldin, C
    Tanada, S
    Sasaki, Y
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 72P - 72P
  • [43] Comparative evaluation of template-based region sampling for PiB PET data analysis
    Laymon, Charles M.
    Rosario, Bedda L.
    Redfield, Andrew
    Berginc, Michael
    Klunk, William E.
    Mathis, Chester A.
    Price, Julie C.
    NEUROIMAGE, 2010, 52 : S219 - S219
  • [44] Quantitative brain PET: Comparison of 2D and 3D acquisitions.
    Dhawan, V
    Kazumata, K
    Robeson, W
    Belakhlef, A
    Margouleff, C
    Chaly, T
    Antonini, A
    Eidelberg, D
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 835 - 835
  • [45] NECR ANALYSIS OF 3D BRAIN PET SCANNER DESIGNS
    STEARNS, CW
    CHERRY, SR
    THOMPSON, CJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1075 - 1079
  • [46] A phantom study evaluating the quantitative aspect of 3D PET imaging of the brain
    Sossi, V
    Oakes, TR
    Ruth, TJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (09): : 2615 - 2630
  • [47] ACCURATE ATTENUATION CORRECTION FOR A 3D PET SYSTEM
    MCKEE, BTA
    CLACK, R
    HARVEY, PJ
    HILTZ, LG
    HOGAN, MJ
    HOWSE, DC
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (05): : 603 - 619
  • [48] Template-Based 3D Reconstruction of Non-rigid Deformable Object from Monocular Video
    Liu, Yang
    Peng, Xiaodong
    Zhou, Wugen
    Liu, Bo
    Gerndt, Andreas
    3D RESEARCH, 2018, 9 (02):
  • [49] Template-Based Isometric Deformable 3D Reconstruction with Sampling-Based Focal Length Self-Calibration
    Bartoli, Adrien
    Collins, Toby
    2013 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2013, : 1514 - 1521
  • [50] PDBSite database and PDBSiteScan tool: Recognition of functional sites in protein 3d structure and template-based docking
    Ivanisenko, V. A.
    Ivanisenko, T., V
    Sharonova, I., V
    Krestyanova, M. A.
    Ivanisenko, N., V
    Grigorovich, D. A.
    PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON BIOINFORMATICS OF GENOME REGULATION AND STRUCTURE, VOL 1, 2006, : 272 - +