Quantitative analysis of template-based attenuation compensation in 3D brain PET

被引:15
|
作者
Montandon, Marie-Louise [1 ]
Zaidi, Habib [1 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med, CH-1211 Geneva 4, Switzerland
关键词
PET; attenuation correction; brain imaging; template; quantitative analysis;
D O I
10.1016/j.compmedimag.2006.09.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An atlas-guided attenuation correction method was recently proposed for 3D brain positron emission tomography (PET) imaging eliminating the need for acquisition of a patient-specific measured transmission scan. The algorithm was validated through comparison to transmission-based attenuation correction (gold standard) using voxelwise statistical parametric mapping (SPM) analysis of clinical data. In contrast to brain 'activation' studies for which SPM is primarily developed, brain PET research studies often involve absolute quantification. In the preliminary validation study published earlier, there is no validation as to how such quantification can be affected by the two methods as the assessment was carried out by an SPM group analysis alone. It is quite important to demonstrate how the proposed method performs individually, particularly for diagnostic applications or individual quantification. In this study, we assess the quantitative accuracy of this method in clinical setting using automated volume of interest (VOI)-based analysis by means of the commercially available BRASS software. There is a very good correlation (R-2 = 0.91) between the atlas-guided and measured transmission-guided attenuation correction techniques and the regression line agreed well with the line of identity (slope = 0.96) for the grouped analysis of patient data. The mean relative difference between the two methods for all VOIs across the whole population is 2.3% whereas the maximum difference is less than 7%. No proof of statistically significant differences could be verified for all regions. These encouraging results provide further confidence in the adequacy of the proposed approach demonstrating its performance particularly for research studies or diagnostic applications involving quantification. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 38
页数:11
相关论文
共 50 条
  • [21] Template-based method for multiple volumes of interest of human brain PET images
    Yasuno, F
    Hasnine, AH
    Suhara, T
    Ichimiya, T
    Sudo, Y
    Inoue, M
    Takano, A
    Ou, T
    Ando, T
    Toyama, H
    NEUROIMAGE, 2002, 16 (03) : 577 - 586
  • [22] Template-based Monocular 3D Recovery of Elastic Shapes using Lagrangian Multipliers
    Haouchine, Nazim
    Cotin, Stephane
    30TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2017), 2017, : 3578 - 3586
  • [23] DTI template-based estimation of cardiac fiber orientations from 3D ultrasound
    Qin, Xulei
    Fei, Baowei
    MEDICAL PHYSICS, 2015, 42 (06) : 2915 - 2924
  • [24] Monocular Template-Based 3D Reconstruction of Extensible Surfaces with Local Linear Elasticity
    Malti, Abed
    Hartley, Richard
    Bartoli, Adrien
    Kim, Jae-Hak
    2013 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2013, : 1522 - 1529
  • [25] A template-based knowledge reuse method for generating multitype 3D railway scenes
    Zhang, Heng
    Zhu, Jun
    Zhu, Qing
    Qi, Hua
    Wang, Changjin
    Han, Zujie
    Hu, Ya
    Ning, Xinwen
    INTERNATIONAL JOURNAL OF DIGITAL EARTH, 2018, 11 (02) : 179 - 194
  • [26] A Template-Based Method for Automatic Anthropometric Measurements from Multiple 3D Scans
    Garcia-D'Urso, Nahuel E.
    Azorin-Lopez, Jorge
    Fuster-Guillo, Andres
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON UBIQUITOUS COMPUTING & AMBIENT INTELLIGENCE (UCAMI 2022), 2023, 594 : 157 - 168
  • [27] Template-Based 3D Model Fitting Using Dual-Domain Relaxation
    Yeh, I-Cheng
    Lin, Chao-Hung
    Sorkine, Olga
    Lee, Tong-Yee
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2011, 17 (08) : 1178 - 1190
  • [28] Quantitative study of 18F-(+) DTBZ image: comparison of PET template-based and MRI based image analysis
    Lung, Hsu Jung
    Weng, Yi-Hsin
    Wen, Ming-Ching
    Hsiao, Ing-Tsung
    Lin, Kun-Ju
    SCIENTIFIC REPORTS, 2018, 8
  • [29] Quantitative study of 18F-(+)DTBZ image: comparison of PET template-based and MRI based image analysis
    Hsu Jung Lung
    Yi-Hsin Weng
    Ming-Ching Wen
    Ing-Tsung Hsiao
    Kun-Ju Lin
    Scientific Reports, 8
  • [30] Quantitative comparison of 3D and 2D PET with brain studies
    Sossi, V
    Oakes, TR
    Chan, G
    Ruth, TJ
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1438 - 1441