Segmentation of Corneal Optical Coherence Tomography Images Using Randomized Hough Transform

被引:3
|
作者
Elsawy, Amr [1 ,2 ]
Abdel-Mottaleb, Mohamed [1 ]
Abou Shousha, Mohamed [1 ,2 ]
机构
[1] Univ Miami, Elect & Comp Engn, 1251 Mem Dr, Coral Gables, FL 33146 USA
[2] Bascom Palmer Eye Inst, Ophthalmol, 900 NW 17th St, Miami, FL 33136 USA
来源
关键词
Randomized Hough Transform; Cornea Segmentation; OCT; GRAPH-THEORY; RECONSTRUCTION; DIAGNOSIS; MEMBRANE;
D O I
10.1117/12.2512865
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Measuring the thickness of different corneal microlayers is important for the diagnosis of common corneal eye diseases such as dry eye, keratoconus, Fuchs endothelial dystrophy, and corneal graft rejection. High resolution corneal images, obtained using optical coherence tomography (OCT), made it possible to measure the thickness of different corneal microlayers in vivo. The manual segmentation of these images is subjective and time consuming. Therefore, automatic segmentation is necessary. Several methods were proposed for segmenting corneal OCT images, but none of these methods segment all the microlayer interfaces and they are not robust. In addition, the lack of a large annotated database of corneal OCT images impedes the application of machine learning methods such as deep learning which proves to be very powerful. In this paper, we present a new corneal OCT image segmentation algorithm using Randomized Hough Transform. To the best of our knowledge, we developed the first automatic segmentation method for the six corneal microlayer interfaces. The proposed method includes a robust estimate of relative distances of inner corneal interfaces with respect to outer corneal interfaces. Also, it handles properly the correct ordering and the non-intersection of corneal microlayer interfaces. The proposed method was tested on 15 corneal OCT images that were randomly selected. OCT images were manually segmented by two trained operators for comparison. Comparison with the manual segmentation shows that the proposed method has mean segmentation error of 3.77 +/- 4.25 pixels across all interfaces which corresponds to 5.66 +/- 6.38 mu m. The mean segmentation error between the two manual operators is 4.07 +/- 4.71 pixels, which corresponds to 6.11 +/- 7.07 mu m. The proposed method takes a mean time of 2.59 +/- 0.06 seconds to segment six corneal interfaces.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Segmentation of Preretinal Space in Optical Coherence Tomography Images Using Deep Neural Networks
    Stankiewicz, Agnieszka
    Marciniak, Tomasz
    Dabrowski, Adam
    Stopa, Marcin
    Marciniak, Elzbieta
    Obara, Boguslaw
    SENSORS, 2021, 21 (22)
  • [32] Automatic Lumen Segmentation in Intravascular Optical Coherence Tomography Images Using Level Set
    Cao, Yihui
    Cheng, Kang
    Qin, Xianjing
    Yin, Qinye
    Li, Jianan
    Zhu, Rui
    Zhao, Wei
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2017, 2017
  • [33] Retinal layer and fluid segmentation in optical coherence tomography images using a hierarchical framework
    Melo, Tania
    Carneiro, Angela
    Campilho, Aurelio
    Mendonca, Ana Maria
    JOURNAL OF MEDICAL IMAGING, 2023, 10 (01)
  • [34] Fast segmentation of anterior segment optical coherence tomography images using graph cut
    Dominic Williams
    Yalin Zheng
    Fangjun Bao
    Ahmed Elsheikh
    Eye and Vision, 2
  • [35] Automatic Segmentation of Diffuse Retinal Thickening Edemas Using Optical Coherence Tomography Images
    Samagaio, Gabriela
    de Moura, Joaquim
    Novo, Jorge
    Ortega, Marcos
    KNOWLEDGE-BASED AND INTELLIGENT INFORMATION & ENGINEERING SYSTEMS (KES-2018), 2018, 126 : 472 - 481
  • [36] Automatic Segmentation of Corneal Lamellar Graft Surfaces from Low-Contrast Optical Coherence Tomography Images
    Arshavsky, Alec
    LaRocca, Francesco
    Izatt, Joseph
    Kuo, Anthony
    Farsiu, Sina
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [37] Optic nerve head segmentation using fundus images and optical coherence tomography images for glaucoma detection
    Babu, T. R. Ganesh
    Devi, S. Shenbaga
    Venkatesh, R.
    BIOMEDICAL PAPERS-OLOMOUC, 2015, 159 (04): : 607 - 615
  • [38] Contour segmentation using Hough Transform
    Bulot, R
    Boi, JM
    Sequeira, J
    Caprioglio, M
    INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, PROCEEDINGS - VOL III, 1996, : 583 - 586
  • [39] Hough transform for robust segmentation of underwater multispectral images
    Rivera-Maldonado, FJ
    Torres-Muñiz, RE
    Jiménez-Rodriguez, LO
    ALGORITHMS AND TECHNOLOGIES FOR MULTISPECTRAL, HYPERSPECTRAL AND ULTRASPECTRAL IMAGERY IX, 2003, 5093 : 591 - 600
  • [40] Automatic Measurement Method for Corneal Thickness of Optical Coherence Tomography Images
    Gao Yang
    Li Zhongliang
    Zhang Jianhua
    Nan Nan
    Wang Xuan
    Wang Xiangzhao
    ACTA OPTICA SINICA, 2019, 39 (03)