Segmentation of Corneal Optical Coherence Tomography Images Using Randomized Hough Transform

被引:3
|
作者
Elsawy, Amr [1 ,2 ]
Abdel-Mottaleb, Mohamed [1 ]
Abou Shousha, Mohamed [1 ,2 ]
机构
[1] Univ Miami, Elect & Comp Engn, 1251 Mem Dr, Coral Gables, FL 33146 USA
[2] Bascom Palmer Eye Inst, Ophthalmol, 900 NW 17th St, Miami, FL 33136 USA
来源
关键词
Randomized Hough Transform; Cornea Segmentation; OCT; GRAPH-THEORY; RECONSTRUCTION; DIAGNOSIS; MEMBRANE;
D O I
10.1117/12.2512865
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Measuring the thickness of different corneal microlayers is important for the diagnosis of common corneal eye diseases such as dry eye, keratoconus, Fuchs endothelial dystrophy, and corneal graft rejection. High resolution corneal images, obtained using optical coherence tomography (OCT), made it possible to measure the thickness of different corneal microlayers in vivo. The manual segmentation of these images is subjective and time consuming. Therefore, automatic segmentation is necessary. Several methods were proposed for segmenting corneal OCT images, but none of these methods segment all the microlayer interfaces and they are not robust. In addition, the lack of a large annotated database of corneal OCT images impedes the application of machine learning methods such as deep learning which proves to be very powerful. In this paper, we present a new corneal OCT image segmentation algorithm using Randomized Hough Transform. To the best of our knowledge, we developed the first automatic segmentation method for the six corneal microlayer interfaces. The proposed method includes a robust estimate of relative distances of inner corneal interfaces with respect to outer corneal interfaces. Also, it handles properly the correct ordering and the non-intersection of corneal microlayer interfaces. The proposed method was tested on 15 corneal OCT images that were randomly selected. OCT images were manually segmented by two trained operators for comparison. Comparison with the manual segmentation shows that the proposed method has mean segmentation error of 3.77 +/- 4.25 pixels across all interfaces which corresponds to 5.66 +/- 6.38 mu m. The mean segmentation error between the two manual operators is 4.07 +/- 4.71 pixels, which corresponds to 6.11 +/- 7.07 mu m. The proposed method takes a mean time of 2.59 +/- 0.06 seconds to segment six corneal interfaces.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Segmentation of Corneal Optical Coherence Tomography Images Using Graph Search and Radon Transform
    Elsawy, Amr
    Abdel-Mottaleb, Mohamed
    Abou Shousha, Mohamed
    MEDICAL IMAGING 2019: IMAGE PROCESSING, 2019, 10949
  • [2] Automatic Segmentation of Corneal Microlayers on Optical Coherence Tomography Images
    Elsawy, Amr
    Abdel-Mottaleb, Mohamed
    Sayed, Ibrahim-Osama
    Wen, Dan
    Roongpoovapatr, Vatookarn
    Eleiwa, Taher
    Sayed, Ahmed M.
    Raheem, Mariam
    Gameiro, Gustavo
    Abou Shousha, Mohamed
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (03):
  • [3] Graph-based segmentation of corneal epithelium and endothelium in Optical Coherence Tomography images
    Elsawy, Amr
    Roongpoovapatr, Vatookarn
    Eleiwa, Taher Kamel
    Gregori, Giovanni
    Abdel-Mottaleb, Mohamed
    Abou Shousha, Mohamed
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [4] Automated segmentation of optical coherence tomography images
    C.Kharmyssov
    高偉倫
    J.R.Kim
    ChineseOpticsLetters, 2019, 17 (01) : 66 - 71
  • [5] Automated segmentation of optical coherence tomography images
    Kharmyssov, C.
    Ko, M. W. L.
    Kim, J. R.
    CHINESE OPTICS LETTERS, 2019, 17 (01)
  • [6] Range image segmentation using Randomized Hough Transform
    Ding, YH
    Ping, XJ
    Hu, M
    Wang, D
    ICICS-PCM 2003, VOLS 1-3, PROCEEDINGS, 2003, : 807 - 811
  • [7] Enhancement of Corneal Visibility in Optical Coherence Tomography Images Using Corneal Adaptive Compensation
    Girard, Michael J. A.
    Ang, Marcus
    Chung, Cheuk Wang
    Farook, Mohamed
    Strouthidis, Nick
    Mehta, Jod S.
    Mari, Jean Martial
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2015, 4 (03): : 1 - 11
  • [8] Segmentation of Ophthalmic Optical Coherence Tomography Images Using Graph Cuts
    Li, Xiao T.
    Chiu, Stephanie J.
    Nicholas, Peter
    Toth, Cynthia A.
    Izatt, Joseph A.
    Farsiu, Sina
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [9] Enhancement of Corneal Visibility in Optical Coherence Tomography Images with Corneal Opacification
    Chung, Cheuk Wang
    Ang, Marcus
    Farook, Mohamed
    Strouthidis, Nicholas G.
    Mehta, Joddhbir S.
    Mari, Jean Martial
    Girard, Michael J. A.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2016, 5 (05):
  • [10] Automatic choroidal segmentation in optical coherence tomography images based on curvelet transform and graph theory
    Eghtedar, Reza Alizadeh
    Esmaeili, Mahdad
    Peyman, Alireza
    Akhlaghi, Mohammadreza
    Rasta, Seyed Hossein
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2023, 13 (02): : 92 - 100