Fire testing of electrical materials

被引:2
|
作者
Hirschler, MM [1 ]
机构
[1] GBH Int, Mill Valley, CA 94941 USA
关键词
cables; electrical materials; fire; fire hazard; fire test; flame spread; heat release; insulation; jacket; smoke obscuration;
D O I
10.1520/STP13464S
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In recent years electrical wire or cable insulation has been, once more, identified by NFPA statistics as a major material first ignited in residential fires (representing 7.6% of fires and 3.9% of fire fatalities in 1991-95) and the cause of 13% of catastrophic fires (1993-96). This highlights the need for renewed emphasis on fire testing of wires, cables and electrical materials. Cable fire tests can be subdivided into 5 categories: (a) Old fashioned small scale tests, which generally address only ignitability or flame spread, but the results of which are rarely meaningful in terms of real fire performance; (b) Vertical cable tray tests, of which there are a large variety, ranging in heat input from 20 kW up to 154 kW (in the case of riser cables), which address name spread, and sometimes also smoke and heat release: (c) The Steiner tunnel NFPA 262 (UL 910) test, which determines wind aided horizontal flame spread, and smoke release, under a very high heat input (ca. 90 kW), with a relatively small mass load of cables; and (d) Small scale cable tests, often originally designed for materials, directed at measuring fundamental fire properties, such as heat release or critical fluxes for ignition or name spread and thermal heating properties. (e) Tests for other cable fire properties, mainly smoke (obscuration, toxicity, corrosivity) and circuit integrity.
引用
收藏
页码:168 / 205
页数:38
相关论文
共 50 条
  • [41] Radiation-induced electrical degradation experiments in the Japan Materials Testing Reactor
    Farnum, EH
    Shikama, T
    Narui, M
    Sagawa, T
    Scarborough, K
    JOURNAL OF NUCLEAR MATERIALS, 1996, 228 (01) : 117 - 128
  • [42] MATERIALS TESTING IN THE ELECTRICAL/ELECTRONICS INDUSTRY: IT'S ROLE AND SOME METHODS.
    Zakraysek, Louis
    1600, (18):
  • [43] Materials and fire threat
    Sorathia, U
    Lyon, R
    Gann, RG
    Gritzo, L
    FIRE TECHNOLOGY, 1997, 33 (03) : 260 - 275
  • [44] MATERIALS AND FIRE HAZARDS
    TAYLOR, PE
    POST OFFICE ELECTRICAL ENGINEERS JOURNAL, 1966, 59 : 16 - &
  • [45] PLASTIC MATERIALS AND FIRE
    GARNIER, R
    CONSO, F
    EFTHYNIOU, ML
    RIBOULET, G
    BAROIS, A
    GAULTIER, M
    VETERINARY AND HUMAN TOXICOLOGY, 1979, 21 : 120 - 121
  • [46] Materials and fire threat
    Sorathia, U
    Lyon, R
    Gann, R
    Gritzo, L
    SAMPE JOURNAL, 1996, 32 (03) : 8 - 15
  • [47] Materials and Fire Threat
    Usman Sorathia
    Richard Lyon
    Richard G. Gann
    Louis Gritzo
    Fire Technology, 1997, 33 : 260 - 275
  • [48] MATERIALS AND TESTING OF MATERIALS
    JORGENS, H
    BRENNSTOFF-WARME-KRAFT, 1978, 30 (04): : 170 - 173
  • [49] MATERIALS AND TESTING OF MATERIALS
    JORGENS, H
    BRENNSTOFF-WARME-KRAFT, 1982, 34 (04): : 244 - 247
  • [50] MATERIALS AND TESTING OF MATERIALS
    JORGENS, H
    BRENNSTOFF-WARME-KRAFT, 1980, 32 (04): : 186 - 189