Fire testing of electrical materials

被引:2
|
作者
Hirschler, MM [1 ]
机构
[1] GBH Int, Mill Valley, CA 94941 USA
关键词
cables; electrical materials; fire; fire hazard; fire test; flame spread; heat release; insulation; jacket; smoke obscuration;
D O I
10.1520/STP13464S
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In recent years electrical wire or cable insulation has been, once more, identified by NFPA statistics as a major material first ignited in residential fires (representing 7.6% of fires and 3.9% of fire fatalities in 1991-95) and the cause of 13% of catastrophic fires (1993-96). This highlights the need for renewed emphasis on fire testing of wires, cables and electrical materials. Cable fire tests can be subdivided into 5 categories: (a) Old fashioned small scale tests, which generally address only ignitability or flame spread, but the results of which are rarely meaningful in terms of real fire performance; (b) Vertical cable tray tests, of which there are a large variety, ranging in heat input from 20 kW up to 154 kW (in the case of riser cables), which address name spread, and sometimes also smoke and heat release: (c) The Steiner tunnel NFPA 262 (UL 910) test, which determines wind aided horizontal flame spread, and smoke release, under a very high heat input (ca. 90 kW), with a relatively small mass load of cables; and (d) Small scale cable tests, often originally designed for materials, directed at measuring fundamental fire properties, such as heat release or critical fluxes for ignition or name spread and thermal heating properties. (e) Tests for other cable fire properties, mainly smoke (obscuration, toxicity, corrosivity) and circuit integrity.
引用
收藏
页码:168 / 205
页数:38
相关论文
共 50 条
  • [31] A Review: Application of Terahertz Nondestructive Testing Technology in Electrical Insulation Materials
    Guo, Chenjun
    Xu, Wenlong
    Cai, Mingming
    Duan, Shufan
    Fu, Jianbiao
    Zhang, Xinlong
    IEEE ACCESS, 2022, 10 : 121547 - 121560
  • [32] Sheath materials for direct electrical heating cable - Long term testing
    Melve, Bjorn
    Proceedings of the 26th International Conference on Offshore Mechanics and Arctic Engineering, Vol 4, 2007, : 91 - 97
  • [33] Reliability Testing by Mechanical and Electrical Characterization of Flexible and Stretchable Interconnect Materials
    Nandy, Mayukh
    Wu, Yanze
    Houghton, Todd
    Yu, Hongbin
    IEEE 71ST ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC 2021), 2021, : 1744 - 1748
  • [34] Investigation of electrical fire
    Jacquat, A
    Martin, JC
    FORENSIC SCIENCE INTERNATIONAL, 2003, 136 : 145 - 146
  • [35] Technical note: The fire performance of electrical insulating materials used in fluorescent lighting fixtures
    Zicherman, J
    FIRE AND MATERIALS, 2001, 25 (05) : 209 - 213
  • [36] Elevated temperature adhesion testing of spray-applied fire-resistive materials
    White, Christopher C.
    Tan, Kar Tean
    Hunston, Donald L.
    Byrd, Eric W.
    FIRE AND MATERIALS, 2016, 40 (04) : 519 - 534
  • [37] Fire testing at Dunlop
    Birch, S
    AEROSPACE ENGINEERING, 2003, 23 (08) : 6 - 6
  • [38] Fire barrier testing
    不详
    NUCLEAR PLANT JOURNAL, 1996, 14 (02) : 11 - 11
  • [39] Modeling of fire exposure in facade fire testing
    Anderson, J.
    Bostroem, L.
    McNamee, R. Jansson
    Milovanovic, B.
    FIRE AND MATERIALS, 2018, 42 (05) : 475 - 483
  • [40] THE ROLE OF FIRE TESTING IN THE USE OF FIRE RETARDANTS
    BECKER, WHK
    POLYMER DEGRADATION AND STABILITY, 1990, 30 (01) : 141 - 152