Femoral head material loss at the head-neck junction in total hip arthroplasty: the effect of head size, stem material and stem offset

被引:7
|
作者
Valente, Giuseppe [1 ]
Lanting, Brent [1 ]
MacDonald, Steven [1 ]
Teeter, Matthew G. [2 ,3 ]
Van Citters, Douglas [4 ]
Howard, James [1 ]
机构
[1] Western Univ, London Hlth Sci Ctr, Schulich Sch Med & Dent, Div Orthopaed Surg,Dept Surg,Univ Hosp, London, ON, Canada
[2] Western Univ, Schulich Sch Med & Dent, Dept Med Biophys, London, ON, Canada
[3] Lawson Hlth Res Inst, Surg Innovat Program, London, ON, Canada
[4] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
关键词
Corrosion; metal-on-polyethylene; taper; total hip arthroplasty; trunnion; trunnionosis; TAPER JUNCTION; CORROSION; METAL; TRUNNIONOSIS; COMPONENTS; INTERFACE;
D O I
10.1177/1120700018814473
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Material loss at the head-neck junction in total hip arthroplasty may cause adverse clinical symptoms and implant failure. The purpose of this study was to quantitatively examine the effects of head size, stem material and stem offset on material loss of the head-neck taper interface of a single trunnion design in retrieval implants of metal on polyethylene bearing surfaces. Methods: A retrieval study was performed to identify all 28-mm and 32-mm femoral heads from a single implant/taper design implanted for >2 years. This included n = 56 of the 28-mm heads and n = 23 of the 32-mm heads. The 28-mm femoral heads were matched to 32-mm femoral heads based on time in vivo and head length. A coordinate measuring machine was used to determine maximum linear corrosion depth (MLD). Differences in MLD for head diameter, stem material, and stem offset were determined. Results: There were no differences between groups for age, gender, BMI, or implantation time. There was no difference in MLD between 28 mm and 32 mm matched paired head diameters (p = 0.59). There was also no difference in MLD between titanium or cobalt-chromium stems (p = 0.79), and regular or high-offset stems (p = 0.95). Conclusion: There is no statistical difference in femoral head MLD at the head-neck junction in THA between 28-mm and 32-mm matched paired femoral heads, similar or mixed alloy coupled femoral head stem constructs, and regular or high offset stems.
引用
收藏
页码:647 / 651
页数:5
相关论文
共 50 条
  • [1] Effect of Femoral Head Material, Surgeon Experience, and Assembly Technique on Simulated Head-Neck Total Hip Arthroplasty Impaction Forces
    Godoy, Michael
    Sipek, Kirsten
    Gustafson, Jonathan A.
    Yuh, Catherine
    Levine, Brett R.
    Pourzal, Robin
    Lundberg, Hannah J.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (02): : 507 - 513.e1
  • [2] Corrosion of the Head-neck Junction After Total Hip Arthroplasty
    Jennings, Jason M.
    Dennis, Douglas A.
    Yang, Charlie C.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (06) : 349 - 356
  • [3] Head-neck taper corrosion following total hip arthroplasty with Stryker Meridian stem
    Patel, Sonika
    Talmo, Carl T.
    Nandi, Sumon
    HIP INTERNATIONAL, 2016, 26 (06) : E49 - E51
  • [4] Effect of collapse on the deformity of the femoral head-neck junction in osteonecrosis of the femoral head
    Kubo, Yusuke
    Motomura, Goro
    Ikemura, Satoshi
    Sonoda, Kazuhiko
    Yamamoto, Takuaki
    Nakashima, Yasuharu
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (07) : 933 - 938
  • [5] Head-neck modularity for total hip arthroplasty - Is it necessary?
    Hozack, WJ
    Mesa, JJ
    Rothman, RF
    JOURNAL OF ARTHROPLASTY, 1996, 11 (04): : 397 - 399
  • [6] Reduced head-neck offset in nontraumatic osteonecrosis of the femoral head
    Fraitzl, Christian R.
    Kappe, Thomas
    Brugger, Annina
    Billich, Christian
    Reichel, Heiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (08) : 1055 - 1060
  • [7] Femoral Head-neck Junction Deformity is Related to Osteoarthritis of the Hip
    Melo Barros, Hilton Jose
    Camanho, Gilberto Luis
    Bernabe, Antonio Carlos
    Rodrigues, Marcelo Bordalo
    Garcez Leme, Luiz Eugenio
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (07) : 1920 - 1925
  • [8] Parametric analysis of the effect of impaction load on the stability of head-neck junction in total hip arthroplasty
    Zhang, Guoxian
    Yang, Shu
    Cui, Wen
    Peng, Xing
    Zhang, Xiaogang
    Zhang, Yali
    Li, Junyan
    Jin, Zhongmin
    CLINICAL BIOMECHANICS, 2022, 94
  • [9] Contribution of the Bioball™ head-neck adapter to the restoration of femoral offset in hip revision arthroplasty with retention of a well-fixed cup and stem
    Chimeno, Clara
    Fernandez-Valencia, Jenaro angel
    Alias, Alfonso
    Serra, Adria
    Postnikov, Yury
    Combalia, Andres
    Munoz-Mahamud, Ernesto
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (09) : 2245 - 2251
  • [10] Hip Flexion After Birmingham Hip Resurfacing Role of Cup Anteversion, Anterior Femoral Head-Neck Offset, and Head-Neck Ratio
    Malviya, Ajay
    Lingard, Elizabeth A.
    Malik, Atul
    Bowman, Russell
    Holland, James P.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03): : 387 - 391